Performance of LC–MS/MS and immunoassay based 24-h urine free cortisol in the diagnosis of Cushing's syndrome. Issue 190 (June 2019)
- Record Type:
- Journal Article
- Title:
- Performance of LC–MS/MS and immunoassay based 24-h urine free cortisol in the diagnosis of Cushing's syndrome. Issue 190 (June 2019)
- Main Title:
- Performance of LC–MS/MS and immunoassay based 24-h urine free cortisol in the diagnosis of Cushing's syndrome
- Authors:
- Oßwald, Andrea
Wang, Rong
Beuschlein, Felix
Hartmann, Michaela F.
Wudy, Stefan A.
Bidlingmaier, Martin
Zopp, Stephanie
Reincke, Martin
Ritzel, Katrin - Abstract:
- Highlights: Immunoassays overestimate urinary free cortisol (UFC) due to interfering steroid metabolites. UFC measurement with established immunoassays correlate with LC–MS/MS. Measured by ROC AUC, diagnostic accuracy of immunoassays is comparable to LC–MS/MS. Abstract: 24-h urine free cortisol (UFC) is an indicator of integrated cortisol secretion and established screening tool for Cushing's syndrome (CS). Doubts have been raised regarding specificity of immunoassays, and mass spectrometric techniques have been proposed as an alternative. In the present study we compared diagnostic accuracy of UFC measured with LC–MS/MS vs. immunoassay in patient with CS and patients where CS has been excluded. We examined 24-h urine samples from patients with surgically confirmed CS (n = 77; Cushing's disease (n = 44), ectopic CS (n = 5), adrenal CS (n = 28)) and patients in whom Cushing's syndrome was excluded (n = 97) by long-term follow up. UFC was first measured by automated chemiluminescence immunoassays (ADVIA Centaur, Siemens; LIAISON, DiaSorin). Aliquots of all samples were also analyzed by liquid chromatography-tandem mass spectrometry (LC–MS/MS). Statistics: Passing-Bablok Regression, Receiver operating characteristic (ROC) analysis with Youden's index calculation. UFC of CS patients were higher with both immunoassays compared to LC–MS/MS (913 +/- 235 vs. 303 +/- 155 μg/24 h (ADVIA) and 898 +/-216 vs. 399 +/- 196 μg/24 h (LIAISON)). Similarly, UFC were higher with immunoassaysHighlights: Immunoassays overestimate urinary free cortisol (UFC) due to interfering steroid metabolites. UFC measurement with established immunoassays correlate with LC–MS/MS. Measured by ROC AUC, diagnostic accuracy of immunoassays is comparable to LC–MS/MS. Abstract: 24-h urine free cortisol (UFC) is an indicator of integrated cortisol secretion and established screening tool for Cushing's syndrome (CS). Doubts have been raised regarding specificity of immunoassays, and mass spectrometric techniques have been proposed as an alternative. In the present study we compared diagnostic accuracy of UFC measured with LC–MS/MS vs. immunoassay in patient with CS and patients where CS has been excluded. We examined 24-h urine samples from patients with surgically confirmed CS (n = 77; Cushing's disease (n = 44), ectopic CS (n = 5), adrenal CS (n = 28)) and patients in whom Cushing's syndrome was excluded (n = 97) by long-term follow up. UFC was first measured by automated chemiluminescence immunoassays (ADVIA Centaur, Siemens; LIAISON, DiaSorin). Aliquots of all samples were also analyzed by liquid chromatography-tandem mass spectrometry (LC–MS/MS). Statistics: Passing-Bablok Regression, Receiver operating characteristic (ROC) analysis with Youden's index calculation. UFC of CS patients were higher with both immunoassays compared to LC–MS/MS (913 +/- 235 vs. 303 +/- 155 μg/24 h (ADVIA) and 898 +/-216 vs. 399 +/- 196 μg/24 h (LIAISON)). Similarly, UFC were higher with immunoassays than with LC–MS/MS in the control group (223 +/- 10 vs. 23 +/- 2 μg/24 h (ADVIA) and 105 +/- 6 vs. 27 +/- 4 ug/24 h for (LIAISON)). Passing-Bablok regression showed good correlation between LC–MS/MS and ADVIA as well as between LCMS/MS and LIAISON (r = 0.96 and r = 0.99, p < 000.1) but less correlation in controls (r = 0.83 and r = 0.74, respectively, p < 000.1). ROC calculation revealed the highest ROC AUC (0.89) for the LIAISON immunoassay, followed by LC–MS/MS (0.82) and the ADVIA (0.80). In direct comparison, AUCs from LC–MS/MS and immunoassays in the same patient were not statistically different (p < 0, 001). Best cut-off concentration to identify patients with CS was 234 μg/24 h (LIAISON), 51 μg/24 h for LC–MS/MS and 330 μg/24 h (ADVIA Centaur). In summary, UFC values were measured substantially higher by both immunoassays compared to LC–MS/MS. This is most likely due to cross-reactivity from interfering glucocorticoid metabolites. Nevertheless, all three methods correlated well. ROC analysis revealed the highest AUC for one of the immunoassays, although differences between the three methods were not significant. Direct comparison with LC–MS/MS indicates that high diagnostic accuracy can be obtained with suitable immunoassays. … (more)
- Is Part Of:
- Journal of steroid biochemistry and molecular biology. Issue 190(2019)
- Journal:
- Journal of steroid biochemistry and molecular biology
- Issue:
- Issue 190(2019)
- Issue Display:
- Volume 190, Issue 190 (2019)
- Year:
- 2019
- Volume:
- 190
- Issue:
- 190
- Issue Sort Value:
- 2019-0190-0190-0000
- Page Start:
- 193
- Page End:
- 197
- Publication Date:
- 2019-06
- Subjects:
- LC–MS/MS -- Immunoassay -- Urine free cortisol -- Cushing's syndrome
Steroid hormones -- Periodicals
Biochemistry -- Periodicals
Hormones -- Periodicals
Molecular Biology -- Periodicals
Hormones stéroïdes -- Périodiques
Steroid hormones
Periodicals
572.579 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09600760 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jsbmb.2019.04.004 ↗
- Languages:
- English
- ISSNs:
- 0960-0760
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5066.850010
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12294.xml