Carotid stenosis with impaired brain flow reserve is associated with an increased risk of stroke in on-pump cardiovascular surgery. (26th February 2018)
- Record Type:
- Journal Article
- Title:
- Carotid stenosis with impaired brain flow reserve is associated with an increased risk of stroke in on-pump cardiovascular surgery. (26th February 2018)
- Main Title:
- Carotid stenosis with impaired brain flow reserve is associated with an increased risk of stroke in on-pump cardiovascular surgery
- Authors:
- Tsuda, Kazumasa
Shiiya, Norihiko
Washiyama, Naoki
Yamashita, Katsushi
Ohkura, Kazuhiro
Takahashi, Daisuke
Kando, Yumi
Natsume, Kayoko
Yamanaka, Ken
Takeuchi, Yuki - Abstract:
- Abstract: OBJECTIVES: To prevent haemodynamic stroke during cardiovascular surgery in patients with carotid stenosis, we routinely evaluated magnetic resonance angiography and selectively evaluated brain perfusion single-photon emission computed tomography with acetazolamide challenge. Off-pump surgery was preferred when cerebral blood flow reserve was impaired. This strategy's usefulness was investigated. METHODS: Among the 1059 consecutive patients who underwent preoperative carotid screening by magnetic resonance angiography, 84 (7.9%) patients had >50% stenosis; 45 of them underwent brain single-photon emission computed tomography. The severity of cerebral blood flow compromise was estimated by the proportion of Stage 2 area in the affected territory, in which both resting blood flow (<32 ml/min) and flow reserve (<10%) were reduced. RESULTS: Perioperative stroke occurred in 1.7% overall (18/1059), in 6% (5/84) of those with carotid stenosis and in 1.3% (13/975) of those without stenosis ( P = 0.010). On subgroup analysis, carotid stenosis was associated with an increased risk of stroke in the on-pump surgery group [ n = 949, 5/59 (9%) with stenosis vs 11/890 (1.1%) without stenosis, P = 0.002], while it was not in the off-pump group [ n = 110, 0/25 (0%) with stenosis vs 2/85 (2%) without stenosis, P = 0.59]. With respect to the role of acetazolamide single-photon emission computed tomography, 2 of the 4 patients with Stage 2 area >10% undergoing on-pump surgeryAbstract: OBJECTIVES: To prevent haemodynamic stroke during cardiovascular surgery in patients with carotid stenosis, we routinely evaluated magnetic resonance angiography and selectively evaluated brain perfusion single-photon emission computed tomography with acetazolamide challenge. Off-pump surgery was preferred when cerebral blood flow reserve was impaired. This strategy's usefulness was investigated. METHODS: Among the 1059 consecutive patients who underwent preoperative carotid screening by magnetic resonance angiography, 84 (7.9%) patients had >50% stenosis; 45 of them underwent brain single-photon emission computed tomography. The severity of cerebral blood flow compromise was estimated by the proportion of Stage 2 area in the affected territory, in which both resting blood flow (<32 ml/min) and flow reserve (<10%) were reduced. RESULTS: Perioperative stroke occurred in 1.7% overall (18/1059), in 6% (5/84) of those with carotid stenosis and in 1.3% (13/975) of those without stenosis ( P = 0.010). On subgroup analysis, carotid stenosis was associated with an increased risk of stroke in the on-pump surgery group [ n = 949, 5/59 (9%) with stenosis vs 11/890 (1.1%) without stenosis, P = 0.002], while it was not in the off-pump group [ n = 110, 0/25 (0%) with stenosis vs 2/85 (2%) without stenosis, P = 0.59]. With respect to the role of acetazolamide single-photon emission computed tomography, 2 of the 4 patients with Stage 2 area >10% undergoing on-pump surgery without preceding carotid revascularization developed stroke, while none of the 21 patients with Stage 2 area <10% undergoing on-pump surgery developed stroke ( P = 0.020). CONCLUSIONS: Carotid stenosis is a risk factor for perioperative stroke in on-pump surgery. Patients with large Stage 2 area (>10%) are at increased risk of perioperative stroke when on-pump surgery is performed. … (more)
- Is Part Of:
- Interactive cardiovascular and thoracic surgery. Volume 27:Number 1(2018)
- Journal:
- Interactive cardiovascular and thoracic surgery
- Issue:
- Volume 27:Number 1(2018)
- Issue Display:
- Volume 27, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 27
- Issue:
- 1
- Issue Sort Value:
- 2018-0027-0001-0000
- Page Start:
- 75
- Page End:
- 80
- Publication Date:
- 2018-02-26
- Subjects:
- Brain ischaemia -- Carotid artery stenosis -- Cardiovascular surgery -- Brain perfusion single-photon emission computed tomography -- Acetazolamide
Chest -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
616.1 - Journal URLs:
- http://icvts.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/icvts/ivy049 ↗
- Languages:
- English
- ISSNs:
- 1569-9293
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4531.871920
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: