Catheter‐induced premature ventricular complexes (PVCs) may aid in the determination of optimal timing for clinical PVC ablation. Issue 12 (17th November 2019)
- Record Type:
- Journal Article
- Title:
- Catheter‐induced premature ventricular complexes (PVCs) may aid in the determination of optimal timing for clinical PVC ablation. Issue 12 (17th November 2019)
- Main Title:
- Catheter‐induced premature ventricular complexes (PVCs) may aid in the determination of optimal timing for clinical PVC ablation
- Authors:
- Demir, Serdar
Akgun, Taylan
Gulsen, Kamil
Kup, Ayhan
Uslu, Abdulkadir
Kayan, Fethullah
Kepez, Alper - Abstract:
- Abstract: Background: The aim of the present study is to evaluate whether catheter‐induced premature ventricular complexes (PVCs) produced at the presumptive ablation site may aid in the identification of the optimal timing of the earliest local activation for the successful ablation of clinical PVCs. Methods: Sixty‐three consecutive patients (35 males, age: 53.5 ± 14.4 years) without any exclusion criteria who had undergone PVC ablation between 1 July 2018 and 1 July 2019 constituted our study population. The time interval between the beginning of the EGM and the beginning of the QRS of each catheter‐induced PVC (Cath EGM‐ECG) and the time interval between the beginning of the EGM of clinical PVCs at the earliest site and the beginning of the QRS of clinical PVCs (PVC earliest EGM‐ECG) were noted for each patient. The value of Cath EGM‐ECG as a reference for procedural success of ablation was evaluated by examining the relationship between Cath EGM‐ECG and PVC earliest EGM‐ECG. Results: Fifty‐two patients had successful ablation, and 43 of them (82.7%) had PVC earliest EGM‐ECG values greater than or equal to Cath EGM‐ECG. Eleven patients had procedural failure, and all of them had PVC earliest EGM‐ECG values lower than Cath EGM‐ECG. A PVC earliest EGM‐ECG value –1.5 ms greater than Cath EGM‐ECG predicted successful ablation with a sensitivity of 90.4% and a specificity of 100.0% in the general patient population. Conclusion: Cath EGM‐ECG seems to serve as a reliable guideAbstract: Background: The aim of the present study is to evaluate whether catheter‐induced premature ventricular complexes (PVCs) produced at the presumptive ablation site may aid in the identification of the optimal timing of the earliest local activation for the successful ablation of clinical PVCs. Methods: Sixty‐three consecutive patients (35 males, age: 53.5 ± 14.4 years) without any exclusion criteria who had undergone PVC ablation between 1 July 2018 and 1 July 2019 constituted our study population. The time interval between the beginning of the EGM and the beginning of the QRS of each catheter‐induced PVC (Cath EGM‐ECG) and the time interval between the beginning of the EGM of clinical PVCs at the earliest site and the beginning of the QRS of clinical PVCs (PVC earliest EGM‐ECG) were noted for each patient. The value of Cath EGM‐ECG as a reference for procedural success of ablation was evaluated by examining the relationship between Cath EGM‐ECG and PVC earliest EGM‐ECG. Results: Fifty‐two patients had successful ablation, and 43 of them (82.7%) had PVC earliest EGM‐ECG values greater than or equal to Cath EGM‐ECG. Eleven patients had procedural failure, and all of them had PVC earliest EGM‐ECG values lower than Cath EGM‐ECG. A PVC earliest EGM‐ECG value –1.5 ms greater than Cath EGM‐ECG predicted successful ablation with a sensitivity of 90.4% and a specificity of 100.0% in the general patient population. Conclusion: Cath EGM‐ECG seems to serve as a reliable guide for finding the optimal timing of the earliest site for successful PVC ablation. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 42:Issue 12(2019)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 42:Issue 12(2019)
- Issue Display:
- Volume 42, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 42
- Issue:
- 12
- Issue Sort Value:
- 2019-0042-0012-0000
- Page Start:
- 1573
- Page End:
- 1578
- Publication Date:
- 2019-11-17
- Subjects:
- activation mapping -- premature ventricular complex -- radiofrequency ablation
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.13833 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12477.xml