Clinical experience with lung-specific electromagnetic transponders for real-time tumor tracking in lung stereotactic body radiotherapy. (October 2019)
- Record Type:
- Journal Article
- Title:
- Clinical experience with lung-specific electromagnetic transponders for real-time tumor tracking in lung stereotactic body radiotherapy. (October 2019)
- Main Title:
- Clinical experience with lung-specific electromagnetic transponders for real-time tumor tracking in lung stereotactic body radiotherapy
- Authors:
- Jaccard, Maud
Champion, Ambroise
Dubouloz, Angèle
Picardi, Cristina
Plojoux, Jérôme
Soccal, Paola
Miralbell, Raymond
Dipasquale, Giovanna
Caparrotti, Francesca - Abstract:
- Highlights: 7 patients were implanted with lung-specific electromagnetic transponders (EMT). We report no complications from implantation and no migration of the EMT. 7 non-small cell lung cancer patients underwent SBRT using EMT real-time tracking. SBRT was delivered in free-breathing (FB) or in deep inspiration breath-hold (DIBH). Abstract: Background and purposes: Motion management is crucial for optimal stereotactic body radiotherapy (SBRT) of moving targets. We aimed to describe our clinical experience with real-time tracking of lung-specific electromagnetic transponders (EMTs) for SBRT of early stage non-small cell lung cancer in free-breathing (FB) or deep inspiration breath-hold (DIBH). Material and methods: Seven patients were implanted with EMTs. Simulation for SBRT was performed in FB and in DIBH. We prescribed 60 Gy in 3, 5 or 8 fractions to the tumor and delivered SBRT with volumetric modulated arcs and a 6 MV flattening filter free photon beam. Patients' setup at the linac was performed using EMT positions and cone-beam CT (CBCT) verification. Four patients were treated in DIBH because of a dosimetric benefit. We analysed patient alignment and treatment delivery parameters using DIBH or FB and EMT real-time tracking. Results: There were no complications from the EMT implantation. Visual inspection of CBCT before and/or after SBRT revealed good alignment of structures and EMTs. The median setup time was 9.8 min (range: 4.6–34.1 min) and the median session timeHighlights: 7 patients were implanted with lung-specific electromagnetic transponders (EMT). We report no complications from implantation and no migration of the EMT. 7 non-small cell lung cancer patients underwent SBRT using EMT real-time tracking. SBRT was delivered in free-breathing (FB) or in deep inspiration breath-hold (DIBH). Abstract: Background and purposes: Motion management is crucial for optimal stereotactic body radiotherapy (SBRT) of moving targets. We aimed to describe our clinical experience with real-time tracking of lung-specific electromagnetic transponders (EMTs) for SBRT of early stage non-small cell lung cancer in free-breathing (FB) or deep inspiration breath-hold (DIBH). Material and methods: Seven patients were implanted with EMTs. Simulation for SBRT was performed in FB and in DIBH. We prescribed 60 Gy in 3, 5 or 8 fractions to the tumor and delivered SBRT with volumetric modulated arcs and a 6 MV flattening filter free photon beam. Patients' setup at the linac was performed using EMT positions and cone-beam CT (CBCT) verification. Four patients were treated in DIBH because of a dosimetric benefit. We analysed patient alignment and treatment delivery parameters using DIBH or FB and EMT real-time tracking. Results: There were no complications from the EMT implantation. Visual inspection of CBCT before and/or after SBRT revealed good alignment of structures and EMTs. The median setup time was 9.8 min (range: 4.6–34.1 min) and the median session time was 14.7 min (range: 7.3–36.5 min). EMT positions in lungs remained stable during overall treatment and allowed real-time tracking both in FB and in DIBH SBRT. The treatment beam was gated when EMT centroid position exceeded tolerance thresholds ensuring correct delivery of radiation to the tumor. Conclusion: Using EMTs for real-time tracking of tumor motion during lung SBRT proved to be safe, accurate and easy to integrate clinically for treatments in FB or DIBH. … (more)
- Is Part Of:
- Physics and imaging in radiation oncology. Volume 12(2019)
- Journal:
- Physics and imaging in radiation oncology
- Issue:
- Volume 12(2019)
- Issue Display:
- Volume 12, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 12
- Issue:
- 2019
- Issue Sort Value:
- 2019-0012-2019-0000
- Page Start:
- 30
- Page End:
- 37
- Publication Date:
- 2019-10
- Subjects:
- Lung SBRT -- Real-time tracking -- Electromagnetic transponder -- Intra-fraction motion -- Deep inspiration breath-hold
Radiotherapy -- Periodicals
Radiation dosimetry -- Periodicals
Cancer -- Imaging -- Periodicals
Oncology -- Periodicals
615.842 - Journal URLs:
- http://www.sciencedirect.com/ ↗
https://www.journals.elsevier.com/physics-and-imaging-in-radiation-oncology/ ↗ - DOI:
- 10.1016/j.phro.2019.11.002 ↗
- Languages:
- English
- ISSNs:
- 2405-6316
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12518.xml