Prosthesis depth and conduction disturbances after last generation balloon-expandable transcatheter aortic valve implantation. Issue 1 (6th October 2016)
- Record Type:
- Journal Article
- Title:
- Prosthesis depth and conduction disturbances after last generation balloon-expandable transcatheter aortic valve implantation. Issue 1 (6th October 2016)
- Main Title:
- Prosthesis depth and conduction disturbances after last generation balloon-expandable transcatheter aortic valve implantation
- Authors:
- Iacovelli, Fortunato
Pignatelli, Antonio
Giugliano, Giuseppe
Stabile, Eugenio
Cicala, Mariangela
Salemme, Luigi
Cioppa, Angelo
Popusoi, Grigore
Pucciarelli, Armando
Verdoliva, Sebastiano
Bortone, Alessandro Santo
Losi, Maria-Angela
Coscioni, Enrico
Esposito, Giovanni
Contegiacomo, Gaetano
Tesorio, Tullio - Abstract:
- Abstract: Aims: Preliminary data on Sapien 3 valve (S3-THV) use for transcatheter aortic valve implantation have shown an increased permanent pacemaker implantation (PPMI) rate with respect to Sapien XT valve. Aim of this study was to investigate the role of S3-THV position in the left ventricular outflow tract (LVOT) on electrocardiographic changes suggestive of atrioventricular (ΔPR) and/or intraventricular (ΔQRS) conduction abnormalities and 30 days PPMI rate. Methods and results: Eighty-six consecutive patients treated with S3-THV were included in the study. All patients underwent clinical and electrocardiogram evaluation. Left ventricular outflow tract prosthesis depth was assessed by fluoroscopy and expressed quantitatively (mm) and as aorto-ventricular ratio (AVR). Eight patients (9.3%) needed PPMI at 30 days. A low AVR (≤60/40) predicted PPMI (OR = 6.09, 95% CI 1.19–31.01, P = 0.030) and resulted into higher PPMI rate, compared with higher AVR (30.0 vs. 6.6%, P = 0.017). For each millimetre increase in the LVOT prosthesis depth PPMI risk increased by 1.41 times (95% CI 1.06–1.87, P = 0.017). In patients with low AVR, ΔPR was higher than in those with higher AVR (33.4 ± 56.7 vs. 12.1 ± 19.4 ms, P = 0.021) and ΔPR was associated to LVOT prosthesis depth ( β = 0.286, P = 0.009). Furthermore, ΔPR was associated with risk of PPMI (OR = 1.03, 95% CI 1.01–1.06, P = 0.024). Conclusions: A low AVR is associated to higher ΔPR and PPMI rates. The correlation between LVOTAbstract: Aims: Preliminary data on Sapien 3 valve (S3-THV) use for transcatheter aortic valve implantation have shown an increased permanent pacemaker implantation (PPMI) rate with respect to Sapien XT valve. Aim of this study was to investigate the role of S3-THV position in the left ventricular outflow tract (LVOT) on electrocardiographic changes suggestive of atrioventricular (ΔPR) and/or intraventricular (ΔQRS) conduction abnormalities and 30 days PPMI rate. Methods and results: Eighty-six consecutive patients treated with S3-THV were included in the study. All patients underwent clinical and electrocardiogram evaluation. Left ventricular outflow tract prosthesis depth was assessed by fluoroscopy and expressed quantitatively (mm) and as aorto-ventricular ratio (AVR). Eight patients (9.3%) needed PPMI at 30 days. A low AVR (≤60/40) predicted PPMI (OR = 6.09, 95% CI 1.19–31.01, P = 0.030) and resulted into higher PPMI rate, compared with higher AVR (30.0 vs. 6.6%, P = 0.017). For each millimetre increase in the LVOT prosthesis depth PPMI risk increased by 1.41 times (95% CI 1.06–1.87, P = 0.017). In patients with low AVR, ΔPR was higher than in those with higher AVR (33.4 ± 56.7 vs. 12.1 ± 19.4 ms, P = 0.021) and ΔPR was associated to LVOT prosthesis depth ( β = 0.286, P = 0.009). Furthermore, ΔPR was associated with risk of PPMI (OR = 1.03, 95% CI 1.01–1.06, P = 0.024). Conclusions: A low AVR is associated to higher ΔPR and PPMI rates. The correlation between LVOT prosthesis depth with ΔPR and higher PPMI rate suggests the need of a careful S3-THV implantation. … (more)
- Is Part Of:
- Europace. Volume 20:Issue 1(2018)
- Journal:
- Europace
- Issue:
- Volume 20:Issue 1(2018)
- Issue Display:
- Volume 20, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 20
- Issue:
- 1
- Issue Sort Value:
- 2018-0020-0001-0000
- Page Start:
- 116
- Page End:
- 123
- Publication Date:
- 2016-10-06
- Subjects:
- Aortic stenosis -- Pacemaker implantation -- Atrioventricular block
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euw310 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12242.xml