Computational fluid dynamics study to reduce heat losses at the receiver of a solar tower plant. (15th September 2019)
- Record Type:
- Journal Article
- Title:
- Computational fluid dynamics study to reduce heat losses at the receiver of a solar tower plant. (15th September 2019)
- Main Title:
- Computational fluid dynamics study to reduce heat losses at the receiver of a solar tower plant
- Authors:
- Schmitt, Alexander
Dinter, Frank
Reichel, Christoph - Abstract:
- Highlights: Dome construction on top of a solar tower reduces heat losses. CFD simulations indicate the ability to reduce convective and even more radiative heat losses. Reducing convective losses at very high wind loads needs more elaborate design. Abstract: Today, renewable energy systems are developing rapidly and are reaching economic competitiveness with conventional power plants. Due to their ability to efficiently integrate energy storage systems, concentrated solar power plants are ascribed a high potential for energy generation. Typically, the usage of molten salt as heat transfer fluid in the receiver reaches thermal efficiencies of 80–88% (de Meyer et al., 2016. Thermal Resistance Model for CSP Central Receivers ). Placing the dome on top of the tower may be a measure in order to reduce the heat losses at the receiver. In the presented work, a computational fluid dynamics 1 (CFD) study with the commercial simulation package STAR-CCM+ 2 (Simulation of Turbulent flow in Arbitrary Regions - Computational Continuum Mechanics, C++ based) was executed to investigate the impact of placing the dome geometry on top of the solar tower. Mainly the potential to reduce convective and radiative heat losses at the molten salt receiver at various wind loads was analyzed. The respective Crescent Dunes plant in Las Vegas (Nevada) with an electrical net power of 110 MW was chosen as reference for generating the required input data for the simulations. Overall six simulation modelsHighlights: Dome construction on top of a solar tower reduces heat losses. CFD simulations indicate the ability to reduce convective and even more radiative heat losses. Reducing convective losses at very high wind loads needs more elaborate design. Abstract: Today, renewable energy systems are developing rapidly and are reaching economic competitiveness with conventional power plants. Due to their ability to efficiently integrate energy storage systems, concentrated solar power plants are ascribed a high potential for energy generation. Typically, the usage of molten salt as heat transfer fluid in the receiver reaches thermal efficiencies of 80–88% (de Meyer et al., 2016. Thermal Resistance Model for CSP Central Receivers ). Placing the dome on top of the tower may be a measure in order to reduce the heat losses at the receiver. In the presented work, a computational fluid dynamics 1 (CFD) study with the commercial simulation package STAR-CCM+ 2 (Simulation of Turbulent flow in Arbitrary Regions - Computational Continuum Mechanics, C++ based) was executed to investigate the impact of placing the dome geometry on top of the solar tower. Mainly the potential to reduce convective and radiative heat losses at the molten salt receiver at various wind loads was analyzed. The respective Crescent Dunes plant in Las Vegas (Nevada) with an electrical net power of 110 MW was chosen as reference for generating the required input data for the simulations. Overall six simulation models were set up: two geometries, one with and one without a dome, and each of the geometries with three variable wind loads (Beaufort Number (BN 3 ) 2, 4 and 6). In the main part, the radiative and convective heat losses at the receiver were analyzed for the BN 4 and afterwards compared to the results with the models BN 2 and BN 6. The construction of the dome reduced the heat losses at the receiver by 1.92 MW (BN 4) with the radiation energy savings (1.32 MW) being higher than the reduction of convective losses (0.60 MW). Furthermore, the reduced heat losses are 1.79 MW for BN 2 and only 0.43 MW for BN 6. Besides in the last case, the convective losses actually rise and the function of the dome turns out as counterproductive. Nevertheless, the results can be fundamental for further research projects as the dependence of the heat losses on variations of the dome form and the installation of components to disturb or eliminate a convective heat flow at the receiver can be essential to future studies. However, each concept must be seen in terms of economic and technical feasibility. … (more)
- Is Part Of:
- Solar energy. Volume 190(2019)
- Journal:
- Solar energy
- Issue:
- Volume 190(2019)
- Issue Display:
- Volume 190, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 190
- Issue:
- 2019
- Issue Sort Value:
- 2019-0190-2019-0000
- Page Start:
- 286
- Page End:
- 300
- Publication Date:
- 2019-09-15
- Subjects:
- Computational fluid dynamics -- Concentrating solar power plants -- High temperature processes -- Central receiver -- Crescent dunes solar energy facility -- Convective and radiative heat losses
Solar energy -- Periodicals
Solar engines -- Periodicals
621.47 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0038092X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.solener.2019.07.079 ↗
- Languages:
- English
- ISSNs:
- 0038-092X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8327.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12272.xml