Fourier Domain Optical Coherence Tomography With 3D and En Face Imaging of the Punctum and Vertical Canaliculus: A Step Toward Establishing a Normative Database. Issue 3 (May 2016)
- Record Type:
- Journal Article
- Title:
- Fourier Domain Optical Coherence Tomography With 3D and En Face Imaging of the Punctum and Vertical Canaliculus: A Step Toward Establishing a Normative Database. Issue 3 (May 2016)
- Main Title:
- Fourier Domain Optical Coherence Tomography With 3D and En Face Imaging of the Punctum and Vertical Canaliculus
- Authors:
- Kamal, Saurabh
Ali, Mohammad Javed
Ali, Mohammad Hasnat
Naik, Milind N - Abstract:
- Abstract : Purpose: To report the features of Fourier domain optical coherence tomography imaging of the normal punctum and vertical canaliculus. Methods: Prospective, interventional series of consecutive healthy and asymptomatic adults, who volunteered for optical coherence tomography imaging, were included in the study. Fourier domain optical coherence tomography images of the punctum and vertical canaliculus along with 3D and En face images were captured using the RTVue scanner with a corneal adaptor module and a wide-angled lens. Maximum punctal diameter, mid-canalicular diameter, and vertical canalicular height were calculated. Statistical analysis was performed using Pearson correlation test, and scatter plot matrices were analyzed. Results: A total of 103 puncta of 52 healthy subjects were studied. Although all the images could depict the punctum and vertical canaliculus and all the desired measurements could be obtained, occasional tear debris within the canaliculus was found to be interfering with the imaging. The mean maximum punctal diameter, mid-canalicular diameter, and vertical canalicular height were recorded as 214.71 ± 73 μm, 125.04 ± 60.69 μm, and 890.41 ± 154.76 μm, respectively, with an insignificant correlation between them. The maximum recorded vertical canalicular height in all the cases was far less than the widely reported depth of 2 mm. High-resolution 3D and En face images provided a detailed topography of punctal surface and overview of verticalAbstract : Purpose: To report the features of Fourier domain optical coherence tomography imaging of the normal punctum and vertical canaliculus. Methods: Prospective, interventional series of consecutive healthy and asymptomatic adults, who volunteered for optical coherence tomography imaging, were included in the study. Fourier domain optical coherence tomography images of the punctum and vertical canaliculus along with 3D and En face images were captured using the RTVue scanner with a corneal adaptor module and a wide-angled lens. Maximum punctal diameter, mid-canalicular diameter, and vertical canalicular height were calculated. Statistical analysis was performed using Pearson correlation test, and scatter plot matrices were analyzed. Results: A total of 103 puncta of 52 healthy subjects were studied. Although all the images could depict the punctum and vertical canaliculus and all the desired measurements could be obtained, occasional tear debris within the canaliculus was found to be interfering with the imaging. The mean maximum punctal diameter, mid-canalicular diameter, and vertical canalicular height were recorded as 214.71 ± 73 μm, 125.04 ± 60.69 μm, and 890.41 ± 154.76 μm, respectively, with an insignificant correlation between them. The maximum recorded vertical canalicular height in all the cases was far less than the widely reported depth of 2 mm. High-resolution 3D and En face images provided a detailed topography of punctal surface and overview of vertical canaliculus. Conclusion: Fourier domain optical coherence tomography with 3D and En face imaging is a useful noninvasive modality to image the proximal lacrimal system with consistently reproducible high-resolution images. This is likely to help clinicians in the management of proximal lacrimal disorders. Abstract : Optical Coherence Tomography (OCT) of proximal lacrimal system. … (more)
- Is Part Of:
- Ophthalmic plastic and reconstructive surgery. Volume 32:Issue 3(2016:May/Jun.)
- Journal:
- Ophthalmic plastic and reconstructive surgery
- Issue:
- Volume 32:Issue 3(2016:May/Jun.)
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-05
- Subjects:
- Eye -- Surgery -- Periodicals
Ophthalmic plastic surgery -- Periodicals
Reconstructive Surgical Procedures -- Periodicals
Ophthalmologic Surgical Procedures -- Periodicals
Ophthalmology -- Periodicals
Surgery -- Periodicals
617.70592 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00002341-000000000-00000 ↗
http://www.op-rs.com ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/IOP.0000000000000396 ↗
- Languages:
- English
- ISSNs:
- 0740-9303
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6271.430000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12336.xml