Multielectrode vs. point-by-point mapping for ventricular tachycardia substrate ablation: a randomized study. Issue 3 (9th January 2017)
- Record Type:
- Journal Article
- Title:
- Multielectrode vs. point-by-point mapping for ventricular tachycardia substrate ablation: a randomized study. Issue 3 (9th January 2017)
- Main Title:
- Multielectrode vs. point-by-point mapping for ventricular tachycardia substrate ablation: a randomized study
- Authors:
- Acosta, Juan
Penela, Diego
Andreu, David
Cabrera, Mario
Carlosena, Alicia
Vassanelli, Francesca
Alarcón, Francisco
Soto-Iglesias, David
Korshunov, Viatcheslav
Borras, Roger
Linhart, Markus
Martínez, Mikel
Fernández-Armenta, Juan
Mont, Lluis
Berruezo, Antonio - Abstract:
- Abstract: Aims: Ventricular tachycardia (VT) substrate ablation is based on detailed electroanatomical maps (EAM). This study analyses whether high-density multielectrode mapping (MEM) is superior to conventional point-by-point mapping (PPM) in guiding VT substrate ablation procedures. Methods and results: This was a randomized controlled study (NCT02083016). Twenty consecutive ischemic patients undergoing VT substrate ablation were randomized to either group A [ n = 10; substrate mapping performed first by PPM (Navistar) and secondly by MEM (PentaRay) ablation guided by PPM] or group B [ n = 10; substrate mapping performed first by MEM and second by PPM ablation guided by MEM]. Ablation was performed according to the scar-dechanneling technique. Late potential (LP) pairs were defined as a Navistar-LP and a PentaRay-LP located within a three-dimensional distance of ≤ 3 mm. Data obtained from EAM, procedure time, radiofrequency time, and post-ablation VT inducibility were compared between groups. Larger bipolar scar areas were obtained with MEM (55.7±31.7 vs. 50.5±26.6 cm 2 ; P = 0.017). Substrate mapping time was similar with MEM (19.7±7.9 minutes) and PPM (25±9.2 minutes); P = 0.222. No differences were observed in the number of LPs identified within the scar by MEM vs. PPM (73±50 vs. 76±52 LPs per patient, respectively; P = 0.965). A total of 1104 LP pairs were analysed. Using PentaRay, far-field/LP ratio was significantly lower (0.58±0.4 vs. 1.64±1.1; P = 0.01) andAbstract: Aims: Ventricular tachycardia (VT) substrate ablation is based on detailed electroanatomical maps (EAM). This study analyses whether high-density multielectrode mapping (MEM) is superior to conventional point-by-point mapping (PPM) in guiding VT substrate ablation procedures. Methods and results: This was a randomized controlled study (NCT02083016). Twenty consecutive ischemic patients undergoing VT substrate ablation were randomized to either group A [ n = 10; substrate mapping performed first by PPM (Navistar) and secondly by MEM (PentaRay) ablation guided by PPM] or group B [ n = 10; substrate mapping performed first by MEM and second by PPM ablation guided by MEM]. Ablation was performed according to the scar-dechanneling technique. Late potential (LP) pairs were defined as a Navistar-LP and a PentaRay-LP located within a three-dimensional distance of ≤ 3 mm. Data obtained from EAM, procedure time, radiofrequency time, and post-ablation VT inducibility were compared between groups. Larger bipolar scar areas were obtained with MEM (55.7±31.7 vs. 50.5±26.6 cm 2 ; P = 0.017). Substrate mapping time was similar with MEM (19.7±7.9 minutes) and PPM (25±9.2 minutes); P = 0.222. No differences were observed in the number of LPs identified within the scar by MEM vs. PPM (73±50 vs. 76±52 LPs per patient, respectively; P = 0.965). A total of 1104 LP pairs were analysed. Using PentaRay, far-field/LP ratio was significantly lower (0.58±0.4 vs. 1.64±1.1; P = 0.01) and radiofrequency time was shorter [median (interquartile range) 12 (7–20) vs. 22 (17–33) minutes; P = 0.023]. No differences were observed in VT inducibility after procedure. Conclusion: MEM with PentaRay catheter provided better discrimination of LPs due to a lower sensitivity for far-field signals. Ablation guided by MEM was associated with a shorter radiofrequency time. … (more)
- Is Part Of:
- Europace. Volume 20:Issue 3(2018)
- Journal:
- Europace
- Issue:
- Volume 20:Issue 3(2018)
- Issue Display:
- Volume 20, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 20
- Issue:
- 3
- Issue Sort Value:
- 2018-0020-0003-0000
- Page Start:
- 512
- Page End:
- 519
- Publication Date:
- 2017-01-09
- Subjects:
- Multielectrode mapping -- PentaRay -- Ventricular tachycardia -- Substrate ablation
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euw406 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12248.xml