Early and long-term outcomes after manual and remote magnetic navigation-guided catheter ablation for ventricular tachycardia. (1st May 2018)
- Record Type:
- Journal Article
- Title:
- Early and long-term outcomes after manual and remote magnetic navigation-guided catheter ablation for ventricular tachycardia. (1st May 2018)
- Main Title:
- Early and long-term outcomes after manual and remote magnetic navigation-guided catheter ablation for ventricular tachycardia
- Authors:
- Qian, Pierre
De Silva, Kasun
Kumar, Saurabh
Nadri, Fazlur
Samanta, Rahul
Bhaskaran, Abhishek
Ross, David
Sivagangabalan, Gopal
Cooper, Mark
Kizana, Eddy
Davis, Lloyd
Denniss, Alan Robert
Thiagalingam, Aravinda
Thomas, Stuart
Kovoor, Pramesh - Abstract:
- Abstract: Aims: Remote magnetic navigation (RMN) is a safe and effective means of performing ventricular tachycardia (VT) ablation. It may have advantages over manual catheter ablation due to ease of manoeuvrability and catheter stability. We sought to compare the safety and efficacy of RMN vs. manual VT ablation. Methods and results: Retrospective study of procedural outcomes of 139 consecutive VT ablation procedures (69 RMN, 70 manual ablation) in 113 patients between 2009 and 2015 was performed. Remote magnetic navigation was associated with overall higher acute procedural success (80% vs. 60%, P = 0.01), with a trend to fewer major complications (3% vs. 9% P = 0.09). Seventy-nine patients were followed up for a median of 17.0 [interquartile range (IQR) 3.0–41.0] months for the RMN group and 15.5 (IQR 6.5–30.0) months for manual ablation group. In the ischaemic cardiomyopathy subgroup, RMN was associated with longer survival from the composite endpoint of VT recurrence leading to defibrillator shock, re-hospitalization or repeat catheter ablation and all-cause mortality; single-procedure adjusted hazard ratio (HR) 0.240 (95% CI 0.070–0.821) P = 0.023, multi-procedure HR 0.170 (95% CI 0.046–0.632) P = 0.002. In patients with implanted defibrillators, multi-procedure VT-free survival was superior with RMN, HR 0.199 (95% CI 0.060–0.657) P = 0.003. Conclusion: Remote magnetic navigation may improve clinical outcomes after catheter ablation of VT in patients withAbstract: Aims: Remote magnetic navigation (RMN) is a safe and effective means of performing ventricular tachycardia (VT) ablation. It may have advantages over manual catheter ablation due to ease of manoeuvrability and catheter stability. We sought to compare the safety and efficacy of RMN vs. manual VT ablation. Methods and results: Retrospective study of procedural outcomes of 139 consecutive VT ablation procedures (69 RMN, 70 manual ablation) in 113 patients between 2009 and 2015 was performed. Remote magnetic navigation was associated with overall higher acute procedural success (80% vs. 60%, P = 0.01), with a trend to fewer major complications (3% vs. 9% P = 0.09). Seventy-nine patients were followed up for a median of 17.0 [interquartile range (IQR) 3.0–41.0] months for the RMN group and 15.5 (IQR 6.5–30.0) months for manual ablation group. In the ischaemic cardiomyopathy subgroup, RMN was associated with longer survival from the composite endpoint of VT recurrence leading to defibrillator shock, re-hospitalization or repeat catheter ablation and all-cause mortality; single-procedure adjusted hazard ratio (HR) 0.240 (95% CI 0.070–0.821) P = 0.023, multi-procedure HR 0.170 (95% CI 0.046–0.632) P = 0.002. In patients with implanted defibrillators, multi-procedure VT-free survival was superior with RMN, HR 0.199 (95% CI 0.060–0.657) P = 0.003. Conclusion: Remote magnetic navigation may improve clinical outcomes after catheter ablation of VT in patients with ischaemic cardiomyopathy. Further prospective clinical studies are required to confirm these findings. … (more)
- Is Part Of:
- Europace. Volume 20(2018)Supplement 2
- Journal:
- Europace
- Issue:
- Volume 20(2018)Supplement 2
- Issue Display:
- Volume 20, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 20
- Issue:
- 2
- Issue Sort Value:
- 2018-0020-0002-0000
- Page Start:
- ii11
- Page End:
- ii21
- Publication Date:
- 2018-05-01
- Subjects:
- Remote magnetic navigation -- Ventricular tachycardia -- Catheter ablation -- Ischaemic cardiomyopathy
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euy057 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12266.xml