Evaluation of left atrial linear ablation using contiguous and optimized radiofrequency lesions: the ALINE study. Issue Volume 20:Issue FI 3(2018) (8th January 2018)
- Record Type:
- Journal Article
- Title:
- Evaluation of left atrial linear ablation using contiguous and optimized radiofrequency lesions: the ALINE study. Issue Volume 20:Issue FI 3(2018) (8th January 2018)
- Main Title:
- Evaluation of left atrial linear ablation using contiguous and optimized radiofrequency lesions: the ALINE study
- Authors:
- Wolf, Michael
El Haddad, Milad
Fedida, Joël
Taghji, Philippe
Van Beeumen, Katarina
Strisciuglio, Teresa
De Pooter, Jan
Lepièce, Caroline
Vandekerckhove, Yves
Tavernier, René
Duytschaever, Mattias
Knecht, Sébastien - Abstract:
- Abstract: Aims: Achieving block across linear lesions is challenging. We prospectively evaluated radiofrequency (RF) linear ablation at the roof and mitral isthmus (MI) using point-by-point contiguous and optimized RF lesions. Methods and results: Forty-one consecutive patients with symptomatic persistent AF underwent stepwise contact force (CF)-guided catheter ablation during ongoing AF. A single linear set of RF lesions was delivered at the roof and posterior MI according to the 'Atrial LINEar' (ALINE) criteria, i.e. point-by-point RF delivery (up to 35 W) respecting strict criteria of contiguity (inter-lesion distance ≤ 6 mm) and indirect lesion depth assessment (ablation index ≥550). We assessed the incidence of bidirectional block across both lines only after restoration of sinus rhythm. After a median RF time of 7 min [interquartile range (IQR) 5–9], first-pass block across roof lines was observed in 38 of 41 (93%) patients. Final bidirectional roof block was achieved in 40 of 41 (98%) patients. First-pass block was observed in 8 of 35 (23%) MI lines, after a median RF time of 8 min (IQR 7–12). Additional endo- and epicardial (54% of patients) RF applications resulted in final bidirectional MI block in 28 of 35 (80%) patients. During a median follow-up of 396 (IQR 310–442) days, 12 patients underwent repeat procedures, with conduction recovery in 4 of 12 and 5 of 10 previously blocked roof lines and MI lines, respectively. No complications occurred. Conclusion:Abstract: Aims: Achieving block across linear lesions is challenging. We prospectively evaluated radiofrequency (RF) linear ablation at the roof and mitral isthmus (MI) using point-by-point contiguous and optimized RF lesions. Methods and results: Forty-one consecutive patients with symptomatic persistent AF underwent stepwise contact force (CF)-guided catheter ablation during ongoing AF. A single linear set of RF lesions was delivered at the roof and posterior MI according to the 'Atrial LINEar' (ALINE) criteria, i.e. point-by-point RF delivery (up to 35 W) respecting strict criteria of contiguity (inter-lesion distance ≤ 6 mm) and indirect lesion depth assessment (ablation index ≥550). We assessed the incidence of bidirectional block across both lines only after restoration of sinus rhythm. After a median RF time of 7 min [interquartile range (IQR) 5–9], first-pass block across roof lines was observed in 38 of 41 (93%) patients. Final bidirectional roof block was achieved in 40 of 41 (98%) patients. First-pass block was observed in 8 of 35 (23%) MI lines, after a median RF time of 8 min (IQR 7–12). Additional endo- and epicardial (54% of patients) RF applications resulted in final bidirectional MI block in 28 of 35 (80%) patients. During a median follow-up of 396 (IQR 310–442) days, 12 patients underwent repeat procedures, with conduction recovery in 4 of 12 and 5 of 10 previously blocked roof lines and MI lines, respectively. No complications occurred. Conclusion: Anatomical linear ablation using contiguous and optimized RF lesions results in a high rate of first-pass block at the roof but not at the MI. Due to its complex 3D architecture, the MI frequently requires additional endo- and epicardial RF lesions to be blocked. … (more)
- Is Part Of:
- Europace. Volume 20:Issue FI 3(2018)
- Journal:
- Europace
- Issue:
- Volume 20:Issue FI 3(2018)
- Issue Display:
- Volume 20, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 20
- Issue:
- 3
- Issue Sort Value:
- 2018-0020-0003-0000
- Page Start:
- f401
- Page End:
- f409
- Publication Date:
- 2018-01-08
- Subjects:
- Atrial fibrillation -- Catheter ablation -- Linear ablation -- Roof line -- Mitral isthmus line -- Contact force -- Ablation index
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/eux350 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12280.xml