Evaluating the accuracy of multicomponent T2 parameters for luminal water imaging of the prostate with acceleration using inner‐volume 3D GRASE. Issue 1 (29th July 2018)
- Record Type:
- Journal Article
- Title:
- Evaluating the accuracy of multicomponent T2 parameters for luminal water imaging of the prostate with acceleration using inner‐volume 3D GRASE. Issue 1 (29th July 2018)
- Main Title:
- Evaluating the accuracy of multicomponent T2 parameters for luminal water imaging of the prostate with acceleration using inner‐volume 3D GRASE
- Authors:
- Chan, Rachel W.
Lau, Angus Z.
Detzler, Garry
Thayalasuthan, Vivekanandan
Nam, Robert K.
Haider, Masoom A. - Abstract:
- Abstract : Purpose: Prostate cancer can be detected using a multicomponent T2 mapping technique termed luminal water imaging . The purpose of this study is twofold: 1) To accelerate the luminal water imaging acquisition by using inner volume selection as part of a gradient and spin echo sequence, and 2) to evaluate the accuracy of luminal water fractions and multicomponent T2 relaxation times. Methods: The accuracy of parameter estimates was assessed using Monte Carlo simulations, in phantom experiments and in the prostate (in 5 healthy subjects). Two fitting methods, nonnegative least squares and biexponential fitting with stimulated echo correction, were compared. Results: Results demonstrate that inner volume selection in a gradient and spin echo sequence is effective for accelerating prostate luminal water imaging by at least threefold. Evaluation of the accuracy shows that the estimated luminal water fractions are relatively accurate, but the short‐ and long‐T2 relaxation times should be interpreted with caution in noisy scenarios (SNR < 100) and when the corresponding fractions are small ( < 0.5). The mean luminal water fractions obtained at SNR above 100 are 0.27 ± 0.07 for the peripheral zone for both fitting methods, 0.16 ± 0.04 for the transition zone with nonnegative least squares, and 0.16 ± 0.03 for the transition zone with biexponential fitting including stimulated echo correction. Conclusion: The shortened scan duration allows the luminal water imagingAbstract : Purpose: Prostate cancer can be detected using a multicomponent T2 mapping technique termed luminal water imaging . The purpose of this study is twofold: 1) To accelerate the luminal water imaging acquisition by using inner volume selection as part of a gradient and spin echo sequence, and 2) to evaluate the accuracy of luminal water fractions and multicomponent T2 relaxation times. Methods: The accuracy of parameter estimates was assessed using Monte Carlo simulations, in phantom experiments and in the prostate (in 5 healthy subjects). Two fitting methods, nonnegative least squares and biexponential fitting with stimulated echo correction, were compared. Results: Results demonstrate that inner volume selection in a gradient and spin echo sequence is effective for accelerating prostate luminal water imaging by at least threefold. Evaluation of the accuracy shows that the estimated luminal water fractions are relatively accurate, but the short‐ and long‐T2 relaxation times should be interpreted with caution in noisy scenarios (SNR < 100) and when the corresponding fractions are small ( < 0.5). The mean luminal water fractions obtained at SNR above 100 are 0.27 ± 0.07 for the peripheral zone for both fitting methods, 0.16 ± 0.04 for the transition zone with nonnegative least squares, and 0.16 ± 0.03 for the transition zone with biexponential fitting including stimulated echo correction. Conclusion: The shortened scan duration allows the luminal water imaging sequence to be easily integrated into a standard multiparametric prostate MRI protocol. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 81:Issue 1(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 81:Issue 1(2019)
- Issue Display:
- Volume 81, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 81
- Issue:
- 1
- Issue Sort Value:
- 2019-0081-0001-0000
- Page Start:
- 466
- Page End:
- 476
- Publication Date:
- 2018-07-29
- Subjects:
- multicomponent T2 -- prostate MRI -- quantitative imaging -- quantitative T2 -- T2 mapping
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27372 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12417.xml