Comparison of Volumetric and Bead‐Based Counting of CD34 Cells by Single‐Platform Flow Cytometry. Issue 6 (20th February 2019)
- Record Type:
- Journal Article
- Title:
- Comparison of Volumetric and Bead‐Based Counting of CD34 Cells by Single‐Platform Flow Cytometry. Issue 6 (20th February 2019)
- Main Title:
- Comparison of Volumetric and Bead‐Based Counting of CD34 Cells by Single‐Platform Flow Cytometry
- Authors:
- Saraiva, Luisa
Wang, Lili
Kammel, Martin
Kummrow, Andreas
Atkinson, Eleanor
Lee, Ji Youn
Yalcinkaya, Burhanettin
Akgöz, Muslum
Höckner, Jana
Ruf, Andreas
Engel, Andrea
Zhang, Yu‐Zhong
O'Shea, Orla
Sassi, Maria Paola
Divieto, Carla
Lekishvili, Tamara
Campbell, Jonathan
Liu, Yingying
Wang, Jing
Stebbings, Richard
Gaigalas, Adolfas K.
Rigsby, Peter
Neukammer, Jörg
Vessillier, Sandrine - Abstract:
- Abstract : Background: Over 2, 000 people a year in the United Kingdom need a bone marrow or blood stem cell transplant. It is important to accurately quantify the hematopoietic stem cells to predict whether the transplant will be successful in replenishing the immune system. However, they are present at low frequency, which complicates accurate quantification. The current gold standard method is single‐platform flow cytometry using internal reference counting beads to determine the concentration of CD34 cells. However, volumetric flow cytometers have the ability to measure the acquisition volume, which removes the need for reference beads for calculation of cell concentrations. Method: In this study, we compared both methods for calculating CD34 cell concentrations in volumetric cytometers, using either the volume reading or the number of reference beads for calculation. In addition, the uncertainty of measurement for each method was estimated. Results: The results show that both methods have similar uncertainties of measurement. Regression analysis showed low to no statistical difference in CD34 cell concentrations obtained with each method. Conclusions: Overall, this study suggests that the volumetric method is a valid approach but that the adoption of this technology may be hindered without some form of external calibration of volume readings to increase confidence in the measurement. © 2019 The Authors. Cytometry Part B: Clinical Cytometry published by WileyAbstract : Background: Over 2, 000 people a year in the United Kingdom need a bone marrow or blood stem cell transplant. It is important to accurately quantify the hematopoietic stem cells to predict whether the transplant will be successful in replenishing the immune system. However, they are present at low frequency, which complicates accurate quantification. The current gold standard method is single‐platform flow cytometry using internal reference counting beads to determine the concentration of CD34 cells. However, volumetric flow cytometers have the ability to measure the acquisition volume, which removes the need for reference beads for calculation of cell concentrations. Method: In this study, we compared both methods for calculating CD34 cell concentrations in volumetric cytometers, using either the volume reading or the number of reference beads for calculation. In addition, the uncertainty of measurement for each method was estimated. Results: The results show that both methods have similar uncertainties of measurement. Regression analysis showed low to no statistical difference in CD34 cell concentrations obtained with each method. Conclusions: Overall, this study suggests that the volumetric method is a valid approach but that the adoption of this technology may be hindered without some form of external calibration of volume readings to increase confidence in the measurement. © 2019 The Authors. Cytometry Part B: Clinical Cytometry published by Wiley Periodicals, Inc. on behalf of International Clinical Cytometry Society. … (more)
- Is Part Of:
- Cytometry. Volume 96:Issue 6(2019)
- Journal:
- Cytometry
- Issue:
- Volume 96:Issue 6(2019)
- Issue Display:
- Volume 96, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 96
- Issue:
- 6
- Issue Sort Value:
- 2019-0096-0006-0000
- Page Start:
- 508
- Page End:
- 513
- Publication Date:
- 2019-02-20
- Subjects:
- flow cytometry -- immunotherapy -- rare event detection -- single platform -- standardization -- stem cells -- transplantation
Flow cytometry -- Diagnostic use -- Periodicals
Cytodiagnosis -- Periodicals
616.07582 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/cyto.b.21773 ↗
- Languages:
- English
- ISSNs:
- 1552-4949
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12358.xml