Cost-effectiveness analysis of short-duration dual antiplatelet therapy with newer drug-eluting stent platforms versus longer-duration dual antiplatelet therapy with a second-generation drug-eluting stent in elective percutaneous coronary intervention. Issue 3 (May 2019)
- Record Type:
- Journal Article
- Title:
- Cost-effectiveness analysis of short-duration dual antiplatelet therapy with newer drug-eluting stent platforms versus longer-duration dual antiplatelet therapy with a second-generation drug-eluting stent in elective percutaneous coronary intervention. Issue 3 (May 2019)
- Main Title:
- Cost-effectiveness analysis of short-duration dual antiplatelet therapy with newer drug-eluting stent platforms versus longer-duration dual antiplatelet therapy with a second-generation drug-eluting stent in elective percutaneous coronary intervention
- Authors:
- Galper, Benjamin Z.
Reynolds, Matthew R.
Garg, Pallav
Secemsky, Eric A.
Valsdottir, Linda R.
Cohen, David J.
Yeh, Robert W. - Abstract:
- Abstract : Background: The cost-effectiveness of newer drug-eluting stents (DES) such as biodegradable-polymer or polymer-free stents with shorter dual antiplatelet therapy (DAPT) duration is unknown. We evaluated the cost-effectiveness of treatment with newer DES that may allow for shorter DAPT duration. Patients and methods: We performed a cost-effectiveness analysis of treatment with newer DES platforms followed by 1 or 3 months of DAPT compared with standard second-generation DES followed by 6 or 12 months of DAPT in patients with stable coronary disease. A Markov model simulated distinct health states over a lifetime. Probabilistic sensitivity analysis and one-way sensitivity analyses were performed. A high-risk bleeding scenario was also evaluated. Results: Among patients with typical bleeding risk, second-generation DES and 6 months of DAPT was less expensive and resulted in marginally higher quality-adjusted life years compared with other strategies. A newer DES platform and 3 months of DAPT was preferred when the risk of fatal bleeding was two times greater than baseline, or when bleeding increased long-term mortality by a factor of 1.5. In a probabilistic sensitivity analysis, second-generation DES and 6 months of DAPT was preferred in 58% of iterations, whereas in a high-risk bleeding patient scenario, a newer DES and 3 months of DAPT was preferred in 52% of iterations. Conclusion: A DES that allows 3 months of DAPT without increasing stent-related events isAbstract : Background: The cost-effectiveness of newer drug-eluting stents (DES) such as biodegradable-polymer or polymer-free stents with shorter dual antiplatelet therapy (DAPT) duration is unknown. We evaluated the cost-effectiveness of treatment with newer DES that may allow for shorter DAPT duration. Patients and methods: We performed a cost-effectiveness analysis of treatment with newer DES platforms followed by 1 or 3 months of DAPT compared with standard second-generation DES followed by 6 or 12 months of DAPT in patients with stable coronary disease. A Markov model simulated distinct health states over a lifetime. Probabilistic sensitivity analysis and one-way sensitivity analyses were performed. A high-risk bleeding scenario was also evaluated. Results: Among patients with typical bleeding risk, second-generation DES and 6 months of DAPT was less expensive and resulted in marginally higher quality-adjusted life years compared with other strategies. A newer DES platform and 3 months of DAPT was preferred when the risk of fatal bleeding was two times greater than baseline, or when bleeding increased long-term mortality by a factor of 1.5. In a probabilistic sensitivity analysis, second-generation DES and 6 months of DAPT was preferred in 58% of iterations, whereas in a high-risk bleeding patient scenario, a newer DES and 3 months of DAPT was preferred in 52% of iterations. Conclusion: A DES that allows 3 months of DAPT without increasing stent-related events is likely to be cost-effective among patients at elevated risk of bleeding, but not in patients with average bleeding risk. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Coronary artery disease. Volume 30:Issue 3(2019:May)
- Journal:
- Coronary artery disease
- Issue:
- Volume 30:Issue 3(2019:May)
- Issue Display:
- Volume 30, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 3
- Issue Sort Value:
- 2019-0030-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-05
- Subjects:
- absorbable implants -- coronary disease -- drug therapy
Coronary heart disease -- Periodicals
Coronary Disease -- Indexes
Coronary Disease -- Periodicals
616.123005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00019501-000000000-00000 ↗
http://www.coronary-artery.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MCA.0000000000000694 ↗
- Languages:
- English
- ISSNs:
- 0954-6928
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3472.049000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12332.xml