Patients upgraded to cardiac resynchronization therapy due to pacing-induced cardiomyopathy are at low risk of life-threatening ventricular arrhythmias: a long-term cause-of-death analysis. Issue 1 (22nd December 2016)
- Record Type:
- Journal Article
- Title:
- Patients upgraded to cardiac resynchronization therapy due to pacing-induced cardiomyopathy are at low risk of life-threatening ventricular arrhythmias: a long-term cause-of-death analysis. Issue 1 (22nd December 2016)
- Main Title:
- Patients upgraded to cardiac resynchronization therapy due to pacing-induced cardiomyopathy are at low risk of life-threatening ventricular arrhythmias: a long-term cause-of-death analysis
- Authors:
- Barra, Sergio
Duehmke, Rudolf
Providencia, Rui
Marijon, Eloi
Boveda, Serge
Virdee, Munmohan
Heck, Patrick
Fynn, Simon
Begley, David
Grace, Andrew
Agarwal, Sharad - Abstract:
- Abstract: Aims: Upgrade to cardiac resynchronization therapy (CRT) should be offered to patients who have developed pacing-induced cardiomyopathy with conventional right ventricular pacing. The extent to which these patients would also benefit from defibrillator back-up at the time of CRT upgrade is, however, unknown. Methods and results: Retrospective observational cohort study of 199 patients with pacing-induced cardiomyopathy and no history of sustained ventricular arrhythmia, including 104 upgraded to CRT-Pacemaker (CRT-P) and 95 upgraded to CRT-Defibrillator (CRT-D). The incidence of ventricular arrhythmias and the risk of sudden arrhythmic death obtained through a cause-of-death analysis based on clinical data and necropsy results were assessed and compared between the two groups. During a mean follow-up of 66 ± 24 months, 40 (38.5%) CRT-P patients died: three from primary arrhythmic death, while the remaining died of different causes (especially progressive heart failure), giving an incidence of 6.2 sudden arrhythmic deaths per 1000 patient-years. No episode of sustained VT was observed in the study group. There were no sudden arrhythmic deaths in the CRT-D group during a shorter follow-up, but the small and non-significant difference in all-cause mortality between CRT-Pacemaker (CRT-P) and CRT-D groups was mostly accounted for by an increase in non-sudden death. Women upgraded to CRT were at particularly low risk of all-cause mortality compared with men (HR 0.232, PAbstract: Aims: Upgrade to cardiac resynchronization therapy (CRT) should be offered to patients who have developed pacing-induced cardiomyopathy with conventional right ventricular pacing. The extent to which these patients would also benefit from defibrillator back-up at the time of CRT upgrade is, however, unknown. Methods and results: Retrospective observational cohort study of 199 patients with pacing-induced cardiomyopathy and no history of sustained ventricular arrhythmia, including 104 upgraded to CRT-Pacemaker (CRT-P) and 95 upgraded to CRT-Defibrillator (CRT-D). The incidence of ventricular arrhythmias and the risk of sudden arrhythmic death obtained through a cause-of-death analysis based on clinical data and necropsy results were assessed and compared between the two groups. During a mean follow-up of 66 ± 24 months, 40 (38.5%) CRT-P patients died: three from primary arrhythmic death, while the remaining died of different causes (especially progressive heart failure), giving an incidence of 6.2 sudden arrhythmic deaths per 1000 patient-years. No episode of sustained VT was observed in the study group. There were no sudden arrhythmic deaths in the CRT-D group during a shorter follow-up, but the small and non-significant difference in all-cause mortality between CRT-Pacemaker (CRT-P) and CRT-D groups was mostly accounted for by an increase in non-sudden death. Women upgraded to CRT were at particularly low risk of all-cause mortality compared with men (HR 0.232, P = 0.048). Conclusion: Our findings suggest that patients who develop pacing-induced cardiomyopathy and are upgraded to CRT may not derive any significant benefit from the addition of the defibrillator in the absence of a history of ventricular arrhythmias. … (more)
- Is Part Of:
- Europace. Volume 20:Issue 1(2018)
- Journal:
- Europace
- Issue:
- Volume 20:Issue 1(2018)
- Issue Display:
- Volume 20, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 20
- Issue:
- 1
- Issue Sort Value:
- 2018-0020-0001-0000
- Page Start:
- 89
- Page End:
- 96
- Publication Date:
- 2016-12-22
- Subjects:
- Cardiac resynchronization therapy -- Pacemaker -- Implantable cardioverter-defibrillator -- Ventricular arrhythmias -- Cause of death -- Sudden arrhythmic death
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euw321 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12242.xml