Low Yield of Cerebral Angiography in Adequately Occluded Aneurysms After Flow Diversion. Issue 6 (5th March 2018)
- Record Type:
- Journal Article
- Title:
- Low Yield of Cerebral Angiography in Adequately Occluded Aneurysms After Flow Diversion. Issue 6 (5th March 2018)
- Main Title:
- Low Yield of Cerebral Angiography in Adequately Occluded Aneurysms After Flow Diversion
- Authors:
- Chalouhi, Nohra
Patel, Purvee D
Atallah, Elias
Starke, Robert M
Chitale, Ameet
Lang, Michael
Tjoumakaris, Stavropoula
Hasan, David
Zarzour, Hekmat
Smith, Michelle J
Rosenwasser, Robert
Jabbour, Pascal - Abstract:
- Abstract: BACKGROUND: Flow diversion has emerged as a highly effective treatment for intracranial aneurysms. OBJECTIVE: To assess the yield of further angiographic follow-up in aneurysms that have achieved adequate occlusion after treatment with the Pipeline Embolization Device (PED; Medtronic Inc, Dublin, Ireland). METHODS: This is a single-institution, retrospective study. Inclusion criteria were as follows: (1) patients with 1 or more aneurysms treated with PED, (2) available short-term (<12 mo) follow-up digital subtraction angiography (DSA), (3) complete (100%) or near-complete (>95%) occlusion on short-term follow-up DSA, and (4) available further angiographic follow-up (DSA, Magnetic Resonance Angiography (MRA), or Computed Tomography Angiography (CTA)). RESULTS: A total of 146 patients were identified. Aneurysm size was 8.4 ± 5.1 mm on average. Mean angiographic follow-up time was 29.7 ± 12.2 mo. On short-term follow-up DSA images, 132 (90.4%) had complete aneurysm occlusion and 14 (9.6%) had near-complete occlusion. Four patients (3%) had further DSA follow-up alone, 30 patients (21%) had further DSA and MRA/CTA follow-up, and 112 patients (76%) had further MRA/CTA follow-up alone. On further angiographic follow-up (DSA, MRA, and/or CTA), no patient had a decrease in the degree of aneurysm occlusion (recurrence) or required retreatment. Of the 14 patients with near-complete occlusion on initial DSA images, 7 patients (50%) progressed to complete aneurysm occlusionAbstract: BACKGROUND: Flow diversion has emerged as a highly effective treatment for intracranial aneurysms. OBJECTIVE: To assess the yield of further angiographic follow-up in aneurysms that have achieved adequate occlusion after treatment with the Pipeline Embolization Device (PED; Medtronic Inc, Dublin, Ireland). METHODS: This is a single-institution, retrospective study. Inclusion criteria were as follows: (1) patients with 1 or more aneurysms treated with PED, (2) available short-term (<12 mo) follow-up digital subtraction angiography (DSA), (3) complete (100%) or near-complete (>95%) occlusion on short-term follow-up DSA, and (4) available further angiographic follow-up (DSA, Magnetic Resonance Angiography (MRA), or Computed Tomography Angiography (CTA)). RESULTS: A total of 146 patients were identified. Aneurysm size was 8.4 ± 5.1 mm on average. Mean angiographic follow-up time was 29.7 ± 12.2 mo. On short-term follow-up DSA images, 132 (90.4%) had complete aneurysm occlusion and 14 (9.6%) had near-complete occlusion. Four patients (3%) had further DSA follow-up alone, 30 patients (21%) had further DSA and MRA/CTA follow-up, and 112 patients (76%) had further MRA/CTA follow-up alone. On further angiographic follow-up (DSA, MRA, and/or CTA), no patient had a decrease in the degree of aneurysm occlusion (recurrence) or required retreatment. Of the 14 patients with near-complete occlusion on initial DSA images, 7 patients (50%) progressed to complete aneurysm occlusion on further angiographic follow-up. CONCLUSION: This study did not find any diagnostic yield in repeating cerebral angiography in adequately occluded aneurysms with the PED. We do not recommend repeat angiographic follow-up once aneurysms have achieved complete occlusion with the PED unless clinically warranted. … (more)
- Is Part Of:
- Neurosurgery. Volume 83:Issue 6(2018)
- Journal:
- Neurosurgery
- Issue:
- Volume 83:Issue 6(2018)
- Issue Display:
- Volume 83, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 83
- Issue:
- 6
- Issue Sort Value:
- 2018-0083-0006-0000
- Page Start:
- 1294
- Page End:
- 1297
- Publication Date:
- 2018-03-05
- Subjects:
- Aneurysm -- Flow diversion -- Pipeline Embolization Device -- Angiography
Nervous system -- Surgery -- Periodicals
617.48005 - Journal URLs:
- https://academic.oup.com/neurosurgery ↗
http://www.neurosurgery-online.com ↗
https://journals.lww.com/neurosurgery/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1093/neuros/nyx625 ↗
- Languages:
- English
- ISSNs:
- 0148-396X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.582000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12369.xml