Successful transcatheter aortic valve implantation for severe aortic stenosis of a bicuspid valve with situs inversus totalis guided by advanced image processing: a case report. Issue 2 (4th May 2018)
- Record Type:
- Journal Article
- Title:
- Successful transcatheter aortic valve implantation for severe aortic stenosis of a bicuspid valve with situs inversus totalis guided by advanced image processing: a case report. Issue 2 (4th May 2018)
- Main Title:
- Successful transcatheter aortic valve implantation for severe aortic stenosis of a bicuspid valve with situs inversus totalis guided by advanced image processing: a case report
- Authors:
- Overtchouk, Pavel
Delhaye, Cédric
Sudre, Arnaud
Modine, Thomas - Abstract:
- Abstract: Introduction: Transcatheter aortic valve implantation (TAVI) can be challenging in case of complex anatomy such as bicuspid aortic valve stenosis or situs inversus. This report illustrates a successful procedure in a patient with both conditions after careful pre-operative planning and per-operative guidance by means of a novel software. Case Presentation: We report the case of a 71-year-old man that presented a type 0 bicuspid aortic valve stenosis and situs inversus. We performed transfemoral TAVI using the Edwards Sapien 3 transcatheter heart valve (THV) and a novel software that provides insight for patient anatomy through computed tomography (CT) extracted three-dimensional reconstruction before the procedure aiming at improving THV positioning during the procedure through fusion of a CT-extracted virtual aortic annulus on the fluoroscopy screen and enhancing of calcifications that can be considered as anatomical landmarks. The Edwards Sapien 3 THV was accurately implanted in a supra-annular fashion. Post-operative echocardiography showed an excellent result without any para-prosthetic leak, and the patient reported symptom improvement. Discussion: During TAVI the angiographic appearance of the cusps of a bicuspid aortic valve is irregular and asymmetric, which can lead to malpositioning, paravalvular regurgitation, and increased rates of pacemaker implantation after TAVI. Furthermore, usual anatomical landmarks can be even more disturbed by the situs inversusAbstract: Introduction: Transcatheter aortic valve implantation (TAVI) can be challenging in case of complex anatomy such as bicuspid aortic valve stenosis or situs inversus. This report illustrates a successful procedure in a patient with both conditions after careful pre-operative planning and per-operative guidance by means of a novel software. Case Presentation: We report the case of a 71-year-old man that presented a type 0 bicuspid aortic valve stenosis and situs inversus. We performed transfemoral TAVI using the Edwards Sapien 3 transcatheter heart valve (THV) and a novel software that provides insight for patient anatomy through computed tomography (CT) extracted three-dimensional reconstruction before the procedure aiming at improving THV positioning during the procedure through fusion of a CT-extracted virtual aortic annulus on the fluoroscopy screen and enhancing of calcifications that can be considered as anatomical landmarks. The Edwards Sapien 3 THV was accurately implanted in a supra-annular fashion. Post-operative echocardiography showed an excellent result without any para-prosthetic leak, and the patient reported symptom improvement. Discussion: During TAVI the angiographic appearance of the cusps of a bicuspid aortic valve is irregular and asymmetric, which can lead to malpositioning, paravalvular regurgitation, and increased rates of pacemaker implantation after TAVI. Furthermore, usual anatomical landmarks can be even more disturbed by the situs inversus totalis. We believe that pre-operative three-dimensional reconstruction and per-operative fluoroscopy image processing, provided by software such as the one presented in this case report, can provide precious guidance for TAVI in patients with complex and unusual anatomy. … (more)
- Is Part Of:
- European heart journal. Volume 2:Issue 2(2018)
- Journal:
- European heart journal
- Issue:
- Volume 2:Issue 2(2018)
- Issue Display:
- Volume 2, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 2
- Issue:
- 2
- Issue Sort Value:
- 2018-0002-0002-0000
- Page Start:
- 1
- Page End:
- 4
- Publication Date:
- 2018-05-04
- Subjects:
- TAVI -- TAVR -- Image processing -- Situs inversus -- Bicuspid -- Case report
Cardiology -- Periodicals
Cardiology -- Case studies -- Periodicals
Heart -- Diseases -- Periodicals
Heart -- Diseases -- Case studies -- Periodicals
616.12 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/ehjcr/ ↗ - DOI:
- 10.1093/ehjcr/yty049 ↗
- Languages:
- English
- ISSNs:
- 2514-2119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12217.xml