New Insights into the Effects of Chronic Kidney Failure and Dialysate Exposure on the Peritoneum. Issue 6 (November 2016)
- Record Type:
- Journal Article
- Title:
- New Insights into the Effects of Chronic Kidney Failure and Dialysate Exposure on the Peritoneum. Issue 6 (November 2016)
- Main Title:
- New Insights into the Effects of Chronic Kidney Failure and Dialysate Exposure on the Peritoneum
- Authors:
- Vlahu, Carmen A.
Aten, Jan
de Graaff, Marijke
van Veen, Henk
Everts, Vincent
de Waart, Dirk R.
Struijk, Dirk G.
Krediet, Raymond T. - Abstract:
- Introduction: Chronic uremia and the exposure to dialysis solutions during peritoneal dialysis (PD) induce peritoneal alterations. Using a long-term peritoneal exposure model, we compared the effects of chronic kidney failure (CKD) itself and exposure to either a 'conventional' or a 'biocompatible' dialysis solution on peritoneal morphology and function. Methods: Wistar rats (Harlan, Zeist, the Netherlands) were grouped into: normal kidney function (NKF), CKD induced by 70% nephrectomy, CKD receiving daily peritoneal infusions with 3.86% glucose Dianeal (CKDD), or Physioneal (both solutions from Baxter Healthcare, Castlebar, Ireland) (CKDP). At 16 weeks, a peritoneal function test was performed, and histology, ultrastructure, and hydroxyproline content of peritoneal tissue were assessed. Results: Comparing CKD with NKF, peritoneal transport rates were higher, mesothelial cells (MC) displayed increased number of microvilli, blood and lymph vasculature expanded, vascular basal lamina appeared thicker, with limited areas of duplication, and fibrosis had developed. All alterations, except lymphangiogenesis, were enhanced by exposure to both dialysis fluids. Distinct MC alterations were observed in CKDD and CKDP, the latter displaying prominent basolateral protrusions. In addition, CKDP was associated with a trend towards less fibrosis compared to CKDD. Conclusions: Chronic kidney failure itself induced peritoneal alterations, which were in part augmented by exposure toIntroduction: Chronic uremia and the exposure to dialysis solutions during peritoneal dialysis (PD) induce peritoneal alterations. Using a long-term peritoneal exposure model, we compared the effects of chronic kidney failure (CKD) itself and exposure to either a 'conventional' or a 'biocompatible' dialysis solution on peritoneal morphology and function. Methods: Wistar rats (Harlan, Zeist, the Netherlands) were grouped into: normal kidney function (NKF), CKD induced by 70% nephrectomy, CKD receiving daily peritoneal infusions with 3.86% glucose Dianeal (CKDD), or Physioneal (both solutions from Baxter Healthcare, Castlebar, Ireland) (CKDP). At 16 weeks, a peritoneal function test was performed, and histology, ultrastructure, and hydroxyproline content of peritoneal tissue were assessed. Results: Comparing CKD with NKF, peritoneal transport rates were higher, mesothelial cells (MC) displayed increased number of microvilli, blood and lymph vasculature expanded, vascular basal lamina appeared thicker, with limited areas of duplication, and fibrosis had developed. All alterations, except lymphangiogenesis, were enhanced by exposure to both dialysis fluids. Distinct MC alterations were observed in CKDD and CKDP, the latter displaying prominent basolateral protrusions. In addition, CKDP was associated with a trend towards less fibrosis compared to CKDD. Conclusions: Chronic kidney failure itself induced peritoneal alterations, which were in part augmented by exposure to glucose-based dialysis solutions. Overall, the conventional and biocompatible solutions had similar long-term effects on the peritoneum. Importantly, the latter may attenuate the development of fibrosis. … (more)
- Is Part Of:
- Peritoneal dialysis international. Volume 36:Issue 6(2016)
- Journal:
- Peritoneal dialysis international
- Issue:
- Volume 36:Issue 6(2016)
- Issue Display:
- Volume 36, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 36
- Issue:
- 6
- Issue Sort Value:
- 2016-0036-0006-0000
- Page Start:
- 614
- Page End:
- 622
- Publication Date:
- 2016-11
- Subjects:
- Peritoneal dialysis -- electron microscopy -- bio-compatible dialysis solutions -- lymphangiogenesis -- stereology -- image analysis
Peritoneal dialysis -- Periodicals
Continuous ambulatory peritoneal dialysis -- Periodicals
617.461059 - Journal URLs:
- http://www.pdiconnect.com/ ↗
https://journals.sagepub.com/home/ptd ↗ - DOI:
- 10.3747/pdi.2015.00204 ↗
- Languages:
- English
- ISSNs:
- 0896-8608
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 12489.xml