PEC‐GRAPPA reconstruction of simultaneous multislice EPI with slice‐dependent 2D Nyquist ghost correction. Issue 3 (12th October 2018)
- Record Type:
- Journal Article
- Title:
- PEC‐GRAPPA reconstruction of simultaneous multislice EPI with slice‐dependent 2D Nyquist ghost correction. Issue 3 (12th October 2018)
- Main Title:
- PEC‐GRAPPA reconstruction of simultaneous multislice EPI with slice‐dependent 2D Nyquist ghost correction
- Authors:
- Liu, Yilong
Lyu, Mengye
Barth, Markus
Yi, Zheyuan
Leong, Alex T. L.
Chen, Fei
Feng, Yanqiu
Wu, Ed X. - Abstract:
- Abstract : Purpose: To provide simultaneous multislice (SMS) EPI reconstruction with k‐space implementation and robust Nyquist ghost correction. Methods: 2D phase error correction SENSE (PEC‐SENSE) was recently developed for Nyquist ghost correction in SMS EPI reconstruction for which virtual coil simultaneous autocalibration and k‐space estimation (VC‐SAKE) was used to remove slice‐dependent Nyquist ghosts and intershot 2D phase variations in multi‐shot EPI reference scan. However, masking coil sensitivity maps to exclude background region in PEC‐SENSE and manually selecting slice‐wise target ranks in VC‐SAKE are cumbersome procedures in practice. To avoid masking, the concept of PEC‐SENSE is extended to k‐space implementation and termed as PEC‐GRAPPA . Furthermore, a singular value shrinkage scheme is incorporated in VC‐SAKE to circumvent the empirical slice‐wise target rank selection. PEC‐GRAPPA was evaluated and compared to PEC‐SENSE with/without masking and 1D linear phase correction GRAPPA. Results: PEC‐GRAPPA robustly reconstructed SMS EPI images from 7T phantom and human brain data, effectively removing the phase error‐induced artifacts. The resulting residual artifact level and temporal SNR were comparable to those by PEC‐SENSE with careful tuning. PEC‐GRAPPA outperformed PEC‐SENSE without masking and 1D linear phase correction GRAPPA. Conclusion: Our proposed PEC‐GRAPPA approach effectively removes the artifacts caused by Nyquist ghosts in SMS EPI withoutAbstract : Purpose: To provide simultaneous multislice (SMS) EPI reconstruction with k‐space implementation and robust Nyquist ghost correction. Methods: 2D phase error correction SENSE (PEC‐SENSE) was recently developed for Nyquist ghost correction in SMS EPI reconstruction for which virtual coil simultaneous autocalibration and k‐space estimation (VC‐SAKE) was used to remove slice‐dependent Nyquist ghosts and intershot 2D phase variations in multi‐shot EPI reference scan. However, masking coil sensitivity maps to exclude background region in PEC‐SENSE and manually selecting slice‐wise target ranks in VC‐SAKE are cumbersome procedures in practice. To avoid masking, the concept of PEC‐SENSE is extended to k‐space implementation and termed as PEC‐GRAPPA . Furthermore, a singular value shrinkage scheme is incorporated in VC‐SAKE to circumvent the empirical slice‐wise target rank selection. PEC‐GRAPPA was evaluated and compared to PEC‐SENSE with/without masking and 1D linear phase correction GRAPPA. Results: PEC‐GRAPPA robustly reconstructed SMS EPI images from 7T phantom and human brain data, effectively removing the phase error‐induced artifacts. The resulting residual artifact level and temporal SNR were comparable to those by PEC‐SENSE with careful tuning. PEC‐GRAPPA outperformed PEC‐SENSE without masking and 1D linear phase correction GRAPPA. Conclusion: Our proposed PEC‐GRAPPA approach effectively removes the artifacts caused by Nyquist ghosts in SMS EPI without cumbersome tuning. This approach provides a robust and practical implementation of SMS EPI reconstruction in k‐space with slice‐dependent 2D Nyquist ghost correction. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 81:Issue 3(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 81:Issue 3(2019)
- Issue Display:
- Volume 81, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 81
- Issue:
- 3
- Issue Sort Value:
- 2019-0081-0003-0000
- Page Start:
- 1924
- Page End:
- 1934
- Publication Date:
- 2018-10-12
- Subjects:
- EPI -- GRAPPA -- multiband -- Nyquist ghost -- parallel imaging -- SMS
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27546 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12391.xml