Safety and long-term effectiveness of paroxysmal atrial fibrillation ablation with a contact force-sensing catheter: real-world experience from a prospective, multicentre observational cohort registry. Issue Volume 20:Issue FI 3(2018) (4th January 2018)
- Record Type:
- Journal Article
- Title:
- Safety and long-term effectiveness of paroxysmal atrial fibrillation ablation with a contact force-sensing catheter: real-world experience from a prospective, multicentre observational cohort registry. Issue Volume 20:Issue FI 3(2018) (4th January 2018)
- Main Title:
- Safety and long-term effectiveness of paroxysmal atrial fibrillation ablation with a contact force-sensing catheter: real-world experience from a prospective, multicentre observational cohort registry
- Authors:
- De Potter, Tom
Van Herendael, Hugo
Balasubramaniam, Richard
Wright, Matthew
Agarwal, Sharad C
Sanders, Prashanthan
Khaykin, Yaariv
Latcu, Decebal-Gabriel
Maury, Philippe
Pani, Antonio
Hayes, John
Kalman, Jonathan
Nery, Pablo
Duncan, Edward - Abstract:
- Abstract: Aims: Real-time contact force (CF)-sensing radiofrequency ablation catheter for treatment of paroxysmal atrial fibrillation (PAF) allows optimization of electrode–tissue contact, which correlates with long-term success. This prospective, multicentre observational registry assessed the real-world clinical effectiveness of a CF-sensing catheter for ablation of drug-refractory PAF. Methods and results: Patients were followed-up at 3, 6, and 12 months after ablation. Outcome measures included isolation of targeted pulmonary veins (PVs) confirmed by entrance block (acute success), patient-reported freedom from symptomatic atrial fibrillation (AF) at 12 months (long-term effectiveness), Atrial Fibrillation Effect on Quality-of-life scores at 6 and 12 months, and incidence of predefined procedural complications. The registry enrolled 261 PAF patients (mean age 58.8 ± 11.3 years; 70.7% men; 91.7% Caucasian). Acute PV isolation was reported in 98.8% of patients [95% confidence interval (CI): 96.4–99.7%], and 12-month success for freedom from symptomatic AF was 75.7% (95% CI: 69.7–80.7%). Average CF for the evaluable cohort was 16.4 ± 3.9 g. There was a significant correlation between long-term effectiveness and stability of CF use [percentage of time CF was within investigator-selected working range; odds ratio (95% Wald CI), 1.0 (1.00–1.1); P = 0.030]. Average CF did not correlate with 12-month success. Clinically meaningful quality of life (QoL) improvements wereAbstract: Aims: Real-time contact force (CF)-sensing radiofrequency ablation catheter for treatment of paroxysmal atrial fibrillation (PAF) allows optimization of electrode–tissue contact, which correlates with long-term success. This prospective, multicentre observational registry assessed the real-world clinical effectiveness of a CF-sensing catheter for ablation of drug-refractory PAF. Methods and results: Patients were followed-up at 3, 6, and 12 months after ablation. Outcome measures included isolation of targeted pulmonary veins (PVs) confirmed by entrance block (acute success), patient-reported freedom from symptomatic atrial fibrillation (AF) at 12 months (long-term effectiveness), Atrial Fibrillation Effect on Quality-of-life scores at 6 and 12 months, and incidence of predefined procedural complications. The registry enrolled 261 PAF patients (mean age 58.8 ± 11.3 years; 70.7% men; 91.7% Caucasian). Acute PV isolation was reported in 98.8% of patients [95% confidence interval (CI): 96.4–99.7%], and 12-month success for freedom from symptomatic AF was 75.7% (95% CI: 69.7–80.7%). Average CF for the evaluable cohort was 16.4 ± 3.9 g. There was a significant correlation between long-term effectiveness and stability of CF use [percentage of time CF was within investigator-selected working range; odds ratio (95% Wald CI), 1.0 (1.00–1.1); P = 0.030]. Average CF did not correlate with 12-month success. Clinically meaningful quality of life (QoL) improvements were observed at 6 and 12 months. Primary adverse events occurred in 2.7% patients. Conclusion: This observational registry showed that PAF ablation with a CF-sensing catheter had high acute success rates, favourable 12-month outcomes, and a good safety profile. Patients' QoL improved significantly. Long-term effectiveness significantly correlated with stable CF with adequate catheter–tissue contact (NCT01677052). … (more)
- Is Part Of:
- Europace. Volume 20:Issue FI 3(2018)
- Journal:
- Europace
- Issue:
- Volume 20:Issue FI 3(2018)
- Issue Display:
- Volume 20, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 20
- Issue:
- 3
- Issue Sort Value:
- 2018-0020-0003-0000
- Page Start:
- f410
- Page End:
- f418
- Publication Date:
- 2018-01-04
- Subjects:
- Contact force -- Pulmonary vein isolation -- Paroxysmal atrial fibrillation -- Outcome -- Registry
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/eux290 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12280.xml