Venous-phase chest CT with reduced contrast medium dose: Utilization of spectral low keV monoenergetic images improves image quality. Issue 122 (January 2020)
- Record Type:
- Journal Article
- Title:
- Venous-phase chest CT with reduced contrast medium dose: Utilization of spectral low keV monoenergetic images improves image quality. Issue 122 (January 2020)
- Main Title:
- Venous-phase chest CT with reduced contrast medium dose: Utilization of spectral low keV monoenergetic images improves image quality
- Authors:
- Hickethier, Tilman
Kroeger, Jan Robert
Lennartz, Simon
Doerner, Jonas
Maintz, David
Chang, De-Hua - Abstract:
- Highlights: Low keV monoenergetic images of Dual Energy CT increase iodine-based image contrast. Image quality is improved by monoenergetic images in reduced contrast dose CT scans. With monoenergetic images no reduced contrast dose CT scan was rated non-diagnostic. Monoenergetic images may enable new indications for reduced contrast dose CT scans. Abstract: Purpose: Intravenous contrast administration is crucial in many CT examinations but also poses a potential risk to the patient. Monoenergetic images (MonoE) of dual-energy CT systems can virtually increase iodine attenuation and might improve image quality (IQ) if contrast dose is reduced. In this study, we investigated the influence of MonoE on lymph node (LN) delineation and IQ in chest CT examinations with significantly reduced contrast dose (50 %) of a novel dual-layer CT (DLCT). Method: 30 patients with clinically indicated reduced contrast dose underwent venous-phase chest DLCT scans. Conventional polyenergetic (PolyE) and MonoE images at 40 keV were calculated. The contrast difference of hilar lymph nodes (LN-CD) to the adjacent right pulmonary artery, their signal-to-noise (SNR) and contrast-to-noise-ratio (CNR) were determined. Subjective IQ was evaluated by 2 readers with respect to LN delineation and overall contrast enhancement (CE) using a 5-point-Likert-scale. Results: LN-CD, SNR and CNR were significantly higher in MonoE than in PolyE images (LN-CD 92.3 ± 37.9 vs. 33.1 ± 14.5 HU, SNR 8.4 ± 3.4 vs.Highlights: Low keV monoenergetic images of Dual Energy CT increase iodine-based image contrast. Image quality is improved by monoenergetic images in reduced contrast dose CT scans. With monoenergetic images no reduced contrast dose CT scan was rated non-diagnostic. Monoenergetic images may enable new indications for reduced contrast dose CT scans. Abstract: Purpose: Intravenous contrast administration is crucial in many CT examinations but also poses a potential risk to the patient. Monoenergetic images (MonoE) of dual-energy CT systems can virtually increase iodine attenuation and might improve image quality (IQ) if contrast dose is reduced. In this study, we investigated the influence of MonoE on lymph node (LN) delineation and IQ in chest CT examinations with significantly reduced contrast dose (50 %) of a novel dual-layer CT (DLCT). Method: 30 patients with clinically indicated reduced contrast dose underwent venous-phase chest DLCT scans. Conventional polyenergetic (PolyE) and MonoE images at 40 keV were calculated. The contrast difference of hilar lymph nodes (LN-CD) to the adjacent right pulmonary artery, their signal-to-noise (SNR) and contrast-to-noise-ratio (CNR) were determined. Subjective IQ was evaluated by 2 readers with respect to LN delineation and overall contrast enhancement (CE) using a 5-point-Likert-scale. Results: LN-CD, SNR and CNR were significantly higher in MonoE than in PolyE images (LN-CD 92.3 ± 37.9 vs. 33.1 ± 14.5 HU, SNR 8.4 ± 3.4 vs. 4.0 ± 1.2, CNR 9.2 ± 6.3 vs. 2.6 ± 1.5; all p < 0.01). The LN delineation (3.7 ± 0.9 vs.1.8 ± 0.7; p < 0.01) and the CE (3.9 ± 0.7 vs. 2.3 ± 0.7; p < 0.01) were rated significantly better for MonoE than for PolyE images. There was no MonoE examination classified as non-diagnostic. Conclusions: Subjective and objective IQ parameters can be significantly improved for venous-phase chest CT examinations with reduced contrast doses by utilization of low-keV MonoE reconstructions. All MonoE images provided sufficient overall CE and therefore reduced contrast doses might be considered in a wider range of DLCT examinations and patients. … (more)
- Is Part Of:
- European journal of radiology. Issue 122(2020)
- Journal:
- European journal of radiology
- Issue:
- Issue 122(2020)
- Issue Display:
- Volume 122, Issue 122 (2020)
- Year:
- 2020
- Volume:
- 122
- Issue:
- 122
- Issue Sort Value:
- 2020-0122-0122-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01
- Subjects:
- Dual energy -- Dual layer -- CT -- Chest -- Contrast media reduction -- Low contrast agent dose
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2019.108756 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12515.xml