Post–Vacuum-Assisted Stereotactic Core Biopsy Clip Displacement: A Comparison between Commercially Available Clips and Surgical Clip. Issue 1 (February 2018)
- Record Type:
- Journal Article
- Title:
- Post–Vacuum-Assisted Stereotactic Core Biopsy Clip Displacement: A Comparison between Commercially Available Clips and Surgical Clip. Issue 1 (February 2018)
- Main Title:
- Post–Vacuum-Assisted Stereotactic Core Biopsy Clip Displacement: A Comparison between Commercially Available Clips and Surgical Clip
- Authors:
- Yen, Peggy
Dumas, Sandra
Albert, Arianne
Gordon, Paula - Abstract:
- Purpose: The placement of localization clips following percutaneous biopsy is a standard practice for a variety of situations. Subsequent clip displacement creates challenges for imaging surveillance and surgical planning, and may cause confusion amongst radiologists and between surgeons and radiologists. Many causes have been attributed for this phenomenon including the commonly accepted "accordion effect." Herein, we investigate the performance of a low cost surgical clip system against 4 commercially available clips. Methods: We retrospectively reviewed 2112 patients who underwent stereotactic vacuum-assisted core biopsy followed by clip placement between January 2013 and June 2016. The primary performance parameter compared was displacement >10 mm following vacuum-assisted stereotactic core biopsy. Within the group of clips that had displaced, the magnitude of displacement was compared. Results: There was a significant difference in displacement among the clip types ( P < .0001) with significant pairwise comparisons between pediatric surgical clips and SecureMark (38% vs 28%; P = .001) and SenoMark (38% vs 27%; P = .0001) in the proportion displaced. The surgical clips showed a significant magnitude of displacement of approximately 25% greater average distance displaced. Conclusions: As a whole, the commercial clips performed better than the surgical clip after stereotactic vacuum-assisted core biopsy suggesting the surrounding outer component acts to anchor the centralPurpose: The placement of localization clips following percutaneous biopsy is a standard practice for a variety of situations. Subsequent clip displacement creates challenges for imaging surveillance and surgical planning, and may cause confusion amongst radiologists and between surgeons and radiologists. Many causes have been attributed for this phenomenon including the commonly accepted "accordion effect." Herein, we investigate the performance of a low cost surgical clip system against 4 commercially available clips. Methods: We retrospectively reviewed 2112 patients who underwent stereotactic vacuum-assisted core biopsy followed by clip placement between January 2013 and June 2016. The primary performance parameter compared was displacement >10 mm following vacuum-assisted stereotactic core biopsy. Within the group of clips that had displaced, the magnitude of displacement was compared. Results: There was a significant difference in displacement among the clip types ( P < .0001) with significant pairwise comparisons between pediatric surgical clips and SecureMark (38% vs 28%; P = .001) and SenoMark (38% vs 27%; P = .0001) in the proportion displaced. The surgical clips showed a significant magnitude of displacement of approximately 25% greater average distance displaced. Conclusions: As a whole, the commercial clips performed better than the surgical clip after stereotactic vacuum-assisted core biopsy suggesting the surrounding outer component acts to anchor the central clip and minimizes clip displacement. The same should apply to tomosynthesis-guided biopsy. … (more)
- Is Part Of:
- Canadian Association of Radiologists journal. Volume 69:Issue 1(2018)
- Journal:
- Canadian Association of Radiologists journal
- Issue:
- Volume 69:Issue 1(2018)
- Issue Display:
- Volume 69, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 69
- Issue:
- 1
- Issue Sort Value:
- 2018-0069-0001-0000
- Page Start:
- 10
- Page End:
- 15
- Publication Date:
- 2018-02
- Subjects:
- Clip displacement -- Stereotactic biopsy
Radiology, Medical -- Periodicals
Radiology, Medical -- Canada -- Periodicals
616.0757 - Journal URLs:
- http://bibpurl.oclc.org/web/10153 ↗
http://www.carjonline.org ↗
https://journals.sagepub.com/home/caj ↗
http://www.elsevier.com/journals ↗
http://www.elsevier.com/wps/find/journaldescription.cws_home/718496/description#description ↗ - DOI:
- 10.1016/j.carj.2017.08.004 ↗
- Languages:
- English
- ISSNs:
- 0846-5371
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4722.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12346.xml