Impact of the bicuspid aortic valve on aortic root haemodynamics: three-dimensional computed fluid dynamics simulation. (22nd March 2018)
- Record Type:
- Journal Article
- Title:
- Impact of the bicuspid aortic valve on aortic root haemodynamics: three-dimensional computed fluid dynamics simulation. (22nd March 2018)
- Main Title:
- Impact of the bicuspid aortic valve on aortic root haemodynamics: three-dimensional computed fluid dynamics simulation
- Authors:
- Berdajs, Denis
Mosbahi, Selim
Eckstein, Friedrich S
Charbonnier, Dominique
Ferrari, Enrico
von Segesser, Ludwig K - Abstract:
- Abstract: OBJECTIVES: The aim was to evaluate the impact of a bicuspid aortic valve (BAV) on local shear stress and on the pressure profile on the elements of the aortic root (AoR). METHODS: The experiment setup included a BAV with aortic valve stenosis ( n = 5 pigs, 67 ± 3.5 kg) and insufficiency ( n = 5 pigs, 66.7 ± 4.4 kg). By implanting 6 high-fidelity microsonometric crystals in each AoR, we determined the 3-dimensional (3D) geometry of the AoR. Experimental and geometric data were used to create a 3D time- and pressure-dependent computed fluid dynamic model of the AoR with the BAV. RESULTS: 3D AoR geometry was determined by AoR tilt ( α ) and rotation angle ( β ). Both values were maximal at the end of diastole: 24.41 ± 1.70° ( α ) and 20.90 ± 2.11° ( β ) for BAV with stenosis and 31.92 ± 11.51° ( α ) and 20.84 ± 9.80° ( β ) for BAV with insufficiency and minimal at peak ejection 23.42 ± 1.65° ( α ), 20.38 ± 1.61° ( β ) for stenosis and 26.62 ± 7.86° ( α ), 19.79 ± 8.45° ( β ) for insufficiency. In insufficiency, low shear stress of 0–0.08 Pa and moderate pressure (60–80 mmHg) were present. In BAV with stenosis, low shear stress of 0–0.5 Pa and moderate pressure (0–20 mmHg) were present at diastole; at peak ejection high shear stress >2 Pa and elevated pressure of >80 mmHg were present. CONCLUSIONS: In a BAV with aortic valve stenosis, the haemodynamics are less favourable. The elevated pressure with elevated shear stress may over the long term promote degenerativeAbstract: OBJECTIVES: The aim was to evaluate the impact of a bicuspid aortic valve (BAV) on local shear stress and on the pressure profile on the elements of the aortic root (AoR). METHODS: The experiment setup included a BAV with aortic valve stenosis ( n = 5 pigs, 67 ± 3.5 kg) and insufficiency ( n = 5 pigs, 66.7 ± 4.4 kg). By implanting 6 high-fidelity microsonometric crystals in each AoR, we determined the 3-dimensional (3D) geometry of the AoR. Experimental and geometric data were used to create a 3D time- and pressure-dependent computed fluid dynamic model of the AoR with the BAV. RESULTS: 3D AoR geometry was determined by AoR tilt ( α ) and rotation angle ( β ). Both values were maximal at the end of diastole: 24.41 ± 1.70° ( α ) and 20.90 ± 2.11° ( β ) for BAV with stenosis and 31.92 ± 11.51° ( α ) and 20.84 ± 9.80° ( β ) for BAV with insufficiency and minimal at peak ejection 23.42 ± 1.65° ( α ), 20.38 ± 1.61° ( β ) for stenosis and 26.62 ± 7.86° ( α ), 19.79 ± 8.45° ( β ) for insufficiency. In insufficiency, low shear stress of 0–0.08 Pa and moderate pressure (60–80 mmHg) were present. In BAV with stenosis, low shear stress of 0–0.5 Pa and moderate pressure (0–20 mmHg) were present at diastole; at peak ejection high shear stress >2 Pa and elevated pressure of >80 mmHg were present. CONCLUSIONS: In a BAV with aortic valve stenosis, the haemodynamics are less favourable. The elevated pressure with elevated shear stress may over the long term promote degenerative processes in the leaflets and consequently valve function failure. … (more)
- Is Part Of:
- Interactive cardiovascular and thoracic surgery. Volume 27:Number 3(2018)
- Journal:
- Interactive cardiovascular and thoracic surgery
- Issue:
- Volume 27:Number 3(2018)
- Issue Display:
- Volume 27, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 27
- Issue:
- 3
- Issue Sort Value:
- 2018-0027-0003-0000
- Page Start:
- 446
- Page End:
- 454
- Publication Date:
- 2018-03-22
- Subjects:
- Aortic valve stenosis -- Aortic valve insufficiency -- Aortic root -- Computed fluid dynamic simulation
Chest -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
616.1 - Journal URLs:
- http://icvts.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/icvts/ivy044 ↗
- Languages:
- English
- ISSNs:
- 1569-9293
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4531.871920
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12201.xml