Contralateral Eye Comparison Between 2 Cap Thicknesses in Small Incision Lenticule Extraction: 110 Versus 130 μm. Issue 5 (May 2019)
- Record Type:
- Journal Article
- Title:
- Contralateral Eye Comparison Between 2 Cap Thicknesses in Small Incision Lenticule Extraction: 110 Versus 130 μm. Issue 5 (May 2019)
- Main Title:
- Contralateral Eye Comparison Between 2 Cap Thicknesses in Small Incision Lenticule Extraction
- Authors:
- Wu, Fang
Yin, Houfa
Yang, Yabo - Abstract:
- Abstract : Purpose: To evaluate the posterior corneal elevation (PCE) and biomechanical changes after small incision lenticule extraction (SMILE) at depths of 110 μm and 130 μm. Methods: One hundred sixteen eyes from 58 consecutive patients who underwent SMILE were included in this prospective study. Each patient underwent SMILE in one eye to a depth of 110 μm and in the other eye to a depth of 130 μm. A Scheimpflug camera and Hartmann-Shack WASCA aberrometer were used to assess the PCE and wavefront aberrations, respectively, before SMILE and at 1 and 3 months after surgery. The PCE was analyzed along 3 optical zones (apex and 2 and 4 mm diameters) as a function of the meridian. Dynamic Scheimpflug imaging was used to evaluate the biomechanics preoperatively and at 1 day, 1 month, and 3 months postoperatively. Results: No significant difference was found in either vision correction or corneal biomechanics between the 2 groups. In both groups, the PCE became significantly flattened at the apex and at 2 mm annulus 1 month postoperatively, especially for the 110-μm cap group. Three months postoperatively, the 110-μm cap group was still flattened significantly, whereas the displacement at the apex in the 130-μm cap group had disappeared. There was no significant difference in wavefront aberrations between the groups after surgery, except in the vertical coma ( P < 0.001). Conclusions: The differences in corneal biomechanics between the 110-μm cap group and 130-μm cap group wereAbstract : Purpose: To evaluate the posterior corneal elevation (PCE) and biomechanical changes after small incision lenticule extraction (SMILE) at depths of 110 μm and 130 μm. Methods: One hundred sixteen eyes from 58 consecutive patients who underwent SMILE were included in this prospective study. Each patient underwent SMILE in one eye to a depth of 110 μm and in the other eye to a depth of 130 μm. A Scheimpflug camera and Hartmann-Shack WASCA aberrometer were used to assess the PCE and wavefront aberrations, respectively, before SMILE and at 1 and 3 months after surgery. The PCE was analyzed along 3 optical zones (apex and 2 and 4 mm diameters) as a function of the meridian. Dynamic Scheimpflug imaging was used to evaluate the biomechanics preoperatively and at 1 day, 1 month, and 3 months postoperatively. Results: No significant difference was found in either vision correction or corneal biomechanics between the 2 groups. In both groups, the PCE became significantly flattened at the apex and at 2 mm annulus 1 month postoperatively, especially for the 110-μm cap group. Three months postoperatively, the 110-μm cap group was still flattened significantly, whereas the displacement at the apex in the 130-μm cap group had disappeared. There was no significant difference in wavefront aberrations between the groups after surgery, except in the vertical coma ( P < 0.001). Conclusions: The differences in corneal biomechanics between the 110-μm cap group and 130-μm cap group were small; however, the superficial lenticule might cause displacement of the PCE to be more persistent in one eye than in the other. … (more)
- Is Part Of:
- Cornea. Volume 38:Issue 5(2019)
- Journal:
- Cornea
- Issue:
- Volume 38:Issue 5(2019)
- Issue Display:
- Volume 38, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 38
- Issue:
- 5
- Issue Sort Value:
- 2019-0038-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-05
- Subjects:
- SMILE -- biomechanics -- cap -- posterior corneal elevation -- wavefront aberrations
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000001835 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12331.xml