Model‐based reconstruction framework for correction of signal pile‐up and geometric distortions in prostate diffusion MRI. Issue 3 (4th November 2018)
- Record Type:
- Journal Article
- Title:
- Model‐based reconstruction framework for correction of signal pile‐up and geometric distortions in prostate diffusion MRI. Issue 3 (4th November 2018)
- Main Title:
- Model‐based reconstruction framework for correction of signal pile‐up and geometric distortions in prostate diffusion MRI
- Authors:
- Usman, Muhammad
Kakkar, Lebina
Kirkham, Alex
Arridge, Simon
Atkinson, David - Abstract:
- Abstract : Purpose: Prostate diffusion‐weighted MRI scans can suffer from geometric distortions, signal pileup, and signal dropout attributed to differences in tissue susceptibility values at the interface between the prostate and rectal air. The aim of this work is to present and validate a novel model based reconstruction method that can correct for these distortions. Methods: In regions of severe signal pileup, standard techniques for distortion correction have difficulty recovering the underlying true signal. Furthermore, because of drifts and inaccuracies in the determination of center frequency, echo planar imaging (EPI) scans can be shifted in the phase‐encoding direction. In this work, using a B0 field map and a set of EPI data acquired with blip‐up and blip‐down phase encoding gradients, we model the distortion correction problem linking the distortion‐free image to the acquired raw corrupted k‐space data and solve it in a manner analogous to the sensitivity encoding method. Both a quantitative and qualitative assessment of the proposed method is performed in vivo in 10 patients. Results: Without distortion correction, mean Dice similarity scores between a reference T2W and the uncorrected EPI images were 0.64 and 0.60 for b‐values of 0 and 500 s/mm 2, respectively. Compared to the Topup (distortion correction method commonly used for neuro imaging), the proposed method achieved Dice scores (0.87 and 0.85 versus 0.82 and 0.80) and better qualitative results inAbstract : Purpose: Prostate diffusion‐weighted MRI scans can suffer from geometric distortions, signal pileup, and signal dropout attributed to differences in tissue susceptibility values at the interface between the prostate and rectal air. The aim of this work is to present and validate a novel model based reconstruction method that can correct for these distortions. Methods: In regions of severe signal pileup, standard techniques for distortion correction have difficulty recovering the underlying true signal. Furthermore, because of drifts and inaccuracies in the determination of center frequency, echo planar imaging (EPI) scans can be shifted in the phase‐encoding direction. In this work, using a B0 field map and a set of EPI data acquired with blip‐up and blip‐down phase encoding gradients, we model the distortion correction problem linking the distortion‐free image to the acquired raw corrupted k‐space data and solve it in a manner analogous to the sensitivity encoding method. Both a quantitative and qualitative assessment of the proposed method is performed in vivo in 10 patients. Results: Without distortion correction, mean Dice similarity scores between a reference T2W and the uncorrected EPI images were 0.64 and 0.60 for b‐values of 0 and 500 s/mm 2, respectively. Compared to the Topup (distortion correction method commonly used for neuro imaging), the proposed method achieved Dice scores (0.87 and 0.85 versus 0.82 and 0.80) and better qualitative results in patients where signal pileup was present because of high rectal gas residue. Conclusion: Model‐based reconstruction can be used for distortion correction in prostate diffusion MRI. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 81:Issue 3(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 81:Issue 3(2019)
- Issue Display:
- Volume 81, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 81
- Issue:
- 3
- Issue Sort Value:
- 2019-0081-0003-0000
- Page Start:
- 1979
- Page End:
- 1992
- Publication Date:
- 2018-11-04
- Subjects:
- geometric distortion -- diffusion -- prostate MRI -- signal pile‐up
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27547 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12391.xml