Diagnostic Accuracy of Ultrasonography in the Detection of Postsurgical Recurrence in Crohn's Disease: A Systematic Review with Meta-analysis. Issue 5 (23rd April 2018)
- Record Type:
- Journal Article
- Title:
- Diagnostic Accuracy of Ultrasonography in the Detection of Postsurgical Recurrence in Crohn's Disease: A Systematic Review with Meta-analysis. Issue 5 (23rd April 2018)
- Main Title:
- Diagnostic Accuracy of Ultrasonography in the Detection of Postsurgical Recurrence in Crohn's Disease: A Systematic Review with Meta-analysis
- Authors:
- Rispo, Antonio
Imperatore, Nicola
Testa, Anna
Nardone, Olga Maria
Luglio, Gaetano
Caporaso, Nicola
Castiglione, Fabiana - Abstract:
- Abstract: Background and aims: The postoperative course of Crohn's disease (CD) is best predicted by ileocolonoscopy. Ultrasonography (US) has been proposed as indicator for postsurgical recurrence (PSR), but further confirmation is needed. We performed a systemic review with meta-analysis to assess the pooled diagnostic accuracy of US in the evaluation of PSR. Methods: The systematic review was performed in PubMed/MEDLINE, EMBASE, SCOPUS, and Cochrane databases to identify studies assessing the US accuracy in PSR diagnosis. A sub-analysis between bowel sonography (BS), small-intestine contrast ultrasound (SICUS), and contrast-enhanced ultrasound (CEUS) was performed. Pooling was performed using diagnostic fixed or random-effect model according with heterogeneity. Results: Ten studies (536 patients) met the inclusion criteria. There was no publication bias. Pooled sensitivity and specificity of US in detecting PSR were 0.94 (95% CI, 0.86–0.97) and 0.84 (95% CI, 0.62–0.94; diagnostic accuracy 90%), respectively. At sub-analysis, pooled sensitivity and specificity were 0.82 (95% CI, 0.76–0.88) and 0.88 (95% CI, 0.74–0.95) respectively for BS, with 0.99 (95% CI, 0.99–1.00) and 0.74 (95% CI, 0.73–0.74) for SICUS. Finally, an SROC curve was built to establish the best bowel wall thickness (BWT) cutoff able to predict the presence of severe PSR (Rutgeerts ≥3): a BWT ≥5.5 mm at US revealed sensitivity of 83.8% (95% CI, 73.6%–90.6%), specificity of 97.7% (95% CI, 93%–99%).Abstract: Background and aims: The postoperative course of Crohn's disease (CD) is best predicted by ileocolonoscopy. Ultrasonography (US) has been proposed as indicator for postsurgical recurrence (PSR), but further confirmation is needed. We performed a systemic review with meta-analysis to assess the pooled diagnostic accuracy of US in the evaluation of PSR. Methods: The systematic review was performed in PubMed/MEDLINE, EMBASE, SCOPUS, and Cochrane databases to identify studies assessing the US accuracy in PSR diagnosis. A sub-analysis between bowel sonography (BS), small-intestine contrast ultrasound (SICUS), and contrast-enhanced ultrasound (CEUS) was performed. Pooling was performed using diagnostic fixed or random-effect model according with heterogeneity. Results: Ten studies (536 patients) met the inclusion criteria. There was no publication bias. Pooled sensitivity and specificity of US in detecting PSR were 0.94 (95% CI, 0.86–0.97) and 0.84 (95% CI, 0.62–0.94; diagnostic accuracy 90%), respectively. At sub-analysis, pooled sensitivity and specificity were 0.82 (95% CI, 0.76–0.88) and 0.88 (95% CI, 0.74–0.95) respectively for BS, with 0.99 (95% CI, 0.99–1.00) and 0.74 (95% CI, 0.73–0.74) for SICUS. Finally, an SROC curve was built to establish the best bowel wall thickness (BWT) cutoff able to predict the presence of severe PSR (Rutgeerts ≥3): a BWT ≥5.5 mm at US revealed sensitivity of 83.8% (95% CI, 73.6%–90.6%), specificity of 97.7% (95% CI, 93%–99%). Conclusions: US shows high sensitivity and specificity for the diagnosis of PSR. SICUS appears more sensitive—but less specific—than BS, while the role of CEUS needs further investigation. A cutoff value of BWT ≥5.5 mm is strongly indicative of severe PSR. … (more)
- Is Part Of:
- Inflammatory bowel diseases. Volume 24:Issue 5(2018)
- Journal:
- Inflammatory bowel diseases
- Issue:
- Volume 24:Issue 5(2018)
- Issue Display:
- Volume 24, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 24
- Issue:
- 5
- Issue Sort Value:
- 2018-0024-0005-0000
- Page Start:
- 977
- Page End:
- 988
- Publication Date:
- 2018-04-23
- Subjects:
- bowel sonography -- CEUS -- Crohn's disease -- postsurgical recurrence -- SICUS -- ultrasonography
Inflammatory bowel diseases -- Periodicals
Colitis, Ulcerative -- Periodicals
Crohn Disease -- Periodicals
Inflammatory Bowel Diseases -- Periodicals
616.344 - Journal URLs:
- http://journals.lww.com/ibdjournal/pages/default.aspx ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1536-4844/ ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=ovft&AN=00054725-000000000-00000 ↗
https://academic.oup.com/ibdjournal ↗
http://journals.lww.com ↗ - DOI:
- 10.1093/ibd/izy012 ↗
- Languages:
- English
- ISSNs:
- 1078-0998
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4478.845400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12210.xml