Determining Optic Nerve Cupping Using Optical Coherence Tomography (OCT) Versus a New Electronic Mobile Device. Issue 5 (May 2019)
- Record Type:
- Journal Article
- Title:
- Determining Optic Nerve Cupping Using Optical Coherence Tomography (OCT) Versus a New Electronic Mobile Device. Issue 5 (May 2019)
- Main Title:
- Determining Optic Nerve Cupping Using Optical Coherence Tomography (OCT) Versus a New Electronic Mobile Device
- Authors:
- Sarmento, Andrea G.L.
Sarmento, Adriano
Souza, Luiz L.
Oliveira, Luiz A.
Rios, Marcus F.R.
Domingues, Thiago A.L.
Paula, Jayter S.
Lira, Rodrigo P.C. - Abstract:
- Abstract : Purpose: We present a new device that may aid in glaucoma screening. The vertical cup-to-disc ratio (CDR) obtained from a new electronic mobile device (EMD) was compared with that obtained from a spectral-domain optical coherence tomography. In addition, results from examiner's evaluations were compared with the results mentioned above. Methods: A single-masked study was performed to evaluate the CDR results from 110 eyes from 110 subjects whose ages ranged between 18 and 60 years (39±13 y old), of whom 66 (60%) were female individuals. Vertical CDR was analyzed 5 times with each device in a single visit and evaluated by 3 different ophthalmologists. The Spearman correlation test and Bland-Altman analysis were used to evaluate the correlation and agreement between methods. Results: The CDR average using spectral-domain optical coherence tomography was 0.47±0.04, whereas the CDR average using EMD was 0.42±0.02. The clinical evaluation resulted in an average of 0.34±0.27. The Spearman test showed a strong correlation between vertical CDR obtained with both devices ( r =0.8319; P <0.0001) and between EMD and the examiners ( r =0.7156; P >0.001). Bland-Altman analysis showed good agreement between both devices as well as between EMD and the examiners (95% limits of agreement from −0.20 to 0.10 and from −0.15 to 0.30, respectively). Conclusions: We present a low-cost, reliable EMD that may serve as an alternative to subjectively measuring vertical CDR in face-to-faceAbstract : Purpose: We present a new device that may aid in glaucoma screening. The vertical cup-to-disc ratio (CDR) obtained from a new electronic mobile device (EMD) was compared with that obtained from a spectral-domain optical coherence tomography. In addition, results from examiner's evaluations were compared with the results mentioned above. Methods: A single-masked study was performed to evaluate the CDR results from 110 eyes from 110 subjects whose ages ranged between 18 and 60 years (39±13 y old), of whom 66 (60%) were female individuals. Vertical CDR was analyzed 5 times with each device in a single visit and evaluated by 3 different ophthalmologists. The Spearman correlation test and Bland-Altman analysis were used to evaluate the correlation and agreement between methods. Results: The CDR average using spectral-domain optical coherence tomography was 0.47±0.04, whereas the CDR average using EMD was 0.42±0.02. The clinical evaluation resulted in an average of 0.34±0.27. The Spearman test showed a strong correlation between vertical CDR obtained with both devices ( r =0.8319; P <0.0001) and between EMD and the examiners ( r =0.7156; P >0.001). Bland-Altman analysis showed good agreement between both devices as well as between EMD and the examiners (95% limits of agreement from −0.20 to 0.10 and from −0.15 to 0.30, respectively). Conclusions: We present a low-cost, reliable EMD that may serve as an alternative to subjectively measuring vertical CDR in face-to-face consultations and hence increase the general public's access to glaucoma screening. This may be especially useful for patients who live in remote areas. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 28:Issue 5(2019)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 28:Issue 5(2019)
- Issue Display:
- Volume 28, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 28
- Issue:
- 5
- Issue Sort Value:
- 2019-0028-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-05
- Subjects:
- glaucoma -- cup-to-disc ratio -- optical coherence tomography -- telemedicine
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000001139 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12335.xml