Transcranial Doppler Waveforms During Intra-aortic Balloon Pump Counterpulsation for Vasospasm Detection After Subarachnoid Hemorrhage. Issue 3 (21st July 2017)
- Record Type:
- Journal Article
- Title:
- Transcranial Doppler Waveforms During Intra-aortic Balloon Pump Counterpulsation for Vasospasm Detection After Subarachnoid Hemorrhage. Issue 3 (21st July 2017)
- Main Title:
- Transcranial Doppler Waveforms During Intra-aortic Balloon Pump Counterpulsation for Vasospasm Detection After Subarachnoid Hemorrhage
- Authors:
- Morris, Nicholas A
Manning, Nathan
Marshall, Randolph S
Connolly, E Sander
Claassen, Jan
Agarwal, Sachin
Roh, David J
Schmidt, J Michael
Park, Soojin - Abstract:
- Abstract: BACKGROUND: Transcranial Doppler ultrasound is a standard screening tool for vasospasm after subarachnoid hemorrhage. Prevention of vasospasm-induced delayed cerebral ischemia after subarachnoid hemorrhage depends on optimization of cerebral perfusion pressure, which can be challenged by neurogenic stress cardiomyopathy. Intra-aortic balloon pumps have been utilized to augment cerebral perfusion, but they change the transcranial Doppler waveform, altering its interpretability for vasospasm screening. OBJECTIVE: To assess the features of the transcranial Doppler waveform that correlate with vasospasm. METHODS: We retrospectively reviewed cases of subarachnoid hemorrhage that underwent same-day transcranial Doppler ultrasound and angiography. Transcranial Doppler waveforms were assessed for mean velocity, peak systolic velocity, balloon pump-augmented diastolic velocity, and a novel feature, "delta velocity" (balloon pump-augmented velocity − systolic velocity). Relationship of flow velocity features to vasospasm was estimated by generalized estimating equation models using a Gaussian distribution and an exchangeable correlation structure. RESULTS: There were 31 transcranial Doppler and angiography pairings (12 CT angiography/19 digital subtraction angiography) from 4 patients. Fourteen pairings had proximal vasospasm by angiography. Delta velocity was associated with proximal vasospasm (coefficient –6.8 [95% CI –9.8 to –3.8], P < .001). There was no significantAbstract: BACKGROUND: Transcranial Doppler ultrasound is a standard screening tool for vasospasm after subarachnoid hemorrhage. Prevention of vasospasm-induced delayed cerebral ischemia after subarachnoid hemorrhage depends on optimization of cerebral perfusion pressure, which can be challenged by neurogenic stress cardiomyopathy. Intra-aortic balloon pumps have been utilized to augment cerebral perfusion, but they change the transcranial Doppler waveform, altering its interpretability for vasospasm screening. OBJECTIVE: To assess the features of the transcranial Doppler waveform that correlate with vasospasm. METHODS: We retrospectively reviewed cases of subarachnoid hemorrhage that underwent same-day transcranial Doppler ultrasound and angiography. Transcranial Doppler waveforms were assessed for mean velocity, peak systolic velocity, balloon pump-augmented diastolic velocity, and a novel feature, "delta velocity" (balloon pump-augmented velocity − systolic velocity). Relationship of flow velocity features to vasospasm was estimated by generalized estimating equation models using a Gaussian distribution and an exchangeable correlation structure. RESULTS: There were 31 transcranial Doppler and angiography pairings (12 CT angiography/19 digital subtraction angiography) from 4 patients. Fourteen pairings had proximal vasospasm by angiography. Delta velocity was associated with proximal vasospasm (coefficient –6.8 [95% CI –9.8 to –3.8], P < .001). There was no significant correlation with proximal vasospasm for mean velocity (coefficient –13.0 [95% CI –29.3 to 3.4], P = .12), systolic velocity (coefficient –8.7 [95% CI –24.8 to 7.3], P = .29), or balloon pump-augmented velocity (coefficient –15.3 [95% CI –31.3 to 0.71], P = .06). CONCLUSION: Delta velocity, a novel transcranial Doppler flow velocity feature, may reflect vasospasm in patients with subarachnoid hemorrhage and intra-aortic balloon pumps. … (more)
- Is Part Of:
- Neurosurgery. Volume 83:Issue 3(2018)
- Journal:
- Neurosurgery
- Issue:
- Volume 83:Issue 3(2018)
- Issue Display:
- Volume 83, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 83
- Issue:
- 3
- Issue Sort Value:
- 2018-0083-0003-0000
- Page Start:
- 416
- Page End:
- 421
- Publication Date:
- 2017-07-21
- Subjects:
- Cerebral vasospasm -- Intra-aortic balloon counterpulsation -- Neurogenic stress cardiomyopathy -- Subarachnoid hemorrhage -- Takotsubo cardiomyopathy -- Transcranial Doppler
Nervous system -- Surgery -- Periodicals
617.48005 - Journal URLs:
- https://academic.oup.com/neurosurgery ↗
http://www.neurosurgery-online.com ↗
https://journals.lww.com/neurosurgery/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1093/neuros/nyx405 ↗
- Languages:
- English
- ISSNs:
- 0148-396X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.582000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12411.xml