Cardiac resynchronization therapy and electrical storm: results of the OBSERVational registry on long-term outcome of ICD patients (OBSERVO-ICD). Issue 6 (7th June 2017)
- Record Type:
- Journal Article
- Title:
- Cardiac resynchronization therapy and electrical storm: results of the OBSERVational registry on long-term outcome of ICD patients (OBSERVO-ICD). Issue 6 (7th June 2017)
- Main Title:
- Cardiac resynchronization therapy and electrical storm: results of the OBSERVational registry on long-term outcome of ICD patients (OBSERVO-ICD)
- Authors:
- Guerra, Federico
Palmisano, Pietro
Dell'Era, Gabriele
Ziacchi, Matteo
Ammendola, Ernesto
Pongetti, Giulia
Bonelli, Paolo
Patani, Francesca
Devecchi, Chiara
Accogli, Michele
Occhetta, Eraldo
Nigro, Gerardo
Biffi, Mauro
Boriani, Giuseppe
Capucci, Alessandro - Abstract:
- Abstract: Aims: Electrical storm (ES) is a condition defined as three or more episodes of ventricular fibrillation (VF) or ventricular tachycardia (VT) within 24 h, and usually coexist with advanced heart failure in patients with structural heart disease. The aim of the present study is to test whether cardiac resynchronization therapy (CRT) can be associated with a lower incidence of ES. Methods and results: The OBSERVO-ICD (NCT02735811) is a multicentre, retrospective registry, enrolling all consecutive patients undergoing ICD or CRT-D implantation from 2010 to 2012 in five Italian high-volume arrhythmia centres. Propensity score matching was used to compare two equally sized cohorts of ICD and CRT-D patients with similar characteristics. The primary endpoint was the time free from ES. Secondary endpoints were time free from unclustered VT/VF episodes and time free from ES in CRT-D patients according to clinical or echographic response. CRT-D was associated with a 45% relative risk reduction in ES when compared with ICD (5.6% vs. 12.3%; log rank P = 0.014). CRT-responders presented lower rates of ES when compared with non-responders and negative responders according to both clinical and echographic criteria (log-rank P = 0.017 and 0.023, respectively). No ES was detected in any of the 133 full responders to CRT-D. Clinical and echographic positive responses, but not CRT-implant per se, were associated with lower estimate rates of unclustered VTs/VFs. Conclusion: PatientsAbstract: Aims: Electrical storm (ES) is a condition defined as three or more episodes of ventricular fibrillation (VF) or ventricular tachycardia (VT) within 24 h, and usually coexist with advanced heart failure in patients with structural heart disease. The aim of the present study is to test whether cardiac resynchronization therapy (CRT) can be associated with a lower incidence of ES. Methods and results: The OBSERVO-ICD (NCT02735811) is a multicentre, retrospective registry, enrolling all consecutive patients undergoing ICD or CRT-D implantation from 2010 to 2012 in five Italian high-volume arrhythmia centres. Propensity score matching was used to compare two equally sized cohorts of ICD and CRT-D patients with similar characteristics. The primary endpoint was the time free from ES. Secondary endpoints were time free from unclustered VT/VF episodes and time free from ES in CRT-D patients according to clinical or echographic response. CRT-D was associated with a 45% relative risk reduction in ES when compared with ICD (5.6% vs. 12.3%; log rank P = 0.014). CRT-responders presented lower rates of ES when compared with non-responders and negative responders according to both clinical and echographic criteria (log-rank P = 0.017 and 0.023, respectively). No ES was detected in any of the 133 full responders to CRT-D. Clinical and echographic positive responses, but not CRT-implant per se, were associated with lower estimate rates of unclustered VTs/VFs. Conclusion: Patients with CRT had a lower incidence of ES when compared with propensity-matched ICD patients. The long-term benefit of CRT seems to be due to the improved haemodynamics, as CRT-responders performed markedly better over a long-term follow-up. … (more)
- Is Part Of:
- Europace. Volume 20:Issue 6(2018)
- Journal:
- Europace
- Issue:
- Volume 20:Issue 6(2018)
- Issue Display:
- Volume 20, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 20
- Issue:
- 6
- Issue Sort Value:
- 2018-0020-0006-0000
- Page Start:
- 979
- Page End:
- 985
- Publication Date:
- 2017-06-07
- Subjects:
- Cardiac resynchronization therapy -- Implantable cardioverter-defibrillator -- Electrical storm -- Heart failure -- Ventricular fibrillation -- Ventricular tachycardia
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/eux166 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12209.xml