AvalonElite Double Lumen Cannula for Total Cavopulmonary Assist in Failing Fontan Sheep Model with Valved Extracardiac Conduit. Issue 4 (May 2019)
- Record Type:
- Journal Article
- Title:
- AvalonElite Double Lumen Cannula for Total Cavopulmonary Assist in Failing Fontan Sheep Model with Valved Extracardiac Conduit. Issue 4 (May 2019)
- Main Title:
- AvalonElite Double Lumen Cannula for Total Cavopulmonary Assist in Failing Fontan Sheep Model with Valved Extracardiac Conduit
- Authors:
- Zhou, Cheng
Wang, Dongfang
Condemi, Francesca
Zhao, Guangfeng
Topaz, Stephen
Ballard-Croft, Cherry
Zwischenberger, Joseph B. - Abstract:
- Abstract : The AvalonElite double lumen cannula (DLC) provides total cavopulmonary assist (CPA) in failing Fontan sheep, but recirculation limits reliability. To improve CPA performance, a two-valve extracardiac conduit (ECC) was used to bracket infusion blood toward pulmonary artery (PA). A total cavopulmonary connection with failing Fontan circulation adult sheep model was created with valved ECC (n = 6). The valved ECC was connected to superior/inferior venae cavae (SVC/IVC) and right PA. The AvalonElite DLC was inserted from right jugular vein with infusion opening between the ECC valves. The DLC drainage lumen withdrew blood from SVC/IVC, and the infusion lumen returned blood to ECC. A failing Fontan sheep model with valved ECC was successfully created. Central venous pressure increased from 9 ± 1 to 17 ± 1 mm Hg, systolic arterial pressure decreased from 103 ± 9 to 51 ± 13 mm Hg, and cardiac output decreased from 3.6 ± 0.3 to 1.4 ± 0.2 L/min. Serum lactate significantly increased, indicating poor tissue perfusion. At 4 L/min pumping flow, the AvalonElite DLC returned hemodynamics/lactate to baseline levels throughout 6 hour CPA. Necropsy revealed intact/well-functioning ECC valves and well-positioned DLC with no visible thrombosis. The AvalonElite DLC provides reliable CPA performance in failing Fontan sheep with valved ECC.
- Is Part Of:
- ASAIO journal. Volume 65:Issue 4(2019)
- Journal:
- ASAIO journal
- Issue:
- Volume 65:Issue 4(2019)
- Issue Display:
- Volume 65, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 65
- Issue:
- 4
- Issue Sort Value:
- 2019-0065-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-05
- Subjects:
- cavopulmonary assist -- AvalonElite -- Fontan -- total cavopulmonary connection -- sheep
Artificial organs -- Periodicals
617 - Journal URLs:
- http://journals.lww.com/asaiojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAT.0000000000000817 ↗
- Languages:
- English
- ISSNs:
- 1058-2916
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1738.840500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12383.xml