Radiation Dose Reduction with a Low-Tube Voltage Technique for Pediatric Chest Computed Tomographic Angiography Based on the Contrast-to-Noise Ratio Index. Issue 4 (November 2018)
- Record Type:
- Journal Article
- Title:
- Radiation Dose Reduction with a Low-Tube Voltage Technique for Pediatric Chest Computed Tomographic Angiography Based on the Contrast-to-Noise Ratio Index. Issue 4 (November 2018)
- Main Title:
- Radiation Dose Reduction with a Low-Tube Voltage Technique for Pediatric Chest Computed Tomographic Angiography Based on the Contrast-to-Noise Ratio Index
- Authors:
- Masuda, Takanori
Funama, Yoshinori
Nakaura, Takeshi
Tahara, Masahiro
Yamashita, Yukari
Kiguchi, Masao
Imada, Naoyuki
Sato, Tomoyasu
Awai, Kazuo - Abstract:
- Introduction: The aim of this study was to evaluate the radiation dose and image quality at low tube-voltage pediatric chest computed tomographic angiography (CTA) that applies the same contrast-to-noise ratio (CNR) index as the standard tube voltage technique. Materials and Methods: Contrast-enhanced chest CTA scans of 100 infants were acquired on a 64-row multidetector computed tomography (MDCT) scanner. In the retrospective study, we evaluated 50 images acquired at 120 kVp; the image noise level was set at 25 Hounsfield units. In the prospective study, we used an 80-kVp protocol; the image noise level was 40 Hounsfield units because the iodine contrast was 1.6 times higher than on 120-kVp scans; the CNR was as in the 120-kVp protocol. We compared the CT number, image noise, CT dose index volume (CTDIvol ), and the dose-length product on scans acquired with the 2 protocols. A diagnostic radiologist and a pediatric cardiologist visually evaluated all CTA images. Results: The mean CTDIvol and the mean dose-length product were 0.5 mGy and 7.8 mGy-cm for 80- and 1.2 mGy and 20.8 mGy-cm for 120-kVp scans, respectively ( P < .001). The mean CTDIvol was 42% lower at 80 kVp than at 120 kVp, and there was no significant difference in the visual scores assigned to the CTA images ( P = .28). Conclusions: With the CNR index being the same at 80-kVp and 120-kVp imaging, the radiation dose delivered to infants subjected to chest CTA can be reduced without degradation of the imageIntroduction: The aim of this study was to evaluate the radiation dose and image quality at low tube-voltage pediatric chest computed tomographic angiography (CTA) that applies the same contrast-to-noise ratio (CNR) index as the standard tube voltage technique. Materials and Methods: Contrast-enhanced chest CTA scans of 100 infants were acquired on a 64-row multidetector computed tomography (MDCT) scanner. In the retrospective study, we evaluated 50 images acquired at 120 kVp; the image noise level was set at 25 Hounsfield units. In the prospective study, we used an 80-kVp protocol; the image noise level was 40 Hounsfield units because the iodine contrast was 1.6 times higher than on 120-kVp scans; the CNR was as in the 120-kVp protocol. We compared the CT number, image noise, CT dose index volume (CTDIvol ), and the dose-length product on scans acquired with the 2 protocols. A diagnostic radiologist and a pediatric cardiologist visually evaluated all CTA images. Results: The mean CTDIvol and the mean dose-length product were 0.5 mGy and 7.8 mGy-cm for 80- and 1.2 mGy and 20.8 mGy-cm for 120-kVp scans, respectively ( P < .001). The mean CTDIvol was 42% lower at 80 kVp than at 120 kVp, and there was no significant difference in the visual scores assigned to the CTA images ( P = .28). Conclusions: With the CNR index being the same at 80-kVp and 120-kVp imaging, the radiation dose delivered to infants subjected to chest CTA can be reduced without degradation of the image quality. … (more)
- Is Part Of:
- Canadian Association of Radiologists journal. Volume 69:Issue 4(2018)
- Journal:
- Canadian Association of Radiologists journal
- Issue:
- Volume 69:Issue 4(2018)
- Issue Display:
- Volume 69, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 69
- Issue:
- 4
- Issue Sort Value:
- 2018-0069-0004-0000
- Page Start:
- 390
- Page End:
- 396
- Publication Date:
- 2018-11
- Subjects:
- Radiation dose reduction -- Contrast-to-noise ratio -- Pediatric computed tomographic angiography -- Low-tube-voltage
Radiology, Medical -- Periodicals
Radiology, Medical -- Canada -- Periodicals
616.0757 - Journal URLs:
- http://bibpurl.oclc.org/web/10153 ↗
http://www.carjonline.org ↗
https://journals.sagepub.com/home/caj ↗
http://www.elsevier.com/journals ↗
http://www.elsevier.com/wps/find/journaldescription.cws_home/718496/description#description ↗ - DOI:
- 10.1016/j.carj.2018.05.004 ↗
- Languages:
- English
- ISSNs:
- 0846-5371
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4722.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12353.xml