Lumpectomy Specimen Radiography: Does Orientation or 3-Dimensional Tomosynthesis Improve Margin Assessment?. Issue 3 (August 2019)
- Record Type:
- Journal Article
- Title:
- Lumpectomy Specimen Radiography: Does Orientation or 3-Dimensional Tomosynthesis Improve Margin Assessment?. Issue 3 (August 2019)
- Main Title:
- Lumpectomy Specimen Radiography: Does Orientation or 3-Dimensional Tomosynthesis Improve Margin Assessment?
- Authors:
- Mario, Julia
Venkataraman, Shambhavi
Fein-Zachary, Valerie
Knox, Mark
Brook, Alexander
Slanetz, Priscilla - Abstract:
- Purpose: Our purpose was twofold. First, we sought to determine whether 2 orthogonal oriented views of excised breast cancer specimens could improve surgical margin assessment compared to a single unoriented view. Second, we sought to determine whether 3D tomosynthesis could improve surgical margin assessment compared to 2D mammography alone. Materials and Methods: Forty-one consecutive specimens were prospectively imaged using 4 protocols: single view unoriented 2D image acquired on a specimen unit (1VSU), 2 orthogonal oriented 2D images acquired on the specimen unit (2VSU), 2 orthogonal oriented 2D images acquired on a mammogram unit (2V2DMU), and 2 orthogonal oriented 3D images acquired on the mammogram unit (2V3DMU). Three breast imagers randomly assessed surgical margin of the 41 specimens with each protocol. Surgical margin per histopathology was considered the gold standard. Results: The average area under the curve (AUC) was 0.60 for 1VSU, 0.66 for 2VSU, 0.68 for 2V2DMU, and 0.60 for 2V3DMU. Comparing AUCs for 2VSU vs 1VSU by reader showed improved diagnostic accuracy using 2VSU; however, this difference was only statistically significant for reader 3 (0.73 vs 0.63, P = .0455). Comparing AUCs for 2V3DMU vs 2V2DMU by reader showed mixed results, with reader 1 demonstrating increased accuracy (0.72 vs 0.68, P = .5984), while readers 2 and 3 demonstrated decreased accuracy (0.50 vs 0.62, P = .1089 and 0.58 vs 0.75, P = .0269). Conclusions: 2VSU showed improved accuracyPurpose: Our purpose was twofold. First, we sought to determine whether 2 orthogonal oriented views of excised breast cancer specimens could improve surgical margin assessment compared to a single unoriented view. Second, we sought to determine whether 3D tomosynthesis could improve surgical margin assessment compared to 2D mammography alone. Materials and Methods: Forty-one consecutive specimens were prospectively imaged using 4 protocols: single view unoriented 2D image acquired on a specimen unit (1VSU), 2 orthogonal oriented 2D images acquired on the specimen unit (2VSU), 2 orthogonal oriented 2D images acquired on a mammogram unit (2V2DMU), and 2 orthogonal oriented 3D images acquired on the mammogram unit (2V3DMU). Three breast imagers randomly assessed surgical margin of the 41 specimens with each protocol. Surgical margin per histopathology was considered the gold standard. Results: The average area under the curve (AUC) was 0.60 for 1VSU, 0.66 for 2VSU, 0.68 for 2V2DMU, and 0.60 for 2V3DMU. Comparing AUCs for 2VSU vs 1VSU by reader showed improved diagnostic accuracy using 2VSU; however, this difference was only statistically significant for reader 3 (0.73 vs 0.63, P = .0455). Comparing AUCs for 2V3DMU vs 2V2DMU by reader showed mixed results, with reader 1 demonstrating increased accuracy (0.72 vs 0.68, P = .5984), while readers 2 and 3 demonstrated decreased accuracy (0.50 vs 0.62, P = .1089 and 0.58 vs 0.75, P = .0269). Conclusions: 2VSU showed improved accuracy in surgical margin prediction compared to 1VSU, although this was not statistically significant for all readers. 3D tomosynthesis did not improve surgical margin assessment. … (more)
- Is Part Of:
- Canadian Association of Radiologists journal. Volume 70:Issue 3(2019)
- Journal:
- Canadian Association of Radiologists journal
- Issue:
- Volume 70:Issue 3(2019)
- Issue Display:
- Volume 70, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 70
- Issue:
- 3
- Issue Sort Value:
- 2019-0070-0003-0000
- Page Start:
- 282
- Page End:
- 291
- Publication Date:
- 2019-08
- Subjects:
- Breast cancer specimen -- Digital breast tomosynthesis -- Orthogonal views -- Surgical margins -- Lumpectomy specimen radiography
Radiology, Medical -- Periodicals
Radiology, Medical -- Canada -- Periodicals
616.0757 - Journal URLs:
- http://bibpurl.oclc.org/web/10153 ↗
http://www.carjonline.org ↗
https://journals.sagepub.com/home/caj ↗
http://www.elsevier.com/journals ↗
http://www.elsevier.com/wps/find/journaldescription.cws_home/718496/description#description ↗ - DOI:
- 10.1016/j.carj.2019.03.005 ↗
- Languages:
- English
- ISSNs:
- 0846-5371
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4722.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12345.xml