Effects of a 3D-printed orthosis compared to a low-temperature thermoplastic plate orthosis on wrist flexor spasticity in chronic hemiparetic stroke patients: a randomized controlled trial. (February 2020)
- Record Type:
- Journal Article
- Title:
- Effects of a 3D-printed orthosis compared to a low-temperature thermoplastic plate orthosis on wrist flexor spasticity in chronic hemiparetic stroke patients: a randomized controlled trial. (February 2020)
- Main Title:
- Effects of a 3D-printed orthosis compared to a low-temperature thermoplastic plate orthosis on wrist flexor spasticity in chronic hemiparetic stroke patients: a randomized controlled trial
- Authors:
- Zheng, Yanan
Liu, Gongliang
Yu, Long
Wang, Yanmin
Fang, Yuan
Shen, Yikang
Huang, Xiuling
Qiao, Lei
Yang, Jianzhong
Zhang, Ying
Hua, Zikai - Abstract:
- Objective: The aim of this study was to compare the effects of two kinds of wrist-hand orthosis on wrist flexor spasticity in chronic stroke patients. Design: This is a randomized controlled trial. Setting: The study was conducted in a rehabilitation center. Participants: A total of 40 chronic hemiparetic stroke patients with wrist flexor spasticity were involved in the study. Interventions: Patients were randomly assigned to either an experimental group (conventional rehabilitation therapy + 3D-printed orthosis, 20 patients) or a control group (conventional rehabilitation therapy + low-temperature thermoplastic plate orthosis, 20 patients). The time of wearing orthosis was about 4–8 hours per day for six weeks. Main measures: Primary outcome measure : Modified Ashworth Scale was assessed three times (at baseline, three weeks, and six weeks). Secondary outcome measures : passive range of motion, Fugl-Meyer Assessment score, visual analogue scale score, and the swelling score were assessed twice (at baseline and six weeks). The subjective feeling score was assessed at six weeks. Results: No significant difference was found between the two groups in the change of Modified Ashworth Scale scores at three weeks (15% versus 25%, P = 0.496). At six weeks, the Modified Ashworth Scale scores (65% versus 30%, P = 0.02), passive range of wrist extension ( P < 0.001), ulnar deviation ( P = 0.028), Fugl-Meyer Assessment scores ( P < 0.001), and swelling scores ( P < 0.001) showedObjective: The aim of this study was to compare the effects of two kinds of wrist-hand orthosis on wrist flexor spasticity in chronic stroke patients. Design: This is a randomized controlled trial. Setting: The study was conducted in a rehabilitation center. Participants: A total of 40 chronic hemiparetic stroke patients with wrist flexor spasticity were involved in the study. Interventions: Patients were randomly assigned to either an experimental group (conventional rehabilitation therapy + 3D-printed orthosis, 20 patients) or a control group (conventional rehabilitation therapy + low-temperature thermoplastic plate orthosis, 20 patients). The time of wearing orthosis was about 4–8 hours per day for six weeks. Main measures: Primary outcome measure : Modified Ashworth Scale was assessed three times (at baseline, three weeks, and six weeks). Secondary outcome measures : passive range of motion, Fugl-Meyer Assessment score, visual analogue scale score, and the swelling score were assessed twice (at baseline and six weeks). The subjective feeling score was assessed at six weeks. Results: No significant difference was found between the two groups in the change of Modified Ashworth Scale scores at three weeks (15% versus 25%, P = 0.496). At six weeks, the Modified Ashworth Scale scores (65% versus 30%, P = 0.02), passive range of wrist extension ( P < 0.001), ulnar deviation ( P = 0.028), Fugl-Meyer Assessment scores ( P < 0.001), and swelling scores ( P < 0.001) showed significant changes between the experimental group and the control group. No significant difference was found between the two groups in the change of visual analogue scale scores ( P = 0.637) and the subjective feeling scores ( P = 0.243). Conclusion: 3D-printed orthosis showed greater changes than low-temperature thermoplastic plate orthosis in reducing spasticity and swelling, improving motor function of the wrist and passive range of wrist extension for stroke patients. … (more)
- Is Part Of:
- Clinical rehabilitation. Volume 34:Number 2(2020)
- Journal:
- Clinical rehabilitation
- Issue:
- Volume 34:Number 2(2020)
- Issue Display:
- Volume 34, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 34
- Issue:
- 2
- Issue Sort Value:
- 2020-0034-0002-0000
- Page Start:
- 194
- Page End:
- 204
- Publication Date:
- 2020-02
- Subjects:
- Stroke rehabilitation -- spasticity -- printing -- three-dimensional -- orthotic devices
Medical rehabilitation -- Periodicals
617.03 - Journal URLs:
- http://cre.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0269215519885174 ↗
- Languages:
- English
- ISSNs:
- 0269-2155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12342.xml