BIM-based framework to analyze the effect of natural ventilation on thermal comfort and energy performance in buildings. (February 2019)
- Record Type:
- Journal Article
- Title:
- BIM-based framework to analyze the effect of natural ventilation on thermal comfort and energy performance in buildings. (February 2019)
- Main Title:
- BIM-based framework to analyze the effect of natural ventilation on thermal comfort and energy performance in buildings
- Authors:
- Gan, Vincent J.L.
Deng, M.
Tan, Y.
Chen, W.
Cheng, Jack C.P. - Abstract:
- Abstract: Buildings use significant amount of energy worldwide, with mechanical air-conditioning systems accounting for a large proportion of the total energy consumed. Utilizing natural ventilation can achieve a comfortable indoor thermal environment while reducing the use of air-conditioning and building energy consumption. However, previous studies mainly focused on either thermal comfort or energy conservation by utilizing natural ventilation. The correlation between thermal comfort and energy performance due to the effect of natural ventilation is important, but has not been studied thoroughly in literature. Moreover, natural ventilation in buildings is greatly affected by building geometry, material property, outdoor environmental condition and occupancy, which were not fully incorporated in the previous studies. This paper presents a framework based on building information modeling (BIM) to study the effect of natural ventilation on the correlation between thermal comfort and energy performance. BIM provides 3D building models with detailed geometric and material information as well as the building location and type that help determine the outdoor environmental condition and occupancy, thereby improving the accuracy of natural ventilation simulation. A case study was conducted using the proposed framework, aimed at investigating the natural ventilation in a residential flat in Hong Kong at different seasons. The results show that utilizing natural ventilation cannotAbstract: Buildings use significant amount of energy worldwide, with mechanical air-conditioning systems accounting for a large proportion of the total energy consumed. Utilizing natural ventilation can achieve a comfortable indoor thermal environment while reducing the use of air-conditioning and building energy consumption. However, previous studies mainly focused on either thermal comfort or energy conservation by utilizing natural ventilation. The correlation between thermal comfort and energy performance due to the effect of natural ventilation is important, but has not been studied thoroughly in literature. Moreover, natural ventilation in buildings is greatly affected by building geometry, material property, outdoor environmental condition and occupancy, which were not fully incorporated in the previous studies. This paper presents a framework based on building information modeling (BIM) to study the effect of natural ventilation on the correlation between thermal comfort and energy performance. BIM provides 3D building models with detailed geometric and material information as well as the building location and type that help determine the outdoor environmental condition and occupancy, thereby improving the accuracy of natural ventilation simulation. A case study was conducted using the proposed framework, aimed at investigating the natural ventilation in a residential flat in Hong Kong at different seasons. The results show that utilizing natural ventilation cannot always achieve thermal comfort. Natural ventilation brings cool air in late spring (April) during which the indoor temperature can be controlled at a comfortable level and the energy use for mechanical ventilation can be saved. The proposed framework helps evaluate the natural ventilation in buildings for maintaining indoor thermal comfort at minimal energy use, thereby creating a more sustainable built environment. … (more)
- Is Part Of:
- Energy procedia. Volume 158(2019)
- Journal:
- Energy procedia
- Issue:
- Volume 158(2019)
- Issue Display:
- Volume 158, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 158
- Issue:
- 2019
- Issue Sort Value:
- 2019-0158-2019-0000
- Page Start:
- 3319
- Page End:
- 3324
- Publication Date:
- 2019-02
- Subjects:
- Air ventilation assessment -- building information modeling -- energy efficiency -- thermal comfort -- integrated building design
Power resources -- Congresses
Power resources -- Periodicals
Power resources
Conference proceedings
Periodicals
333.7905 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18766102 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.egypro.2019.01.971 ↗
- Languages:
- English
- ISSNs:
- 1876-6102
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.729700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12398.xml