Dual-Energy Computed Tomography in Loosening of Revision Hip Prosthesis: A Comparison Between MARS and non-MARS Images. Issue 3 (May 2019)
- Record Type:
- Journal Article
- Title:
- Dual-Energy Computed Tomography in Loosening of Revision Hip Prosthesis: A Comparison Between MARS and non-MARS Images. Issue 3 (May 2019)
- Main Title:
- Dual-Energy Computed Tomography in Loosening of Revision Hip Prosthesis
- Authors:
- Guziński, Maciej
Kubicki, Konrad
Waszczuk, Łukasz
Morawska-Kochman, Monika
Kochman, Andrzej
Sąsiadek, Marek - Abstract:
- Abstract : Purpose: The aim of the study was to assess potential endoprosthesis loosening in patients after revision total hip arthroplasty, based on monochromatic dual-energy computed tomography (DECT) images obtained with and without metal artifact reduction software (MARS) and comparison with the clinical examination and hip function. Materials and Methods: Twenty-five consecutive patients underwent DECT examinations. Two monochromatic data sets were generated: with MARS (75-keV MARS) and without MARS (140-keV non-MARS) and evaluated for signs of loosening, using a dedicated radiological score. The Harris Hip Score (HHS) was used to evaluate patients' hip function. Results: The mean radiological score for loosening in the non-MARS group was 16.2, in the MARS group 17.0 and was significantly higher ( P < 0.001). Radiological loosening evaluation in non-MARS images correlated with the HHS score (ρ = 0.43, P = 0.03), whereas there was no correlation between MARS images and HHS (ρ = 0.15, P = 0.47). New MARS-related artifacts, which hinder implant-bone interface evaluation, were found in 75-keV MARS images ("pseudo-loosening" in 33 of 34 prostheses, "ground-glass blurring" in 20 of 32). Conclusions: High-energy monochromatic DECT images are superior to low-energy DECT MARS images in assessment of the potential loosening and correlate better with the clinical examination outcomes. For revision total hip arthroplasty evaluation, 2 data sets should be assessed inseparablyAbstract : Purpose: The aim of the study was to assess potential endoprosthesis loosening in patients after revision total hip arthroplasty, based on monochromatic dual-energy computed tomography (DECT) images obtained with and without metal artifact reduction software (MARS) and comparison with the clinical examination and hip function. Materials and Methods: Twenty-five consecutive patients underwent DECT examinations. Two monochromatic data sets were generated: with MARS (75-keV MARS) and without MARS (140-keV non-MARS) and evaluated for signs of loosening, using a dedicated radiological score. The Harris Hip Score (HHS) was used to evaluate patients' hip function. Results: The mean radiological score for loosening in the non-MARS group was 16.2, in the MARS group 17.0 and was significantly higher ( P < 0.001). Radiological loosening evaluation in non-MARS images correlated with the HHS score (ρ = 0.43, P = 0.03), whereas there was no correlation between MARS images and HHS (ρ = 0.15, P = 0.47). New MARS-related artifacts, which hinder implant-bone interface evaluation, were found in 75-keV MARS images ("pseudo-loosening" in 33 of 34 prostheses, "ground-glass blurring" in 20 of 32). Conclusions: High-energy monochromatic DECT images are superior to low-energy DECT MARS images in assessment of the potential loosening and correlate better with the clinical examination outcomes. For revision total hip arthroplasty evaluation, 2 data sets should be assessed inseparably because of extra artifacts in MARS images. … (more)
- Is Part Of:
- Journal of computer assisted tomography. Volume 43:Issue 3(2019)
- Journal:
- Journal of computer assisted tomography
- Issue:
- Volume 43:Issue 3(2019)
- Issue Display:
- Volume 43, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 43
- Issue:
- 3
- Issue Sort Value:
- 2019-0043-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-05
- Subjects:
- multidetector computed tomography -- radiography -- dual-energy scanned projection -- artifacts -- arthroplasty -- replacement, hip -- radiographic image enhancement
Tomography -- Periodicals
Tomography -- Periodicals
Tomography
Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/jcat/pages/default.aspx ↗
http://ovidsp.tx.ovid.com ↗
http://www.jcat.org ↗
http://www.rad.bqsm.edu/jcat ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0363-8715 ↗ - DOI:
- 10.1097/RCT.0000000000000850 ↗
- Languages:
- English
- ISSNs:
- 0363-8715
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4963.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12385.xml