Accelerating chemical exchange saturation transfer MRI with parallel blind compressed sensing. Issue 1 (26th August 2018)
- Record Type:
- Journal Article
- Title:
- Accelerating chemical exchange saturation transfer MRI with parallel blind compressed sensing. Issue 1 (26th August 2018)
- Main Title:
- Accelerating chemical exchange saturation transfer MRI with parallel blind compressed sensing
- Authors:
- She, Huajun
Greer, Joshua S.
Zhang, Shu
Li, Bian
Keupp, Jochen
Madhuranthakam, Ananth J.
Dimitrov, Ivan E.
Lenkinski, Robert E.
Vinogradov, Elena - Abstract:
- Abstract : Purpose: Chemical exchange saturation transfer is a novel and promising MRI contrast method, but it can be time‐consuming. Common parallel imaging methods, like SENSE, can lead to reduced quality of CEST. Here, parallel blind compressed sensing (PBCS), combining blind compressed sensing (BCS) and parallel imaging, is evaluated for the acceleration of CEST in brain and breast. Methods: The CEST data were collected in phantoms, brain ( N = 3), and breast ( N = 2). Retrospective Cartesian undersampling was implemented and the reconstruction results of PBCS‐CEST were compared with BCS‐CEST and k‐t sparse‐SENSE CEST. The normalized RMSE and the high‐frequency error norm were used for quantitative comparison. Results: In phantom and in vivo brain experiments, the acceleration factor of R = 10 (24 k‐space lines) was achieved and in breast R = 5 (30 k‐space lines), without compromising the quality of the PBCS‐reconstructed magnetization transfer rate asymmetry maps and Z‐spectra. Parallel BCS provides better reconstruction quality when compared with BCS, k‐t sparse‐SENSE, and SENSE methods using the same number of samples. Parallel BCS overperforms BCS, indicating that the inclusion of coil sensitivity improves the reconstruction of the CEST data. Conclusion: The PBCS method accelerates CEST without compromising its quality. Compressed sensing in combination with parallel imaging can provide a valuable alternative to parallel imaging alone for accelerating CESTAbstract : Purpose: Chemical exchange saturation transfer is a novel and promising MRI contrast method, but it can be time‐consuming. Common parallel imaging methods, like SENSE, can lead to reduced quality of CEST. Here, parallel blind compressed sensing (PBCS), combining blind compressed sensing (BCS) and parallel imaging, is evaluated for the acceleration of CEST in brain and breast. Methods: The CEST data were collected in phantoms, brain ( N = 3), and breast ( N = 2). Retrospective Cartesian undersampling was implemented and the reconstruction results of PBCS‐CEST were compared with BCS‐CEST and k‐t sparse‐SENSE CEST. The normalized RMSE and the high‐frequency error norm were used for quantitative comparison. Results: In phantom and in vivo brain experiments, the acceleration factor of R = 10 (24 k‐space lines) was achieved and in breast R = 5 (30 k‐space lines), without compromising the quality of the PBCS‐reconstructed magnetization transfer rate asymmetry maps and Z‐spectra. Parallel BCS provides better reconstruction quality when compared with BCS, k‐t sparse‐SENSE, and SENSE methods using the same number of samples. Parallel BCS overperforms BCS, indicating that the inclusion of coil sensitivity improves the reconstruction of the CEST data. Conclusion: The PBCS method accelerates CEST without compromising its quality. Compressed sensing in combination with parallel imaging can provide a valuable alternative to parallel imaging alone for accelerating CEST experiments. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 81:Issue 1(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 81:Issue 1(2019)
- Issue Display:
- Volume 81, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 81
- Issue:
- 1
- Issue Sort Value:
- 2019-0081-0001-0000
- Page Start:
- 504
- Page End:
- 513
- Publication Date:
- 2018-08-26
- Subjects:
- blind compressed sensing -- CEST -- CEST acceleration -- parallel blind compressed sensing -- parallel imaging
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27400 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12417.xml