Computation Speeds and Memory Requirements of Mesh-Type ICRP Reference Computational Phantoms in Geant4, MCNP6, and PHITS. Issue 5 (May 2019)
- Record Type:
- Journal Article
- Title:
- Computation Speeds and Memory Requirements of Mesh-Type ICRP Reference Computational Phantoms in Geant4, MCNP6, and PHITS. Issue 5 (May 2019)
- Main Title:
- Computation Speeds and Memory Requirements of Mesh-Type ICRP Reference Computational Phantoms in Geant4, MCNP6, and PHITS
- Authors:
- Yeom, Yeon Soo
Han, Min Cheol
Choi, Chansoo
Han, Haegin
Shin, Bangho
Furuta, Takuya
Kim, Chan Hyeong - Abstract:
- Abstract : Abstract: Recently, Task Group 103 of the International Commission on Radiological Protection completed the development of new adult male and female mesh-type reference computational phantoms, which are planned for use in future International Commission on Radiological Protection dose coefficient calculations. In the present study, the performance of major Monte Carlo particle transport codes, i.e., Geant4, MCNP6, and PHITS, were investigated for the mesh-type reference computational phantoms by performing transport simulations of photons, electrons, neutrons, and helium ions for some external and internal exposures, and simultaneously measuring the memory usage, initialization time, and computation speed of the adult male mesh-type reference computational phantom in the codes. The measured results were then compared with the values measured with the current adult male voxel-type reference computational phantom in International Commission on Radiological Protection Publication 110 as well as five voxel phantoms produced from the adult male mesh-type reference computational phantom with different voxel resolutions, i.e., 0.1 × 0.1 × 0.1 mm 3, 0.6 × 0.6 × 0.6 mm 3, 1 × 1 × 1 mm 3, 2 × 2 × 2 mm 3, and 4 × 4 × 4 mm 3 . From the results, it was found that in all of the codes, the memory usage of the mesh-type reference computational phantom is greater than that of the voxel-type reference computational phantom and the lowest resolution voxelized phantom, but it isAbstract : Abstract: Recently, Task Group 103 of the International Commission on Radiological Protection completed the development of new adult male and female mesh-type reference computational phantoms, which are planned for use in future International Commission on Radiological Protection dose coefficient calculations. In the present study, the performance of major Monte Carlo particle transport codes, i.e., Geant4, MCNP6, and PHITS, were investigated for the mesh-type reference computational phantoms by performing transport simulations of photons, electrons, neutrons, and helium ions for some external and internal exposures, and simultaneously measuring the memory usage, initialization time, and computation speed of the adult male mesh-type reference computational phantom in the codes. The measured results were then compared with the values measured with the current adult male voxel-type reference computational phantom in International Commission on Radiological Protection Publication 110 as well as five voxel phantoms produced from the adult male mesh-type reference computational phantom with different voxel resolutions, i.e., 0.1 × 0.1 × 0.1 mm 3, 0.6 × 0.6 × 0.6 mm 3, 1 × 1 × 1 mm 3, 2 × 2 × 2 mm 3, and 4 × 4 × 4 mm 3 . From the results, it was found that in all of the codes, the memory usage of the mesh-type reference computational phantom is greater than that of the voxel-type reference computational phantom and the lowest resolution voxelized phantom, but it is sufficiently lower than the maximum memory, 64 GB, that can be installed in a personal computer. The required initialization time of the mesh-type reference computational phantom and of the voxel-type reference computational phantom and voxelized phantoms in resolutions lower than 0.6 × 0.6 × 0.6 mm 3 was less than a few minutes in all of the codes. As for the computation speed among the codes, MCNP6 showed the worst performance for the mesh-type reference computational phantom, which was slower than that for the voxel-type reference computational phantom by up to ~50 times and slower than that for all of the voxelized phantoms by up to ~40 times. By contrast, PHITS showed the best performance for the mesh-type reference computational phantom, which was faster than that for the voxel-type reference computational phantom by up to ~3 times and faster than that for all of the voxelized phantoms by up to ~20 times. This high performance of PHITS is indeed encouraging considering that it is used nowadays by the International Commission on Radiological Protection for most dose coefficient calculations. … (more)
- Is Part Of:
- Health physics. Volume 116:Issue 5(2019:May)
- Journal:
- Health physics
- Issue:
- Volume 116:Issue 5(2019:May)
- Issue Display:
- Volume 116, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 116
- Issue:
- 5
- Issue Sort Value:
- 2019-0116-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-05
- Subjects:
- computer calculations -- International Commission on Radiological Protection -- Monte Carlo -- phantom
Biophysics -- Periodicals
Health Physics -- periodicals
Radiation Protection -- periodicals
Radiotherapy -- periodicals
Medische fysica
Electronic journals
612.01448 - Journal URLs:
- http://journals.lww.com/health-physics/pages/default.aspx ↗
http://www.health-physics.com ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/HP.0000000000000999 ↗
- Languages:
- English
- ISSNs:
- 0017-9078
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4275.100000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12336.xml