A pacemaker lead in the left ventricle: An "unexpected" finding?. Issue 6 (December 2019)
- Record Type:
- Journal Article
- Title:
- A pacemaker lead in the left ventricle: An "unexpected" finding?. Issue 6 (December 2019)
- Main Title:
- A pacemaker lead in the left ventricle: An "unexpected" finding?
- Authors:
- Rovera, Chiara
Golzio, Pier Giorgio
Corgnati, Giuditta
Conti, Valentina
Franco, Erica
Frea, Simone
Moretti, Claudio - Abstract:
- Abstract: Inadvertent malposition of a pacemaker lead in the left ventricle is uncommon, but it should not be misdiagnosed. We report the case of a 68-year-old woman with symptomatic sick-sinus syndrome requiring pacemaker implantation. Shortly afterwards the lead was extracted and a new pacemaker was contralaterally implanted due to pocket hematoma and suspected lead fracture. Three months later, she was referred to our echocardiography laboratory complaining of asthenia. At transthoracic echocardiography an echo-bright linear structure was recognized in left atrium, passing through the mitral valve and leaning against the posterior left ventricular wall. In short-axis and apical views, the lead apparently crossed the interatrial septum through patent foramen ovale. The QRS-paced electrocardiogram showed right bundle branch block morphology. The lead was apparently well positioned, examining the chest X-ray postero-anterior view. On the contrary, by latero-lateral view and left-anterior oblique view, lead curvature was consistent with misplacement into the left ventricle. Malposition was confirmed by transesophageal echocardiography. Given the relatively recent implant, system revision with lead extraction was scheduled and completed without complications. This case report is intended to improve our awareness in the prevention and in the prompt detection of misplaced pacemaker leads in order to manage an immediate correction. <Learning objective: During lead implantation,Abstract: Inadvertent malposition of a pacemaker lead in the left ventricle is uncommon, but it should not be misdiagnosed. We report the case of a 68-year-old woman with symptomatic sick-sinus syndrome requiring pacemaker implantation. Shortly afterwards the lead was extracted and a new pacemaker was contralaterally implanted due to pocket hematoma and suspected lead fracture. Three months later, she was referred to our echocardiography laboratory complaining of asthenia. At transthoracic echocardiography an echo-bright linear structure was recognized in left atrium, passing through the mitral valve and leaning against the posterior left ventricular wall. In short-axis and apical views, the lead apparently crossed the interatrial septum through patent foramen ovale. The QRS-paced electrocardiogram showed right bundle branch block morphology. The lead was apparently well positioned, examining the chest X-ray postero-anterior view. On the contrary, by latero-lateral view and left-anterior oblique view, lead curvature was consistent with misplacement into the left ventricle. Malposition was confirmed by transesophageal echocardiography. Given the relatively recent implant, system revision with lead extraction was scheduled and completed without complications. This case report is intended to improve our awareness in the prevention and in the prompt detection of misplaced pacemaker leads in order to manage an immediate correction. <Learning objective: During lead implantation, fluoroscopic left-anterior oblique view should be always used to ensure correct positioning. At least 3–6 limb leads should be carefully monitored during the procedure, and a 12-lead standard electrocardiogram should be performed shortly afterwards for the paced QRS morphology. Lateral chest X-ray should always be taken after implantation. In cases of doubt, echocardiography (transthoracic or transesophageal) may confirm abnormal lead placement defining the route covered by the catheter.> … (more)
- Is Part Of:
- Journal of cardiology cases. Volume 20:Issue 6(2019)
- Journal:
- Journal of cardiology cases
- Issue:
- Volume 20:Issue 6(2019)
- Issue Display:
- Volume 20, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 6
- Issue Sort Value:
- 2019-0020-0006-0000
- Page Start:
- 228
- Page End:
- 231
- Publication Date:
- 2019-12
- Subjects:
- Pacemaker implantation -- Lead malposition -- Left ventricle -- Echocardiography -- Lead extraction
Cardiology -- Periodicals
Cardiovascular Diseases -- Case Reports
Cardiovascular Diseases -- Periodicals
Cardiology -- Case Reports
Cardiology -- Periodicals
Cardiology
Electronic journals
Periodicals
616.12 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18785409 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/18785409 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jccase.2019.08.012 ↗
- Languages:
- English
- ISSNs:
- 1878-5409
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12221.xml