Tissue Thickness Effects on Immunohistochemical Staining Intensity of Markers of Cancer. Issue 5 (May 2019)
- Record Type:
- Journal Article
- Title:
- Tissue Thickness Effects on Immunohistochemical Staining Intensity of Markers of Cancer. Issue 5 (May 2019)
- Main Title:
- Tissue Thickness Effects on Immunohistochemical Staining Intensity of Markers of Cancer
- Authors:
- McCampbell, Adrienne S.
Raghunathan, Varun
Tom-Moy, May
Workman, Richard K.
Haven, Rick
Ben-Dor, Amir
Rasmussen, Ole F.
Jacobsen, Lars
Lindberg, Martin
Yamada, N. Alice
Schembri, Carol - Abstract:
- Abstract : High-quality patient samples are required for reliable immunohistochemistry test outcomes that provide a significant benefit for patient care. Among the preanalytic variables in tissue handling, tissue thickness is thought to be easily controlled; however, whether the thickness of the tissue effects the staining intensity for antibody immunohistochemistry has not been quantitatively demonstrated. To investigate, we cut multiblock tissue sections of tonsil, liver, and kidney at 2, 4, 6, and 8 μm thicknesses. Interferometry measurements of the sectioned paraffin showed a <1 μm variation within a preset microtome thickness. Sections were then immunostained with antibodies targeting different cellular localizations; Ki-67 and BCL6 (nuclear), CD7 (membranous), and cytokeratin (cytoplasmic). A pathologist annotated regions of interest for each marker and performed brightfield and whole-slide visual scoring. Then a pixel-wise processing algorithm determined intensity of each pixel in these regions of interest and binned them into predetermined 0, 1+, 2+, or 3+ intensities. Visual scores from brightfield and whole-slide images were highly correlated to the percentage of pixels in each intensity bin. A stepwise increase was observed in pathologist scores and algorithmically defined percentage of pixels in each bin with increasing thickness demonstrating that changes in preset section thickness impacts staining intensity. The use of tissue thickness outside vendors'Abstract : High-quality patient samples are required for reliable immunohistochemistry test outcomes that provide a significant benefit for patient care. Among the preanalytic variables in tissue handling, tissue thickness is thought to be easily controlled; however, whether the thickness of the tissue effects the staining intensity for antibody immunohistochemistry has not been quantitatively demonstrated. To investigate, we cut multiblock tissue sections of tonsil, liver, and kidney at 2, 4, 6, and 8 μm thicknesses. Interferometry measurements of the sectioned paraffin showed a <1 μm variation within a preset microtome thickness. Sections were then immunostained with antibodies targeting different cellular localizations; Ki-67 and BCL6 (nuclear), CD7 (membranous), and cytokeratin (cytoplasmic). A pathologist annotated regions of interest for each marker and performed brightfield and whole-slide visual scoring. Then a pixel-wise processing algorithm determined intensity of each pixel in these regions of interest and binned them into predetermined 0, 1+, 2+, or 3+ intensities. Visual scores from brightfield and whole-slide images were highly correlated to the percentage of pixels in each intensity bin. A stepwise increase was observed in pathologist scores and algorithmically defined percentage of pixels in each bin with increasing thickness demonstrating that changes in preset section thickness impacts staining intensity. The use of tissue thickness outside vendors' recommendations might change the intensity including the proportion of positive and negative cells and eventually the overall diagnosis outcome. Therefore, we recommend that tissue be consistently cut within the middle of thickness range specified by the assay manufacturer. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Applied immunohistochemistry & molecular morphology. Volume 27:Issue 5(2019)
- Journal:
- Applied immunohistochemistry & molecular morphology
- Issue:
- Volume 27:Issue 5(2019)
- Issue Display:
- Volume 27, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 27
- Issue:
- 5
- Issue Sort Value:
- 2019-0027-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-05
- Subjects:
- tissue thickness -- staining intensity -- Ki-67 -- BCL6 -- CD7 -- CK -- algorithm
Diagnostic immunohistochemistry -- Periodicals
Immunohistochemistry -- Periodicals
Cells -- Morphology -- Periodicals
Molecular diagnosis -- Periodicals
616.079 - Journal URLs:
- http://journals.lww.com/appliedimmunohist/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/PAI.0000000000000593 ↗
- Languages:
- English
- ISSNs:
- 1541-2016
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1573.140000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12309.xml