Effect of Nearly Isometric ACL Reconstruction on Graft-Tunnel Motion: A Quantitative Clinical Study. Issue 12 (24th December 2019)
- Record Type:
- Journal Article
- Title:
- Effect of Nearly Isometric ACL Reconstruction on Graft-Tunnel Motion: A Quantitative Clinical Study. Issue 12 (24th December 2019)
- Main Title:
- Effect of Nearly Isometric ACL Reconstruction on Graft-Tunnel Motion: A Quantitative Clinical Study
- Authors:
- Wan, Fang
Chen, Tianwu
Ge, Yunshen
Zhang, Peng
Chen, Shiyi - Abstract:
- Background: In anterior cruciate ligament (ACL) reconstruction, minimizing the graft-tunnel motion (GTM) will promote graft-to-bone healing and avoid graft loosening or tearing as well as potential bone tunnel enlargement. A nearly isometric state of the graft can be achieved by placing the tunnel properly to theoretically gain better graft-to-bone healing. However, little clinical evidence is available to quantify the relation between GTM and tunnel position. Purpose: To find the proper zones for the femoral and tibial tunnel apertures that minimize the GTM, referred to as the "nearly isometric zone, " through use of intraoperative GTM measurement and 3-dimensional computed tomography (3D-CT). Study Design: Cross-sectional study; Level of evidence, 3. Methods: A total of 100 patients were enrolled in this study. Nearly isometric ACL reconstruction was performed, and an intra-articular GTM measuring device was designed to measure and record the amplitude of GTM while the knee was flexed from 0° to 120°. Postoperatively, the patients underwent multislice CT, and the images were used to create 3D-CT models. After tibial aperture examination, 5 patients were excluded due to the divergence of tibial aperture, and therefore 95 patients remained in the study. Patients were divided into 2 groups according to whether the lateral intercondylar ridge was absent or present. The Bernard-Hertel grid coordinates ( h, t ) of the femoral tunnel were then quantified. Results: The maximal GTMBackground: In anterior cruciate ligament (ACL) reconstruction, minimizing the graft-tunnel motion (GTM) will promote graft-to-bone healing and avoid graft loosening or tearing as well as potential bone tunnel enlargement. A nearly isometric state of the graft can be achieved by placing the tunnel properly to theoretically gain better graft-to-bone healing. However, little clinical evidence is available to quantify the relation between GTM and tunnel position. Purpose: To find the proper zones for the femoral and tibial tunnel apertures that minimize the GTM, referred to as the "nearly isometric zone, " through use of intraoperative GTM measurement and 3-dimensional computed tomography (3D-CT). Study Design: Cross-sectional study; Level of evidence, 3. Methods: A total of 100 patients were enrolled in this study. Nearly isometric ACL reconstruction was performed, and an intra-articular GTM measuring device was designed to measure and record the amplitude of GTM while the knee was flexed from 0° to 120°. Postoperatively, the patients underwent multislice CT, and the images were used to create 3D-CT models. After tibial aperture examination, 5 patients were excluded due to the divergence of tibial aperture, and therefore 95 patients remained in the study. Patients were divided into 2 groups according to whether the lateral intercondylar ridge was absent or present. The Bernard-Hertel grid coordinates ( h, t ) of the femoral tunnel were then quantified. Results: The maximal GTM (mGTM) was a mean ± SD of 1.06 ± 0.66 mm (range, 0.0-3.0 mm). The mGTM in patients with a lateral intercondylar ridge was significantly lower than that in patients without a lateral intercondylar ridge (0.81 ± 0.39 vs 1.59 ± 0.73 mm, respectively; P < .0001). The average h and t were 0.227 ± 0.079 and 0.429 ± 0.770, respectively. Notably, in 1 patient, the mGTM was 0 mm whereas the coordinates ( h, t ) of the femoral tunnel were 0.250 and 0.255. The overall GTM slowly increased before 90° but increased significantly after the knee was bent 105° ( P = .010). Correlation analysis showed that the t coordiinate had significant correlation with mGTM ( R = 0.581; P < .001). A gradient pattern was created to show the nearly isometric blue zone (mGTM <0.5 mm), which was found to overlap with the IDEAL (isometric, direct insertion, eccentric, anatomic, low tension-flexion pattern) position. Conclusion: A method of measuring intraoperative GTM and quantifying femoral tunnel position on postoperative 3D-CT was successfully developed. The presence of a lateral condylar ridge can significantly reduce mGTM. A nearly isometric zone was described that was consistent with the IDEAL concept. … (more)
- Is Part Of:
- Orthopaedic journal of sports medicine. Volume 7:Issue 12(2019)
- Journal:
- Orthopaedic journal of sports medicine
- Issue:
- Volume 7:Issue 12(2019)
- Issue Display:
- Volume 7, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 7
- Issue:
- 12
- Issue Sort Value:
- 2019-0007-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-12-24
- Subjects:
- anterior cruciate ligament reconstruction -- near isometry -- nearly isometric zone -- graft-tunnel motion
Sports medicine -- Periodicals
Orthopedics -- Periodicals
Arthroscopy -- Periodicals
Arthroplasty -- Periodicals
Knee -- Surgery -- Periodicals
616.7 - Journal URLs:
- http://www.sagepublications.com/ ↗
- DOI:
- 10.1177/2325967119890382 ↗
- Languages:
- English
- ISSNs:
- 2325-9671
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12379.xml