New parameters of ultrafast dynamic contrast‐enhanced breast MRI using compressed sensing. Issue 1 (18th June 2019)
- Record Type:
- Journal Article
- Title:
- New parameters of ultrafast dynamic contrast‐enhanced breast MRI using compressed sensing. Issue 1 (18th June 2019)
- Main Title:
- New parameters of ultrafast dynamic contrast‐enhanced breast MRI using compressed sensing
- Authors:
- Honda, Maya
Kataoka, Masako
Onishi, Natsuko
Iima, Mami
Ohashi, Akane
Kanao, Shotaro
Nickel, Marcel Dominik
Toi, Masakazu
Togashi, Kaori - Abstract:
- Abstract : Background: Ultrafast dynamic contrast‐enhanced (UF‐DCE) breast MRI is considered a promising method of accelerated breast MRI. However, the value of new kinetic parameters derived from UF‐DCE need clinical evaluation. Purpose: To evaluate the diagnostic performance of the maximum slope (MS), time to enhancement (TTE), and time interval between arterial and venous visualization (AVI) derived from UF‐DCE MRI using compressed sensing (CS). Study Type: Retrospective. Population: Seventy‐five patients with histologically proven breast lesions. The total number of analyzed lesions was 90 (61 malignant and 29 benign). Field Strength/Sequence: 3T MRI with UF‐DCE MRI based on the 3D gradient‐echo volumetric interpolated breath‐hold examination (VIBE) sequence using incoherent k ‐space sampling combined with a CS reconstruction followed by conventional DCE MRI. Assessment: The diagnostic performance of the MS, TTE, AVI, and conventional kinetic analysis was analyzed and compared with histology. Statistical Tests: Wilcoxon rank sum test, receiver operating characteristic analysis. Results: The MS was larger and the TTE and AVI were smaller for malignant lesions compared with benign lesions: MS: 29.3%/s and 18.4%/s ( P < 0.001), TTE: 7.0 and 12.0 seconds ( P < 0.001), AVI: 2.7 and 4.4 frames ( P = 0.006) for malignant and benign lesions. The discriminating power of the MS (area under the curve [AUC], 0.76) was slightly better than that of conventional kinetic analysisAbstract : Background: Ultrafast dynamic contrast‐enhanced (UF‐DCE) breast MRI is considered a promising method of accelerated breast MRI. However, the value of new kinetic parameters derived from UF‐DCE need clinical evaluation. Purpose: To evaluate the diagnostic performance of the maximum slope (MS), time to enhancement (TTE), and time interval between arterial and venous visualization (AVI) derived from UF‐DCE MRI using compressed sensing (CS). Study Type: Retrospective. Population: Seventy‐five patients with histologically proven breast lesions. The total number of analyzed lesions was 90 (61 malignant and 29 benign). Field Strength/Sequence: 3T MRI with UF‐DCE MRI based on the 3D gradient‐echo volumetric interpolated breath‐hold examination (VIBE) sequence using incoherent k ‐space sampling combined with a CS reconstruction followed by conventional DCE MRI. Assessment: The diagnostic performance of the MS, TTE, AVI, and conventional kinetic analysis was analyzed and compared with histology. Statistical Tests: Wilcoxon rank sum test, receiver operating characteristic analysis. Results: The MS was larger and the TTE and AVI were smaller for malignant lesions compared with benign lesions: MS: 29.3%/s and 18.4%/s ( P < 0.001), TTE: 7.0 and 12.0 seconds ( P < 0.001), AVI: 2.7 and 4.4 frames ( P = 0.006) for malignant and benign lesions. The discriminating power of the MS (area under the curve [AUC], 0.76) was slightly better than that of conventional kinetic analysis (AUC, 0.69) and comparable to that of the TTE and AVI (AUC, 0.78 and 0.76 for TTE and AVI, respectively). Invasive lobular carcinoma had smaller MS (21.8%/s) among malignant lesions (29.3%/s). Data Conclusion: The MS, TTE, and AVI can be used to evaluate breast lesions with clinical performance equivalent to that of conventional kinetic analysis. These parameters vary among histologies. Level of Evidence: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:164–174. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 51:Issue 1(2020)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 51:Issue 1(2020)
- Issue Display:
- Volume 51, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 51
- Issue:
- 1
- Issue Sort Value:
- 2020-0051-0001-0000
- Page Start:
- 164
- Page End:
- 174
- Publication Date:
- 2019-06-18
- Subjects:
- compressed sensing -- ultrafast imaging -- magnetic resonance imaging -- kinetic parameter -- breast diseases
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.26838 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12479.xml