Initial Experience Using a Telerobotic Ultrasound System for Adult Abdominal Sonography. Issue 3 (August 2017)
- Record Type:
- Journal Article
- Title:
- Initial Experience Using a Telerobotic Ultrasound System for Adult Abdominal Sonography. Issue 3 (August 2017)
- Main Title:
- Initial Experience Using a Telerobotic Ultrasound System for Adult Abdominal Sonography
- Authors:
- Adams, Scott J.
Burbridge, Brent E.
Badea, Andreea
Langford, Leanne
Vergara, Vincent
Bryce, Rhonda
Bustamante, Luis
Mendez, Ivar M.
Babyn, Paul S. - Abstract:
- Purpose: The study sought to assess the feasibility of performing adult abdominal examinations using a telerobotic ultrasound system in which radiologists or sonographers can control fine movements of a transducer and all ultrasound settings from a remote location. Methods: Eighteen patients prospectively underwent a conventional sonography examination (using EPIQ 5 [Philips] or LOGIQ E9 [GE Healthcare]) followed by a telerobotic sonography examination (using the MELODY System [AdEchoTech] and SonixTablet [BK Ultrasound]) according to a standardized abdominal imaging protocol. For telerobotic examinations, patients were scanned remotely by a sonographer 2.75 km away. Conventional examinations were read independently from telerobotic examinations. Image quality and acceptability to patients and sonographers was assessed. Results: Ninety-two percent of organs visualized on conventional examinations were sufficiently visualized on telerobotic examinations. Five pathological findings were identified on both telerobotic and conventional examinations, 3 findings were identified using only conventional sonography, and 2 findings were identified using only telerobotic sonography. A paired sample t test showed no significant difference between the 2 modalities in measurements of the liver, spleen, and diameter of the proximal aorta; however, telerobotic assessments overestimated distal aorta and common bile duct diameters and underestimated kidney lengths ( P values < .05). AllPurpose: The study sought to assess the feasibility of performing adult abdominal examinations using a telerobotic ultrasound system in which radiologists or sonographers can control fine movements of a transducer and all ultrasound settings from a remote location. Methods: Eighteen patients prospectively underwent a conventional sonography examination (using EPIQ 5 [Philips] or LOGIQ E9 [GE Healthcare]) followed by a telerobotic sonography examination (using the MELODY System [AdEchoTech] and SonixTablet [BK Ultrasound]) according to a standardized abdominal imaging protocol. For telerobotic examinations, patients were scanned remotely by a sonographer 2.75 km away. Conventional examinations were read independently from telerobotic examinations. Image quality and acceptability to patients and sonographers was assessed. Results: Ninety-two percent of organs visualized on conventional examinations were sufficiently visualized on telerobotic examinations. Five pathological findings were identified on both telerobotic and conventional examinations, 3 findings were identified using only conventional sonography, and 2 findings were identified using only telerobotic sonography. A paired sample t test showed no significant difference between the 2 modalities in measurements of the liver, spleen, and diameter of the proximal aorta; however, telerobotic assessments overestimated distal aorta and common bile duct diameters and underestimated kidney lengths ( P values < .05). All patients responded that they would be willing to have another telerobotic examination. Conclusions: A telerobotic ultrasound system is feasible for performing abdominal ultrasound examinations at a distant location with minimal training and setup requirements and a moderate learning curve. Telerobotic sonography (robotic telesonography) may open up the possibility of remote ultrasound clinics for communities that lack skilled sonographers and radiologists, thereby improving access to care. … (more)
- Is Part Of:
- Canadian Association of Radiologists journal. Volume 68:Issue 3(2017)
- Journal:
- Canadian Association of Radiologists journal
- Issue:
- Volume 68:Issue 3(2017)
- Issue Display:
- Volume 68, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 68
- Issue:
- 3
- Issue Sort Value:
- 2017-0068-0003-0000
- Page Start:
- 308
- Page End:
- 314
- Publication Date:
- 2017-08
- Subjects:
- Remote presence -- Robotics -- Teleradiology -- Telerobotic -- Telesonography -- Ultrasound
Radiology, Medical -- Periodicals
Radiology, Medical -- Canada -- Periodicals
616.0757 - Journal URLs:
- http://bibpurl.oclc.org/web/10153 ↗
http://www.carjonline.org ↗
https://journals.sagepub.com/home/caj ↗
http://www.elsevier.com/journals ↗
http://www.elsevier.com/wps/find/journaldescription.cws_home/718496/description#description ↗ - DOI:
- 10.1016/j.carj.2016.08.002 ↗
- Languages:
- English
- ISSNs:
- 0846-5371
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4722.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12349.xml