Realistic 4D MRI abdominal phantom for the evaluation and comparison of acquisition and reconstruction techniques. Issue 3 (5th November 2018)
- Record Type:
- Journal Article
- Title:
- Realistic 4D MRI abdominal phantom for the evaluation and comparison of acquisition and reconstruction techniques. Issue 3 (5th November 2018)
- Main Title:
- Realistic 4D MRI abdominal phantom for the evaluation and comparison of acquisition and reconstruction techniques
- Authors:
- Lo, Wei‐Ching
Chen, Yong
Jiang, Yun
Hamilton, Jesse
Grimm, Robert
Griswold, Mark
Gulani, Vikas
Seiberlich, Nicole - Abstract:
- Abstract : Purpose: This work presents a 4D numerical abdominal phantom, which includes T1 and T2 relaxation times, proton density fat fraction, perfusion, and diffusion, as well as respiratory motion for the evaluation and comparison of acquisition and reconstruction techniques. Methods: The 3D anatomical mesh models were non‐rigidly scaled and shifted by respiratory motion derived from an in vivo scan. A time series of voxelized 3D abdominal phantom images were obtained with contrast determined by the tissue properties and pulse sequence parameters. Two example simulations: (1) 3D T1 mapping under breath‐hold and free‐breathing acquisition conditions and (2) two different reconstruction techniques for accelerated 3D dynamic contrast‐enhanced MRI, are presented. The source codes can be found at https://github.com/SeiberlichLab/Abdominal_MR_Phantom . Results: The proposed 4D abdominal phantom can successfully simulate images and MRI data with nonrigid respiratory motion and specific contrast settings and data sampling schemes. In example 1, the use of a numerical 4D abdominal phantom was demonstrated to aid in the comparison between different approaches for volumetric T1 mapping. In example 2, the average arterial fraction over the healthy hepatic parenchyma as calculated with spiral generalized autocalibrating partial parallel acquisition was closer to that from the fully sampled data than the arterial fraction from conjugate gradient sensitivity encoding, although both areAbstract : Purpose: This work presents a 4D numerical abdominal phantom, which includes T1 and T2 relaxation times, proton density fat fraction, perfusion, and diffusion, as well as respiratory motion for the evaluation and comparison of acquisition and reconstruction techniques. Methods: The 3D anatomical mesh models were non‐rigidly scaled and shifted by respiratory motion derived from an in vivo scan. A time series of voxelized 3D abdominal phantom images were obtained with contrast determined by the tissue properties and pulse sequence parameters. Two example simulations: (1) 3D T1 mapping under breath‐hold and free‐breathing acquisition conditions and (2) two different reconstruction techniques for accelerated 3D dynamic contrast‐enhanced MRI, are presented. The source codes can be found at https://github.com/SeiberlichLab/Abdominal_MR_Phantom . Results: The proposed 4D abdominal phantom can successfully simulate images and MRI data with nonrigid respiratory motion and specific contrast settings and data sampling schemes. In example 1, the use of a numerical 4D abdominal phantom was demonstrated to aid in the comparison between different approaches for volumetric T1 mapping. In example 2, the average arterial fraction over the healthy hepatic parenchyma as calculated with spiral generalized autocalibrating partial parallel acquisition was closer to that from the fully sampled data than the arterial fraction from conjugate gradient sensitivity encoding, although both are elevated compared to the gold‐standard reference. Conclusion: This realistic abdominal MR phantom can be used to simulate different pulse sequences and data sampling schemes for the comparison of acquisition and reconstruction methods under controlled conditions that are impossible or prohibitively difficult to perform in vivo. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 81:Issue 3(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 81:Issue 3(2019)
- Issue Display:
- Volume 81, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 81
- Issue:
- 3
- Issue Sort Value:
- 2019-0081-0003-0000
- Page Start:
- 1863
- Page End:
- 1875
- Publication Date:
- 2018-11-05
- Subjects:
- abdomen -- digital phantom -- free breathing -- MRI
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27545 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12391.xml