Randomized comparison of sirolimus eluting, and biolimus eluting bioresorbable polymer stents: the SORT-OUT VII optical coherence tomography study. (28th March 2017)
- Record Type:
- Journal Article
- Title:
- Randomized comparison of sirolimus eluting, and biolimus eluting bioresorbable polymer stents: the SORT-OUT VII optical coherence tomography study. (28th March 2017)
- Main Title:
- Randomized comparison of sirolimus eluting, and biolimus eluting bioresorbable polymer stents: the SORT-OUT VII optical coherence tomography study
- Authors:
- Andreasen, Lene N
Holm, Niels R
Balleby, Ida R
Krusell, Lars R
Maeng, Michael
Jakobsen, Lars
Veien, Karsten T
Hansen, Knud N
Kristensen, Steen D
Hjort, Jakob
Kaltoft, Anne
Dijkstra, Jouke
Terkelsen, Christian J
Lassen, Jens F
Madsen, Morten
Bøtker, Hans Erik
Jensen, Lisette O
Christiansen, Evald H - Abstract:
- Abstract: Aims: To show non-inferiority of the 67- or 87 µm thick, sirolimus-eluting Orsiro drug eluting stent (DES) to the 122 µm thick, biolimus-eluting Nobori DES regarding size of vessel lumen outside the stent at 13-month follow-up. Methods and results: This study was a substudy to the SORT-OUT VII trial, a prospective, 1:1-randomized, comparison of the two stents in patients with stable coronary artery disease or acute coronary syndrome. Optical coherence tomography was acquired after percutaneous coronary intervention and at 13-month follow-up. The substudy was powered to access non-inferiority (Δ = 0.60 mm 2 ) of the Orsiro DES to the Nobori DES for the primary endpoint of mean extra stent lumen (ESL) i.e. vessel lumen outside the stent at 13-month follow-up. We randomized 124 patients to Orsiro ( n = 60) or Nobori ( n = 64). Due to a difference in the one-sided 95%-confidence interval of 0.26 mm 2, but increased to 0.82 mm 2 after appropriate log-transformation, it could not be rejected that Orsiro exceeded the non-inferiority limit. Testing for superiority, Orsiro had a significantly larger mean ESL at follow-up (Orsiro: 0.11 mm 2 [0.02;0.30] mm 2, Nobori: 0.03 mm 2 [0.00;0.17] mm 2, P = 0.04). Stent strut coverage was, Orsiro: 97.6 % [93.8;99.4]%, and Nobori: 96.3 % [90.5;98, 6]% ( P = 0.13). Conclusion: Orsiro DES had a significantly larger mean ESL at follow-up and it could not be excluded that Orsiro exceeded the limit for non-inferiority. Nobori DES had a moreAbstract: Aims: To show non-inferiority of the 67- or 87 µm thick, sirolimus-eluting Orsiro drug eluting stent (DES) to the 122 µm thick, biolimus-eluting Nobori DES regarding size of vessel lumen outside the stent at 13-month follow-up. Methods and results: This study was a substudy to the SORT-OUT VII trial, a prospective, 1:1-randomized, comparison of the two stents in patients with stable coronary artery disease or acute coronary syndrome. Optical coherence tomography was acquired after percutaneous coronary intervention and at 13-month follow-up. The substudy was powered to access non-inferiority (Δ = 0.60 mm 2 ) of the Orsiro DES to the Nobori DES for the primary endpoint of mean extra stent lumen (ESL) i.e. vessel lumen outside the stent at 13-month follow-up. We randomized 124 patients to Orsiro ( n = 60) or Nobori ( n = 64). Due to a difference in the one-sided 95%-confidence interval of 0.26 mm 2, but increased to 0.82 mm 2 after appropriate log-transformation, it could not be rejected that Orsiro exceeded the non-inferiority limit. Testing for superiority, Orsiro had a significantly larger mean ESL at follow-up (Orsiro: 0.11 mm 2 [0.02;0.30] mm 2, Nobori: 0.03 mm 2 [0.00;0.17] mm 2, P = 0.04). Stent strut coverage was, Orsiro: 97.6 % [93.8;99.4]%, and Nobori: 96.3 % [90.5;98, 6]% ( P = 0.13). Conclusion: Orsiro DES had a significantly larger mean ESL at follow-up and it could not be excluded that Orsiro exceeded the limit for non-inferiority. Nobori DES had a more heterogeneous distribution of neointima but stent strut coverage did not differ significantly between the two stents. … (more)
- Is Part Of:
- European heart journal. Volume 19:Number 3(2018)
- Journal:
- European heart journal
- Issue:
- Volume 19:Number 3(2018)
- Issue Display:
- Volume 19, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 19
- Issue:
- 3
- Issue Sort Value:
- 2018-0019-0003-0000
- Page Start:
- 329
- Page End:
- 338
- Publication Date:
- 2017-03-28
- Subjects:
- drug-eluting stents -- bioresorbable polymer stents -- optical coherence tomography
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jex035 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12187.xml