Current management and clinical outcomes for catheter ablation of atrioventricular nodal re-entrant tachycardia. Issue 4 (24th May 2017)
- Record Type:
- Journal Article
- Title:
- Current management and clinical outcomes for catheter ablation of atrioventricular nodal re-entrant tachycardia. Issue 4 (24th May 2017)
- Main Title:
- Current management and clinical outcomes for catheter ablation of atrioventricular nodal re-entrant tachycardia
- Authors:
- Chrispin, Jonathan
Misra, Satish
Marine, Joseph E
Rickard, John
Barth, Andreas
Kolandaivelu, Aravindan
Ashikaga, Hiroshi
Tandri, Harikrishna
Spragg, David D
Crosson, Jane
Berger, Ronald D
Tomaselli, Gordon
Calkins, Hugh
Sinha, Sunil K - Abstract:
- Abstract: Aims: Historical studies of ablation of atrioventricular nodal re-entrant tachycardia (AVNRT) have shown high long-term success rates and low complication rates. The potential impact of several recent practice trends has not been described. This study aims to characterize recent clinical practice trends in AVNRT ablation and their associated success rates and complications. Methods and results: Patients undergoing initial ablation of AVNRT between 1 July 2005 and 30 June 2015 were included in this study. Patient demographics and procedural data were abstracted from procedure reports. Follow-up data, including AVNRT recurrence and complications, was evaluated through electronic medical record review. In total, 877 patients underwent catheter ablation for AVNRT. By the last recorded year, three-dimension (3D) electroanatomical mapping (EAM) was used in 36.2%, 43.2% included anaesthesia, and 23.1% utilized irrigated catheters. Long-term procedural success was 95.5%. The use of anaesthesia, 3D EAM, and irrigated ablation catheters were not associated with differences in success. The presence of an atrial 'echo' or 'AH' jump at the end of an acutely successful procedure was not associated with long-term recurrence ( P = 0.18, P = 0.15, respectively). Complications, including AV block requiring a pacemaker (0.4%), were uncommon. Conclusion: In a large, contemporary cohort, catheter ablation for AVNRT remains highly successful with low complications rates. The increasedAbstract: Aims: Historical studies of ablation of atrioventricular nodal re-entrant tachycardia (AVNRT) have shown high long-term success rates and low complication rates. The potential impact of several recent practice trends has not been described. This study aims to characterize recent clinical practice trends in AVNRT ablation and their associated success rates and complications. Methods and results: Patients undergoing initial ablation of AVNRT between 1 July 2005 and 30 June 2015 were included in this study. Patient demographics and procedural data were abstracted from procedure reports. Follow-up data, including AVNRT recurrence and complications, was evaluated through electronic medical record review. In total, 877 patients underwent catheter ablation for AVNRT. By the last recorded year, three-dimension (3D) electroanatomical mapping (EAM) was used in 36.2%, 43.2% included anaesthesia, and 23.1% utilized irrigated catheters. Long-term procedural success was 95.5%. The use of anaesthesia, 3D EAM, and irrigated ablation catheters were not associated with differences in success. The presence of an atrial 'echo' or 'AH' jump at the end of an acutely successful procedure was not associated with long-term recurrence ( P = 0.18, P = 0.15, respectively). Complications, including AV block requiring a pacemaker (0.4%), were uncommon. Conclusion: In a large, contemporary cohort, catheter ablation for AVNRT remains highly successful with low complications rates. The increased use of anaesthesia as well as modern mapping and ablation tools were not associated with changes in clinical outcomes. Further prospective evaluation of such contemporary practices is warranted given the lack of evidence to support their escalating use. … (more)
- Is Part Of:
- Europace. Volume 20:Issue 4(2018)
- Journal:
- Europace
- Issue:
- Volume 20:Issue 4(2018)
- Issue Display:
- Volume 20, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 20
- Issue:
- 4
- Issue Sort Value:
- 2018-0020-0004-0000
- Page Start:
- e51
- Page End:
- e59
- Publication Date:
- 2017-05-24
- Subjects:
- Atrioventricular nodal re-entrant tachycardia -- Catheter ablation -- Long-term success -- Complications -- Dual AV nodal physiology
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/eux110 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12244.xml