Impact of monitoring on detection of arrhythmia recurrences in the ESC-EHRA EORP atrial fibrillation ablation long-term registry. Issue 12 (13th August 2019)
- Record Type:
- Journal Article
- Title:
- Impact of monitoring on detection of arrhythmia recurrences in the ESC-EHRA EORP atrial fibrillation ablation long-term registry. Issue 12 (13th August 2019)
- Main Title:
- Impact of monitoring on detection of arrhythmia recurrences in the ESC-EHRA EORP atrial fibrillation ablation long-term registry
- Authors:
- Balabanski, Tosho
Brugada, Josep
Arbelo, Elena
Laroche, Cécile
Maggioni, Aldo
Blomström-Lundqvist, Carina
Kautzner, Josef
Tavazzi, Luigi
Tritto, Massimo
Kulakowski, Piotr
Kalejs, Oskars
Forster, Tamas
Villalobos, Federico Segura
Dagres, Nikolaos - Abstract:
- Abstract: Aims: Monitoring of patients after ablation had wide variations in the ESC-EHRA atrial fibrillation ablation long-term (AFA-LT) registry. We aimed to compare four different monitoring strategies after catheter AF ablation. Methods and results: The ESC-EHRA AFA-LT registry included 3593 patients who underwent ablation. Arrhythmia monitoring during follow-up was performed by 12-lead electrocardiogram (ECG), Holter ECG, trans-telephonic ECG monitoring (TTMON), or an implanted cardiac monitoring (ICM) system. Patients were selected to a given monitoring group according to the most extensive ECG tool used in each of them. Comparison of the probability of freedom from recurrences was performed by censored log-rank test and presented by Kaplan–Meier curves. The rhythm monitoring methods were used among 2658 patients: ECG ( N = 578), Holter ECG ( N = 1874), TTMON ( N = 101), and ICM ( N = 105). A total of 767 of 2658 patients (28.9%) had AF recurrences during follow-up. Censored log-rank test discovered a lower probability of freedom from relapses, which was detected with ICM compared to TTMON, ECG, and Holter ECG ( P < 0.001). The rate of freedom from AF recurrences was 50.5% among patients using the ICM while it was 65.4%, 70.6%, and 72.8% using the TTMON, ECG, and Holter ECG, respectively. Conclusion: Comparing all main electrocardiographic monitoring methods in a large patient sample, our results suggest that post-ablation recurrences of AF are significantlyAbstract: Aims: Monitoring of patients after ablation had wide variations in the ESC-EHRA atrial fibrillation ablation long-term (AFA-LT) registry. We aimed to compare four different monitoring strategies after catheter AF ablation. Methods and results: The ESC-EHRA AFA-LT registry included 3593 patients who underwent ablation. Arrhythmia monitoring during follow-up was performed by 12-lead electrocardiogram (ECG), Holter ECG, trans-telephonic ECG monitoring (TTMON), or an implanted cardiac monitoring (ICM) system. Patients were selected to a given monitoring group according to the most extensive ECG tool used in each of them. Comparison of the probability of freedom from recurrences was performed by censored log-rank test and presented by Kaplan–Meier curves. The rhythm monitoring methods were used among 2658 patients: ECG ( N = 578), Holter ECG ( N = 1874), TTMON ( N = 101), and ICM ( N = 105). A total of 767 of 2658 patients (28.9%) had AF recurrences during follow-up. Censored log-rank test discovered a lower probability of freedom from relapses, which was detected with ICM compared to TTMON, ECG, and Holter ECG ( P < 0.001). The rate of freedom from AF recurrences was 50.5% among patients using the ICM while it was 65.4%, 70.6%, and 72.8% using the TTMON, ECG, and Holter ECG, respectively. Conclusion: Comparing all main electrocardiographic monitoring methods in a large patient sample, our results suggest that post-ablation recurrences of AF are significantly underreported by TTMON, ECG, and Holter ECG. The ICM estimates AF ablation recurrences most reliably and should be a preferred mode of monitoring for trials evaluating novel AF ablation techniques. … (more)
- Is Part Of:
- Europace. Volume 21:Issue 12(2019)
- Journal:
- Europace
- Issue:
- Volume 21:Issue 12(2019)
- Issue Display:
- Volume 21, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 21
- Issue:
- 12
- Issue Sort Value:
- 2019-0021-0012-0000
- Page Start:
- 1802
- Page End:
- 1808
- Publication Date:
- 2019-08-13
- Subjects:
- Atrial fibrillation -- Ablation -- Recurrence -- Rhythm monitoring -- EHRA registry
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euz216 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12437.xml