Comparative performance of transcatheter aortic valve-in-valve implantation versus conventional surgical redo aortic valve replacement in patients with degenerated aortic valve bioprostheses: systematic review and meta-analysis. (4th October 2017)
- Record Type:
- Journal Article
- Title:
- Comparative performance of transcatheter aortic valve-in-valve implantation versus conventional surgical redo aortic valve replacement in patients with degenerated aortic valve bioprostheses: systematic review and meta-analysis. (4th October 2017)
- Main Title:
- Comparative performance of transcatheter aortic valve-in-valve implantation versus conventional surgical redo aortic valve replacement in patients with degenerated aortic valve bioprostheses: systematic review and meta-analysis
- Authors:
- Gozdek, Mirosław
Raffa, Giuseppe Maria
Suwalski, Piotr
Kołodziejczak, Michalina
Anisimowicz, Lech
Kubica, Jacek
Navarese, Eliano Pio
Kowalewski, Mariusz - Abstract:
- Summary: The objective of this report was to directly compare, by means of a systematic review and meta-analysis, redo surgical aortic valve replacement (re-sAVR) with valve-in-valve transcatheter aortic valve implantation (ViV TAVI) for patients with failed degenerated aortic bioprostheses. Multiple databases were screened for all available reports comparing ViV TAVI with re-sAVR in patients with failing degenerated aortic bioprostheses. The primary outcome was all-cause mortality determined from the longest available survival data. Five observational studies ( n = 342) were included in the meta-analysis; patients in the ViV TAVI group were older and had a higher baseline risk compared to those in the re-sAVR group. Although there was no statistical difference in procedural mortality [risk ratio (RR) 0.74, 95% confidence interval (CI) 0.18–2.97; P = 0.67], 30-day mortality (RR 1.29, 95% CI 0.44–3.78; P = 0.64) and cardiovascular mortality (RR 0.91, 95% CI 0.30–2.70; P = 0.86) at a mean follow-up period of 18 months, cumulative survival analysis favoured surgery with borderline statistical significance (ViV TAVI versus re-sAVR: hazard ratio 1.91, 95% CI 1.03–3.57; P = 0.039). ViV TAVI was associated with a significantly lower rate of permanent pacemaker implantations (RR 0.37, 95% CI 0.20–0.68; P = 0.002) and shorter intensive care unit ( P < 0.001) and hospital stays ( P = 0.020). In contrast, re-sAVR offered superior echocardiographic outcomes: lowerSummary: The objective of this report was to directly compare, by means of a systematic review and meta-analysis, redo surgical aortic valve replacement (re-sAVR) with valve-in-valve transcatheter aortic valve implantation (ViV TAVI) for patients with failed degenerated aortic bioprostheses. Multiple databases were screened for all available reports comparing ViV TAVI with re-sAVR in patients with failing degenerated aortic bioprostheses. The primary outcome was all-cause mortality determined from the longest available survival data. Five observational studies ( n = 342) were included in the meta-analysis; patients in the ViV TAVI group were older and had a higher baseline risk compared to those in the re-sAVR group. Although there was no statistical difference in procedural mortality [risk ratio (RR) 0.74, 95% confidence interval (CI) 0.18–2.97; P = 0.67], 30-day mortality (RR 1.29, 95% CI 0.44–3.78; P = 0.64) and cardiovascular mortality (RR 0.91, 95% CI 0.30–2.70; P = 0.86) at a mean follow-up period of 18 months, cumulative survival analysis favoured surgery with borderline statistical significance (ViV TAVI versus re-sAVR: hazard ratio 1.91, 95% CI 1.03–3.57; P = 0.039). ViV TAVI was associated with a significantly lower rate of permanent pacemaker implantations (RR 0.37, 95% CI 0.20–0.68; P = 0.002) and shorter intensive care unit ( P < 0.001) and hospital stays ( P = 0.020). In contrast, re-sAVR offered superior echocardiographic outcomes: lower incidence of patient–prosthesis mismatch ( P = 0.008), fewer paravalvular leaks ( P = 0.023) and lower mean postoperative aortic valve gradients in the prespecified analysis ( P = 0.017). The ViV TAVI approach is a safe and feasible alternative to re-sAVR that may offer an effective, less invasive treatment for patients with failed surgical aortic valve bioprostheses who are inoperable or at high risk. Re-sAVR should remain the standard of care, particularly in the low-risk population, because it offers superior haemodynamic outcomes with low mortality rates. … (more)
- Is Part Of:
- European journal of cardio-thoracic surgery. Volume 53:Number 3(2018)
- Journal:
- European journal of cardio-thoracic surgery
- Issue:
- Volume 53:Number 3(2018)
- Issue Display:
- Volume 53, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 53
- Issue:
- 3
- Issue Sort Value:
- 2018-0053-0003-0000
- Page Start:
- 495
- Page End:
- 504
- Publication Date:
- 2017-10-04
- Subjects:
- Aortic valve -- Bioprosthesis -- Valve-in-valve -- Aortic valve replacement -- Transcatheter aortic valve implantation -- Meta-analysis
Heart -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
617.54 - Journal URLs:
- http://ejcts.oxfordjournals.org/ ↗
http://www.sciencedirect.com/science/journal/10107940 ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ejcts/ezx347 ↗
- Languages:
- English
- ISSNs:
- 1010-7940
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.725620
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12205.xml