Calculating dose from a 2.5 MV imaging beam using a commercial treatment planning system. Issue 12 (1st November 2019)
- Record Type:
- Journal Article
- Title:
- Calculating dose from a 2.5 MV imaging beam using a commercial treatment planning system. Issue 12 (1st November 2019)
- Main Title:
- Calculating dose from a 2.5 MV imaging beam using a commercial treatment planning system
- Authors:
- Ferris, William S.
Culberson, Wesley S.
Anderson, Daniel R.
Labby, Zacariah E. - Abstract:
- Abstract: Patient dose from 2.5 MV images on the TrueBeam linear accelerator is not easily quantified, primarily because this beam energy is not normally modeled by commercial treatment planning systems. In this work we present the feasibility of using the Eclipse® treatment planning system to model this beam. The Acuros XB and the AAA dose calculation algorithms were tested. Profiles, PDDs, and output factors were measured for the 2.5 MV unflattened imaging beam and used for beam modeling. The algorithms were subsequently verified using MPPG 5.a guidelines. Calculated doses with both algorithms agreed with the measurement data to within the following criteria recommended for conventional therapeutic MV beams: 2% local dose‐difference in the high‐dose region, 3% global difference in the low‐dose region, 3 mm distance to agreement in the penumbra, and a gamma pass rate of >95% for 3%/3 mm criteria. Acuros was able to accurately calculate dose through cork and bone‐equivalent heterogeneities. AAA was able to accurately calculate dose through the bone‐equivalent heterogeneity but did not pass within the recommended criteria for the cork heterogeneity. For the 2.5 MV imaging beam, both the AAA and Acuros algorithms provide calculated doses that agree with measured results well within the 20% criteria for imaging beams recommended by AAPM TG‐180.
- Is Part Of:
- Journal of applied clinical medical physics. Volume 20:Issue 12(2019)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 20:Issue 12(2019)
- Issue Display:
- Volume 20, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 12
- Issue Sort Value:
- 2019-0020-0012-0000
- Page Start:
- 25
- Page End:
- 35
- Publication Date:
- 2019-11-01
- Subjects:
- 2.5 MV imaging dose -- AAA -- Acuros -- Eclipse -- TrueBeam
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12756 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12497.xml