Effect of low magnetic field on single-diode dosimetry for clinical use. (April 2019)
- Record Type:
- Journal Article
- Title:
- Effect of low magnetic field on single-diode dosimetry for clinical use. (April 2019)
- Main Title:
- Effect of low magnetic field on single-diode dosimetry for clinical use
- Authors:
- Choi, Chang Heon
Park, Jong Min
An, Hyun Joon
Kim, Jung-in - Abstract:
- Highlights: The effect of magnetic field on two QED™ detector was investigated for clinical use. Angular dependence, response on depth, and output factor were evaluated. Black QED on surface requires the correction for directions and magnetic-field. Blue QED does not require correction for clinical use. Abstract: Purpose: To evaluate the effect of a low magnetic field (B-field, 0.35 T) on QED™ for clinical use. Methods: Black and Blue QED were irradiated using tri-Co-60 magnetic resonance image-guided radiation therapy systems with and without the B-field. For both detectors, angular dependence of the beam orientation was evaluated by rotating the gantry and detector in parallel and perpendicular directions to the B-field. Angular dependence between the directions of both QED and B-field was also measured. Response on the depth and output factor of both detectors was investigated for parallel and perpendicular setups, respectively. Results: When Black QED was placed on a surface, detector response decreased by 1.8% and 4.5% for parallel and perpendicular setups, respectively, owing to the B-field. The angular dependence of the beam orientation was not affected by B-field for both detectors. There was a significant angular dependence between Black QED and B-field direction and for the Black QED when the gantry was rotated. Owing to the B-field, the detector response at 90° decreased by 2.4%, response of Black QED on the depth was changed only on the surface, and output factorHighlights: The effect of magnetic field on two QED™ detector was investigated for clinical use. Angular dependence, response on depth, and output factor were evaluated. Black QED on surface requires the correction for directions and magnetic-field. Blue QED does not require correction for clinical use. Abstract: Purpose: To evaluate the effect of a low magnetic field (B-field, 0.35 T) on QED™ for clinical use. Methods: Black and Blue QED were irradiated using tri-Co-60 magnetic resonance image-guided radiation therapy systems with and without the B-field. For both detectors, angular dependence of the beam orientation was evaluated by rotating the gantry and detector in parallel and perpendicular directions to the B-field. Angular dependence between the directions of both QED and B-field was also measured. Response on the depth and output factor of both detectors was investigated for parallel and perpendicular setups, respectively. Results: When Black QED was placed on a surface, detector response decreased by 1.8% and 4.5% for parallel and perpendicular setups, respectively, owing to the B-field. The angular dependence of the beam orientation was not affected by B-field for both detectors. There was a significant angular dependence between Black QED and B-field direction and for the Black QED when the gantry was rotated. Owing to the B-field, the detector response at 90° decreased by 2.4%, response of Black QED on the depth was changed only on the surface, and output factor of Black QED was changed only on the surface. The response of Blue QED was not affected by the B-field for all examined situations. Conclusions: Using Black QED on a surface in the same position as that in the calibration requires some correction to the B-field. Blue QED does not require correction as it is not affected by the B-field. … (more)
- Is Part Of:
- Physica medica. Volume 60(2019)
- Journal:
- Physica medica
- Issue:
- Volume 60(2019)
- Issue Display:
- Volume 60, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 60
- Issue:
- 2019
- Issue Sort Value:
- 2019-0060-2019-0000
- Page Start:
- 132
- Page End:
- 138
- Publication Date:
- 2019-04
- Subjects:
- MR-IGRT -- QED detector -- Diode detector -- In vivo dosimetry
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2019.04.001 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12290.xml