Geometric changes in the aortic valve annulus during the cardiac cycle: impact on aortic valve repair. (5th March 2018)
- Record Type:
- Journal Article
- Title:
- Geometric changes in the aortic valve annulus during the cardiac cycle: impact on aortic valve repair. (5th March 2018)
- Main Title:
- Geometric changes in the aortic valve annulus during the cardiac cycle: impact on aortic valve repair
- Authors:
- Petersen, Johannes
Voigtländer, Lisa
Schofer, Niklas
Neumann, Niklas
von Kodolitsch, Yskert
Reichenspurner, Hermann
Girdauskas, Evaldas - Abstract:
- Abstract: OBJECTIVES: The growing experience in aortic valve (AV) repair showed that annular stabilization is a crucial component to achieve stable long-term results after AV repair. Dynamic changes in the AV annulus during the cardiac cycle may have an impact on annuloplasty design. METHODS: We retrospectively analysed full cardiac cycle multislice computed tomography data from 58 consecutive patients (mean age 75.9 ± 6.5 years, 36% men) with normally functioning tricuspid AVs (normal AV subgroup). The following computed tomography parameters were measured during systole and diastole: maximum, minimum and mean AV annulus diameter, AV annular area and AV annular perimeter. The AV annular eccentricity index was calculated (%) [(max AV annulus × 100/min AV annulus) – 100] in systole and diastole. Subsequently, multislice computed tomography data from 20 patients with severe aortic regurgitation were analysed [aortic valve regurgitation (AR) subgroup]. RESULTS: In the normal AV subgroup, there was a significant decrease in the mean AV annulus diameter from systole to diastole (i.e. 24.6 ± 2.5 mm vs 23.9 ± 2.4 mm, respectively; P < 0.001), which occurred predominantly in the short annular axis (i.e. 21.2 ± 2.4 mm in systole vs 19.9 ± 2.3 mm in diastole; P < 0.001). The mean AV annular area decreased significantly in diastole (i.e. 467.5 ± 94.5 mm 2 in systole vs 444.8 ± 86.1 mm 2 in diastole; P = 0.012). The annular eccentricity index increased significantly in diastoleAbstract: OBJECTIVES: The growing experience in aortic valve (AV) repair showed that annular stabilization is a crucial component to achieve stable long-term results after AV repair. Dynamic changes in the AV annulus during the cardiac cycle may have an impact on annuloplasty design. METHODS: We retrospectively analysed full cardiac cycle multislice computed tomography data from 58 consecutive patients (mean age 75.9 ± 6.5 years, 36% men) with normally functioning tricuspid AVs (normal AV subgroup). The following computed tomography parameters were measured during systole and diastole: maximum, minimum and mean AV annulus diameter, AV annular area and AV annular perimeter. The AV annular eccentricity index was calculated (%) [(max AV annulus × 100/min AV annulus) – 100] in systole and diastole. Subsequently, multislice computed tomography data from 20 patients with severe aortic regurgitation were analysed [aortic valve regurgitation (AR) subgroup]. RESULTS: In the normal AV subgroup, there was a significant decrease in the mean AV annulus diameter from systole to diastole (i.e. 24.6 ± 2.5 mm vs 23.9 ± 2.4 mm, respectively; P < 0.001), which occurred predominantly in the short annular axis (i.e. 21.2 ± 2.4 mm in systole vs 19.9 ± 2.3 mm in diastole; P < 0.001). The mean AV annular area decreased significantly in diastole (i.e. 467.5 ± 94.5 mm 2 in systole vs 444.8 ± 86.1 mm 2 in diastole; P = 0.012). The annular eccentricity index increased significantly in diastole (33.0 ± 12.2% in systole vs 41.4 ± 13.5% in diastole; P < 0.001). Furthermore, we found an inverse linear correlation between the mean AV annulus diameter and the annular eccentricity index ( r = −0.40, P = 0.034). The diastolic annular eccentricity index was significantly reduced in the AR subgroup (i.e. 41.4 ± 13.5% in the normal AV subgroup vs 33.7 ± 14.8% in the AR cohort; P = 0.035). CONCLUSIONS: The normal AV annulus undergoes important geometric deformation during the cardiac cycle that is significantly reduced in diastole in the AR scenario. A novel AV annuloplasty system should ideally adapt for this marked diastolic annular eccentricity and thereby allow for dynamic aortic root changes during the cardiac cycle. … (more)
- Is Part Of:
- European journal of cardio-thoracic surgery. Volume 54:Number 3(2018)
- Journal:
- European journal of cardio-thoracic surgery
- Issue:
- Volume 54:Number 3(2018)
- Issue Display:
- Volume 54, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 54
- Issue:
- 3
- Issue Sort Value:
- 2018-0054-0003-0000
- Page Start:
- 441
- Page End:
- 445
- Publication Date:
- 2018-03-05
- Subjects:
- Annulus -- Aortic valve -- Annuloplasty -- Aortic valve repair -- Full cardiac cycle
Heart -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
617.54 - Journal URLs:
- http://ejcts.oxfordjournals.org/ ↗
http://www.sciencedirect.com/science/journal/10107940 ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ejcts/ezy099 ↗
- Languages:
- English
- ISSNs:
- 1010-7940
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.725620
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12201.xml