Single freeze per vein strategy with the second-generation cryoballoon for atrial fibrillation: a propensity score-matched study between 180- and 240-s application time in a large cohort of patients. Issue Volume 20:Issue FI 3(2018) (2nd November 2017)
- Record Type:
- Journal Article
- Title:
- Single freeze per vein strategy with the second-generation cryoballoon for atrial fibrillation: a propensity score-matched study between 180- and 240-s application time in a large cohort of patients. Issue Volume 20:Issue FI 3(2018) (2nd November 2017)
- Main Title:
- Single freeze per vein strategy with the second-generation cryoballoon for atrial fibrillation: a propensity score-matched study between 180- and 240-s application time in a large cohort of patients
- Authors:
- De Regibus, Valentina
Abugattas, Juan-Pablo
Iacopino, Saverio
Mugnai, Giacomo
Storti, Cesare
Conte, Giulio
Auricchio, Angelo
Ströker, Erwin
Coutiño, Hugo-Enrique
Takarada, Ken
Salghetti, Francesca
Lusoc, Ian
Capulzini, Lucio
Brugada, Pedro
de Asmundis, Carlo
Chierchia, Gian-Battista - Abstract:
- Abstract: Aims: The single-freeze strategy using the second-generation cryoballoon (CB-A, Arctic Front Advance, Medtronic, Minneapolis, MN, USA) has been reported to be as effective as the recommended double-freeze approach in several single-centre studies. In this retrospective, international, multicentre study, we compare the 3-min single-freeze strategy with the 4-min single-freeze strategy. Methods and results: Four hundred and thirty-two patients having undergone pulmonary vein isolation (PVI) by means of CB-A using a single-freeze strategy were considered for this analysis. A cohort of patients who were treated with a 3-min strategy (Group 1) was compared with a propensity score-matched cohort of patients who underwent a 4-min strategy (Group 2). Pulmonary vein isolation was successfully achieved in all the veins using the 28-mm CB-A. The procedural and fluoroscopy times were lower in Group 1 (67.8 ± 17 vs. 73.8 ± 26.3, P < 0.05; 14.9 ± 7.8 vs. 24.2 ± 10.6 min, P < 0.05). The most frequent complication was PNP, with no difference between the two groups ( P = 0.67). After a mean follow-up of 13 ± 8 months, taking into consideration a blanking period of 3 months, 85.6% of patients in Group 1 and 87% of patients in Group 2 were free from arrhythmia recurrence at final follow-up ( P = 0.67). Conclusion: There is no difference in acute success, rate of complications, and freedom from atrial fibrillation recurrences during the follow-up between 3-min and 4-min per veinAbstract: Aims: The single-freeze strategy using the second-generation cryoballoon (CB-A, Arctic Front Advance, Medtronic, Minneapolis, MN, USA) has been reported to be as effective as the recommended double-freeze approach in several single-centre studies. In this retrospective, international, multicentre study, we compare the 3-min single-freeze strategy with the 4-min single-freeze strategy. Methods and results: Four hundred and thirty-two patients having undergone pulmonary vein isolation (PVI) by means of CB-A using a single-freeze strategy were considered for this analysis. A cohort of patients who were treated with a 3-min strategy (Group 1) was compared with a propensity score-matched cohort of patients who underwent a 4-min strategy (Group 2). Pulmonary vein isolation was successfully achieved in all the veins using the 28-mm CB-A. The procedural and fluoroscopy times were lower in Group 1 (67.8 ± 17 vs. 73.8 ± 26.3, P < 0.05; 14.9 ± 7.8 vs. 24.2 ± 10.6 min, P < 0.05). The most frequent complication was PNP, with no difference between the two groups ( P = 0.67). After a mean follow-up of 13 ± 8 months, taking into consideration a blanking period of 3 months, 85.6% of patients in Group 1 and 87% of patients in Group 2 were free from arrhythmia recurrence at final follow-up ( P = 0.67). Conclusion: There is no difference in acute success, rate of complications, and freedom from atrial fibrillation recurrences during the follow-up between 3-min and 4-min per vein freeze strategies. The procedural and fluoroscopy times were significantly shorter in 3-min per vein strategy. … (more)
- Is Part Of:
- Europace. Volume 20:Issue FI 3(2018)
- Journal:
- Europace
- Issue:
- Volume 20:Issue FI 3(2018)
- Issue Display:
- Volume 20, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 20
- Issue:
- 3
- Issue Sort Value:
- 2018-0020-0003-0000
- Page Start:
- f377
- Page End:
- f383
- Publication Date:
- 2017-11-02
- Subjects:
- Atrial fibrillation -- Cryoballoon -- Pulmonary vein isolation -- Single freeze
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/eux279 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12280.xml